المعاملات الرئيسية

Measuring range
0.01 to 25% O2 (XZR501 GP analyzer ranged 0…25% O2)
Accuracy
Better than ±2% of reading; repeatability ±0.1%; linearity better than ±1%; drift <1% per month
Output
One 0/4–20 mA linear galvanically isolated output; optional 2nd mA (O2 or calculated CO2); optional RS485
Supply
110 V (100…120) or 220 V (190…240) 50/60 Hz
Protection
Sensor head IP53; control unit IP52
Ambient temperature
0 to +55 °C (+32 to +131 °F); humidity 5…90% RH non-condensing
تنزيل ورقة المواصفات PDF
المعاملالقيمة
Measuring range0.01 to 25% O2 (XZR501 GP analyzer ranged 0…25% O2)
AccuracyBetter than ±2% of reading; repeatability ±0.1%; linearity better than ±1%; drift <1% per month
OutputOne 0/4–20 mA linear galvanically isolated output; optional 2nd mA (O2 or calculated CO2); optional RS485
Supply110 V (100…120) or 220 V (190…240) 50/60 Hz
ProtectionSensor head IP53; control unit IP52
Ambient temperature0 to +55 °C (+32 to +131 °F); humidity 5…90% RH non-condensing
DisplayControl unit readout; display resolution 0.1% O2 standard
Sensor typeZirconium oxide MSRS (Metallic Sealed Reference Sensor) with Type K thermocouple; sensor oven +700 °C; no reference air required
NotesXZR501 is the PST order parent for the general-purpose XZR500-family combustion analyzer. Family datasheet/manual used; dedicated XZR501 order-code PDF linked on PST but returned HTML at harvest time.
Response TimeT90 20 seconds
Sample TemperatureUp to 1400 °C (2552 °F) depending on probe material
Probe Lengths0.4 / 0.6 / 0.9 m; materials 316L SS, Halar, C2000, HR160, Inconel, Kanthal, ceramic, SiC
Alarms2 user-adjustable alarms + 1 general fault alarm
WeightControl unit 7 kg; sensor head 3.5 kg; probe 1.5–4.5 kg