المعاملات الرئيسية

Measuring range
Point level (vibronic) for liquids; density >0.7 g/cm³ (optional >0.5 g/cm³)
Accuracy
Switch point ~13 mm ±1 mm from tip (vertical from above, water); hysteresis max 3 mm; non-repeatability ±1 mm
Output
3-wire DC-PNP (to 200 mA) or 2-wire AC/DC load switch (to 250 mA); MAX/MIN; IO-Link option
Supply
DC-PNP / AC-DC per electronic insert (see TI01148)
Process connection
Threads, hygienic Tri-Clamp/DIN11851, M24 adapter, flush mount options
Wetted parts
316L stainless steel; surface roughness 0.76 µm or 1.5 µm; all-metal process separation
تنزيل ورقة المواصفات PDF
المعاملالقيمة
Measuring rangePoint level (vibronic) for liquids; density >0.7 g/cm³ (optional >0.5 g/cm³)
AccuracySwitch point ~13 mm ±1 mm from tip (vertical from above, water); hysteresis max 3 mm; non-repeatability ±1 mm
Output3-wire DC-PNP (to 200 mA) or 2-wire AC/DC load switch (to 250 mA); MAX/MIN; IO-Link option
SupplyDC-PNP / AC-DC per electronic insert (see TI01148)
Process connectionThreads, hygienic Tri-Clamp/DIN11851, M24 adapter, flush mount options
Wetted parts316L stainless steel; surface roughness 0.76 µm or 1.5 µm; all-metal process separation
HousingStainless steel housing (316L); M12 / valve plug / cable options
ProtectionUp to IP69 (M12 metal cover option); IP65/66/67/68 variants per connection
Media temperature−40 to +100 °C (CIP) or −40 to +150 °C (CIP+SIP versions)
Ambient temperatureSee TI01148 ambient/process derating
DisplayLED status indication; external function test with test magnet
CommunicationIO-Link capability for parameter setting
Approvals3-A; EHEDG; WHG overfill/leakage; FDA; CSA C/US; CRN; CE
NotesSpecs from Endress+Hauser TI01148F/00/EN/05.22-00 + BA01286 + product page. Hygienic compact vibronic point level for food industry.
Process PressureVacuum … 40 bar (−1 to +40 bar / −14.5 to 580 psi)
Min Density>0.7 g/cm³ (optional >0.5 g/cm³)
Viscosity1 to 10000 mPa·s