Endress+Hauser

Endress+Hauser Proline Promag P 300 Electromagnetic Flow Meter

SKU · 45559 · Proline Promag P 300 · العلامة: Endress+Hauser
متوفر
السعر عند الطلب
بدون دفع عبر الإنترنت · أضف بنودًا إلى قائمة طلب العرض
تنزيل ورقة المواصفات PDF

طلب العرض يحمل بنود قائمة المواد فقط. أرسل لعرض هندسي.

المعاملات الرئيسية

Measuring range
Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with specified accuracy; DN sizes per TI tables
Accuracy
Standard ±0.5% o.r. ±1 mm/s; optional ±0.2% o.r. ±2 mm/s (volume flow)
Accuracy % FS
0.5
Output
4–20 mA HART; pulse/frequency/switch; optional Ethernet, PROFIBUS, PROFINET, Modbus, FOUNDATION Fieldbus per transmitter options
Supply
DC or AC transmitter supply options per TI electrical section
Process connection
Flanges EN/ASME/JIS; lap-joint and other process connections per TI
تنزيل ورقة المواصفات PDF
المعاملالقيمة
Measuring rangeTypically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with specified accuracy; DN sizes per TI tables
AccuracyStandard ±0.5% o.r. ±1 mm/s; optional ±0.2% o.r. ±2 mm/s (volume flow)
Accuracy % FS0.5
Output4–20 mA HART; pulse/frequency/switch; optional Ethernet, PROFIBUS, PROFINET, Modbus, FOUNDATION Fieldbus per transmitter options
SupplyDC or AC transmitter supply options per TI electrical section
Process connectionFlanges EN/ASME/JIS; lap-joint and other process connections per TI
Electrical connectionCable entries on compact transmitter; M12/terminals per option
Wetted partsPTFE or PFA liner; electrode materials (1.4435/316L, Alloy C22, tantalum, platinum, etc.) per order
HousingCompact transmitter housing (aluminum/SST options)
ProtectionIP66/67 (transmitter); sensor IP67/IP68 options
Media temperatureDepends on liner: PTFE/PFA process temperature tables in TI
Ambient temperatureTransmitter ambient limits per TI
Pressure typeother
DisplayLocal display/operating elements on Promag 300 transmitter
CommunicationHART; optional fieldbuses/Ethernet-APL as ordered
ApprovalsATEX/IECEx/cCSAus options; SIL capability options; PED
Hazardous areaEx approvals by order code
MountingInline electromagnetic sensor with compact Promag 300 transmitter
NotesSpecs from Endress+Hauser TI01224D (Promag P 300). Chemical/process magmeter with Heartbeat Technology.
Overpressure LimitPN 40 / Class 300 / 20K class options by size