Image unavailable
Image unavailable
Panametrics
Panametrics TransPort PT900 Ultrasonic Flow Meter
السعر عند الطلب
بدون دفع عبر الإنترنت · أضف بنودًا إلى قائمة طلب العرض
تنزيل ورقة المواصفات PDF
طلب العرض يحمل بنود قائمة المواد فقط. أرسل لعرض هندسي.
المعاملات الرئيسية
Accuracy
±1% of reading (≥2 in / 50 mm); ±2% of reading (0.5 to <2 in) with fully developed flow profile
Approvals
CE EMC IEC 61326-1:2013; WEEE Directive 2012/19/EU
Measurement Principle
Patented Correlation Transit-Time ultrasonic (clamp-on)
Fluid Types
Acoustically conductive liquids including clean liquids and many with small entrained solids/gas
Pipe Sizes
Standard 0.5 to 24 in (15 to 600 mm); optional up to 300 in (7500 mm)
Pipe Wall Thickness
Up to 3 in (76.2 mm)
| المعامل | القيمة |
|---|---|
| Accuracy | ±1% of reading (≥2 in / 50 mm); ±2% of reading (0.5 to <2 in) with fully developed flow profile |
| Approvals | CE EMC IEC 61326-1:2013; WEEE Directive 2012/19/EU |
| Measurement Principle | Patented Correlation Transit-Time ultrasonic (clamp-on) |
| Fluid Types | Acoustically conductive liquids including clean liquids and many with small entrained solids/gas |
| Pipe Sizes | Standard 0.5 to 24 in (15 to 600 mm); optional up to 300 in (7500 mm) |
| Pipe Wall Thickness | Up to 3 in (76.2 mm) |
| Velocity Range | 0.1 to 40 ft/s (0.03 to 12.19 m/s) |
| Repeatability | ±0.2% of reading |
| Enclosure | Transmitter IP65; weight 3 lb (1.4 kg); 7.9 × 4.3 × 1.5 in |
| Outputs | Analog 4–20 mA; digital pulse/frequency/alarm; Modbus RS485; Bluetooth to tablet |
| Battery Life | Lithium-ion rechargeable; 18–20 h continuous; >4 days power-saver; charger 100–240 VAC |
| Data Logging | 8 GB onboard datalogging storage |
| Operating Temperature | Discharge –20 to 55 °C (–4 to 131 °F) |
| Measurement Parameters | Velocity, volume, mass, energy, total flow |