Bently Nevada 330525 Velomitor XA
Bently Nevada 330525 Velomitor XA; 3.94 mV/mm/s; 4.5–2000 Hz; −55…+121 °C; IP65/NEMA 4X. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits harsh or outdoor casing-velocity points that need a ruggedized integrating piezo-velocity sensor without a housing — 3.94 mV/mm/s, 4.5–2000 Hz (±3 dB), operating −55 to +121 °C, IP65/NEMA 4X when properly cabled.
Key advantages
- Range / sensitivity — Velocity range 1270 mm/s (50 in/s) peak; Sensitivity 3.94 mV/mm/s (100 mV/in/s) ±5%; amplitude linearity ±2% to 152 mm/s (6 in/s) peak.
- Frequency — 4.5–2000 Hz ±3.0 dB; 6.0–1000 Hz ±0.9 dB.
- Environment — Operating −55 to +121 °C (−67 to +250 °F); IP65 / NEMA 4X when properly installed with mating extension cable; hermetically sealed case.
- Supply — DC −22 to −30 VDC; bias current 2.5–6.0 mA (per OEM DS).
- Construction — 316L stainless steel; Ø28 mm × 73.1 mm; weight 156 g typical; weatherproof connector/cable for un-housed install.
Typical applications
- Outdoor or washdown casing vibration mounts without a separate sensor housing.
- Broader-band velocity (to 2 kHz ±3 dB) where CT Velomitor bandwidth is too narrow.
- Points needing −55…+121 °C operating temperature and hermetic 316L case.
- Loops with −22…−30 VDC / 2.5–6.0 mA bias-current excitation per OEM datasheet.
Selection guide
- Sensitivity / linearity — 3.94 mV/mm/s ±5%; linearity ±2% to 152 mm/s (6 in/s) peak.
- Connector — 2-pin Mil-C-26482 hermetic, 316L shell; max cable 305 m PN 02173007.
- Shock — 5000 g peak max.
- Approvals — Multiple hazardous-area approvals (see OEM Approvals Quick Reference).
- CT vs XA — Choose 190501 CT for cooling-tower/ACHX ≥90 rpm; choose 330525 XA for harsh/outdoor broader-band duty.
Common mistakes
- Ordering CT when you need XA temperature/IP/bandwidth — XA is −55…+121 °C and 4.5–2000 Hz ±3 dB.
- Ignoring proper mating extension cable — IP65/NEMA 4X requires correct weatherproof cable install.
- Mismatching monitor excitation — supply is DC −22 to −30 VDC with 2.5–6.0 mA bias current.
- Assuming 1270 mm/s peak is the linearity window — linearity is specified ±2% to 152 mm/s peak.
When to RFQ / what to tell us
- Velocity range, frequency band, ambient/process temperature, and outdoor/washdown need.
- Cable PN/length (max 305 m PN 02173007), hazardous-area approvals, monitor excitation compatibility.
- Quantity, ship-to, mounting details.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 44338 |
| Brand | Bently Nevada |
| Model | 330525 Velomitor XA |
| Product type | velocity_sensor |
| Measuring Range | Velocity range 1270 mm/s (50 in/s) peak |
| Accuracy | Sensitivity 3.94 mV/mm/s (100 mV/in/s) ±5%; amplitude linearity ±2% to 152 mm/s (6 in/s) peak |
| Output Signal | Piezo-velocity voltage; bias −12 ±3.0 VDC over temperature (referenced to Pin A); dynamic Z <2400 Ω |
| Supply Voltage | DC −22 to −30 VDC; bias current 2.5–6.0 mA (per OEM DS) |
| Ip Rating | IP65 / NEMA 4X when properly installed with mating extension cable; hermetically sealed case |
| Ambient Temperature | Operating −55 to +121 °C (−67 to +250 °F) |
| Sensor Type | Ruggedized Velomitor XA integrating piezo-velocity sensor for harsh/outdoor mounting without housing |
| Frequency Response | 4.5–2000 Hz ±3.0 dB; 6.0–1000 Hz ±0.9 dB |
| Shock | 5000 g peak max |
| Case Material | 316L stainless steel |
| Electrical Connection | 2-pin Mil-C-26482 hermetic, 316L shell; max cable 305 m PN 02173007 |
| Mounting | Ø28 mm × 73.1 mm; weight 156 g typical; weatherproof connector/cable for un-housed install |
| Approvals | Multiple hazardous-area approvals (see OEM Approvals Quick Reference) |
| Notes | OEM Bently Nevada / Baker Hughes DS 141633 Rev. M. |
Documents
FAQ
Q: What excitation does XA need? A: DC −22 to −30 VDC with bias current 2.5–6.0 mA per OEM datasheet; bias −12 ±3.0 VDC over temperature (ref. Pin A).
Q: IP rating? A: IP65 / NEMA 4X when properly installed with mating extension cable; hermetically sealed case.
Q: What should I send for a quote? A: Band/temperature/IP need, cable length, Ex, quantity. Compatible with systems using Bently Nevada 330525 XA — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Velocity range 1270 mm/s (50 in/s) peak |
| Accuracy | Sensitivity 3.94 mV/mm/s (100 mV/in/s) ±5%; amplitude linearity ±2% to 152 mm/s (6 in/s) peak |
| Output | Piezo-velocity voltage; bias −12 ±3.0 VDC over temperature (referenced to Pin A); dynamic Z <2400 Ω |
| Supply | DC −22 to −30 VDC; bias current 2.5–6.0 mA (per OEM DS) |
| Electrical connection | 2-pin Mil-C-26482 hermetic, 316L shell; max cable 305 m PN 02173007 |
| Protection | IP65 / NEMA 4X when properly installed with mating extension cable; hermetically sealed case |
| Ambient temperature | Operating −55 to +121 °C (−67 to +250 °F) |
| Approvals | Multiple hazardous-area approvals (see OEM Approvals Quick Reference) |
| Mounting | Ø28 mm × 73.1 mm; weight 156 g typical; weatherproof connector/cable for un-housed install |
| Sensor type | Ruggedized Velomitor XA integrating piezo-velocity sensor for harsh/outdoor mounting without housing |
| Notes | OEM Bently Nevada / Baker Hughes DS 141633 Rev. M. No Instrumart. |
| Frequency Response | 4.5–2000 Hz ±3.0 dB; 6.0–1000 Hz ±0.9 dB |
| Shock | 5000 g peak max |
| Case Material | 316L stainless steel |