Key parameters
Industrial hot-film air/gas velocity and temperature transmitter for harsh duty — selectable ranges to 40 m/s (8000 ft/min), process temperature −40…120 °C, IP65 / NEMA 4 metal enclosure, duct-mount or remote probe (pressure-tight to 10 bar / 145 psi), with scalable 0–10 V / 0–20 mA outputs and calculated volumetric flow.
Key advantages
- Hot-film accuracy — multipoint factory adjustment; ranges 0…2 / 0…10 / 0…40 m/s with stated accuracies down to ±0.03 m/s on the low range.
- v + T + volume flow — temperature −40…120 °C (±0.5 °C); calculates volumetric flow from duct cross sectional area.
- Harsh-duty build — IP65 / NEMA 4 die-cast enclosure; pressure-tight remote probe option to 10 bar.
- Configurable outputs — two freely scalable analogue outputs (0–10 V or 0–20 mA / e.g. 4–20 mA).
- Setup included — configuration software and USB interface cable in OEM scope of supply.
Typical applications
- Industrial process air and non-flammable / non-corrosive gas velocity measurement.
- Duct and remote-probe installations needing high temperature or pressure rating.
- Volumetric flow monitoring where duct area is known.
- Applications needing pollution-tolerant hot-film sensing.
Selection guide
- Velocity range — 0…2 m/s, 0…10 m/s, or 0…40 m/s (order code).
- Probe type — duct mount (T2/T3) or remote probe; T26 pressure-tight 0.05…10 bar.
- Probe length / cable — select per OEM length codes.
- Outputs — two scalable 0–10 V or 0–20 mA channels.
- Supply — 24 V DC ±20% (Class III; USA/Canada Class 2).
- Environment — enclosure −40…+60 °C (−30…+60 °C with display); humidity 0…95 %RH non-condensing.
Common mistakes
- Ordering the low 0…2 m/s range for a high-speed duct — or 0…40 m/s when laminar low-speed accuracy is the goal (consider EE660).
- Skipping the T26 pressure-tight probe when the process exceeds atmospheric duct pressure.
- Using EE75 on flammable/corrosive gases — OEM limits to non-flammable, non-corrosive gases.
- Forgetting duct cross sectional area data needed for volumetric-flow calculation.
When to RFQ / what to tell us
- Velocity range code; duct vs remote vs T26 pressure-tight.
- Probe/cable length; display need; output scaling.
- Gas type, pressure, temperature, duct size for volume flow.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 43243 |
| Brand | E+E Elektronik |
| Model | EE75 |
| Product type | Air / gas velocity and temperature transmitter |
| Measuring range (velocity) | 0…2 m/s; 0…10 m/s; or 0…40 m/s (selectable) |
| Accuracy (velocity) | 0.06…2 m/s: ±0.03 m/s; 0.15…10 m/s: ±(0.1 m/s + 1% of mv); 0.2…40 m/s: ±(0.2 m/s + 1% of mv) |
| Temperature range | −40…120 °C (−40…248 °F); accuracy ±0.5 °C |
| Outputs | Two freely scalable 0–10 V and/or 0–20 mA (e.g. 4–20 mA) |
| Supply voltage | 24 V DC ±20% (Class III) |
| Protection | IP65 / NEMA 4 |
| Pressure (T26 probe) | 0.05…10 bar (0.73…145 psi) |
| Notes | Specs from epluse.com EE75 product page and datasheet_EE75.pdf. Confirm probe/range codes before order. |
Documents
FAQ
Q: Duct mount or remote probe? A: Both are offered. Choose T26 remote when pressure-tight duty to 10 bar is required.
Q: Does it measure flow volume? A: Yes — EE75 calculates volumetric flow from the configured duct cross sectional area, per E+E.
Q: What should I send for a quote? A: Range, probe type/length, outputs, gas/pressure/temp, quantity, ship-to. Compatible with systems using E+E EE75 if you need a drop-in check — we do not claim authorized-dealer status.