E+E EE660 Low Air Velocity Transmitter
E+E EE660: low air velocity from 0.15 m/s, 0…1/1.5/2 m/s, analogue or Modbus. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Low air-velocity transmitter for cleanroom and special ventilation duty — hot-film sensing accurate down to 0.15 m/s (30 ft/min), jumper-selectable ranges 0…1 / 1.5 / 2 m/s, analogue 0–10 V and 4–20 mA or RS485 Modbus RTU, IP65 / NEMA 4X enclosure, duct-mount or remote probe with optional display.
Key advantages
- Very low velocity — accurate from 0.15 m/s with stated accuracies ±(0.04…0.06 m/s + 2% of mv) by range.
- Analogue or Modbus — 0–10 V and 4–20 mA selectable, or RS485 Modbus RTU.
- Clean design — IP65 / NEMA 4X polycarbonate enclosure; pollution-tolerant sensing element.
- User configurable — jumpers or PCS10 software / configuration stick; response time typ. 4 s or 1 s.
- Mounting options — duct mount or remote probe with large backlit display option.
Typical applications
- Laminar-flow and cleanroom air-velocity control.
- Special ventilation and low-speed HVAC monitoring.
- Duct installations needing Modbus RTU networking.
- Applications where EE75’s higher ranges are unnecessary.
Selection guide
- Range — jumper selectable 0…1 / 0…1.5 / 0…2 m/s.
- Output — analogue current+voltage or Modbus RTU model.
- Probe — duct (T2) or remote with display (T3); probe lengths per OEM (e.g. 100/200/300 mm).
- Supply — 24 V AC/DC ±20% (Class III).
- Environment — humidity 5…95 %RH non-condensing; remote probe IP20, enclosure IP65/NEMA 4X.
Common mistakes
- Ordering EE660 for velocities above 2 m/s — use EE75 / EE671 instead.
- Skipping Modbus when the BMS only speaks RS485.
- Ignoring response-time selection (1 s vs 4 s) for control-loop dynamics.
- Expecting pressure-tight probes like EE75 T26 — not an EE660 feature.
When to RFQ / what to tell us
- Analogue vs Modbus; duct vs remote/display.
- Preferred measuring range and response time.
- Probe length; quantity; ship-to.
- Application (cleanroom / HVAC) notes.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 43250 |
| Brand | E+E Elektronik |
| Model | EE660 |
| Product type | Low air velocity transmitter |
| Measuring range | 0…1 / 0…1.5 / 0…2 m/s (jumper selectable) |
| Accuracy @ 20 °C, 45 %RH, 1013 hPa | ±(0.04 m/s + 2% mv) / ±(0.05 + 2%) / ±(0.06 + 2%) by range from 0.15 m/s |
| Response time | typ. 4 s or typ. 1 s (constant temperature) |
| Outputs | 0–10 V and 4–20 mA selectable; or Modbus RTU |
| Supply voltage | 24 V AC/DC ±20% |
| Protection | Enclosure IP65 / NEMA 4X; remote probe IP20 |
| Notes | Specs from epluse.com EE660 product page and datasheet_EE660.pdf. |
Documents
FAQ
Q: When choose EE660 over EE75? A: When the duty is very low velocity (cleanroom / laminar) within 0…2 m/s. EE75 covers up to 40 m/s and higher process temperatures/pressures.
Q: Can I change the range later? A: Yes — measuring range is jumper selectable; PCS10 supports configuration/adjustment.
Q: What should I send for a quote? A: Output type, probe style/length, range preference, quantity, ship-to. Compatible with systems using E+E EE660 if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Status | Specs pending OEM datasheet merge |