Image unavailable
Image unavailable
INOR IsoPAQ-21L / 22L Loop-Powered Isolators
SKU · 35536 · INOR IsoPAQ-21L / IsoPAQ-22L Loop Powered Isolators
Quote on request
No online payment · add lines to RFQ BOM
IsoPAQ-21L/22L loop-powered 0(4)–20 mA isolators; 1/2 ch; 4 kV. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Range
—
Accuracy
—
Output
—
1-channel (21L) and 2-channel (22L) loop-powered isolators for 0(4)–20 mA signals — no external supply, 4 kV isolation, Protective Separation per EN 61140, 12.5 mm DIN-rail housing.
Key advantages
- No power supply — loop-powered; lower install cost than active isolation transmitters.
- 4 kV isolation — 600 VAC/DC working voltage; Protective Separation EN 61140.
- 1- or 2-channel — IsoPAQ-22L doubles density in the same 12.5 mm width class.
- ±0.1% FS class — voltage drop <2 V; response ~2 ms @ 250 Ω / 6 ms @ 750 Ω.
Typical applications
- Breaking ground loops on 4–20 mA transmitter runs into PLC/DCS.
- Isolating field instruments from control-room I/O without adding a PSU.
- High-density DIN-rail panels needing dual-channel isolators.
Selection guide
- 21L vs 22L — 1-channel (70ISL21001) vs 2-channel (70ISL22001).
- Signals — Input/output 0(4)…20 mA; max input 30 V; max output 28 V.
- Accuracy — Transmission error ±0.1% of end value; load error ±0.03%/100 Ω.
- Environment — Operation −20…+70 °C; IP20; plug-in screw terminals ≤2.5 mm².
- Housing — 12.5 mm width; ~104 mm depth; ~100 g.
Common mistakes
- Ordering 21L when two channels in one housing (22L) would save rail space.
- Expecting signal conversion (mA↔V) — these are same-signal isolators.
- Ignoring series voltage drop (<2 V) on long loops with limited compliance.
- Accessories · Signal conditioner buying guide
When to RFQ / what to tell us
- 21L (1 ch) vs 22L (2 ch); quantity.
- Loop voltage/compliance; load resistance.
- Ship-to country; any spare-parts needs.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 35536 |
| Brand | INOR |
| Model | IsoPAQ-21L / IsoPAQ-22L |
| Product type | loop-powered isolator |
| Output signal | 0(4)…20 mA |
| Accuracy | ±0.1% FS (typical / transmission error) |
| Isolation | 4 kV, 50 Hz; working voltage 600 VAC/DC |
| Supply voltage | None (loop powered) |
| Ambient temperature | −20 to +70 °C |
| Notes | Specs from INOR IsoPAQ-21L/22L catalog sheet. |
Documents
FAQ
Q: Do I need a power supply? A: No — both 21L and 22L are loop powered from the 0(4)–20 mA signal.
Q: What should I send for a quote? A: Channel count, quantity, ship-to. Compatible with systems using INOR IsoPAQ-21L/22L if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Status | Specs pending OEM datasheet merge |