Watlow MI Band Heater
Mineral-insulated band heater to 1400 °F (760 °C), up to 480 V, SS sheath. Extruder/die/injection barrel clamp. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits extruder, die, and injection-molding barrel heating where you need a mineral-insulated band clamp heater rated to 1400 °F (760 °C) with a stainless sheath and low-mass construction for fast thermal response — not a temperature sensor or transmitter.
Key advantages
- High-temp MI band — mineral-insulated clamp heater rated to 1400 °F (760 °C).
- High watt density — up to 100 W/in² on large diameters per OEM STL-MIB sheet.
- Stainless sheath — stainless steel sheath and side-fold cover for barrel durability.
- Fast response mass — low-mass MI construction for quick thermal response on extruders and dies.
Typical applications
- Extruder and injection-molding barrel heating where clamp bands are preferred.
- Die and nozzle heating up to the published 1400 °F (760 °C) limit.
- OEM machine builds that specify MI band wattage, voltage (to 480 V), and lead style.
Selection guide
- Duty — Mineral-insulated band heater (heater product filed under Temperature category).
- Operating temperature — Up to 1400 °F (760 °C).
- Watt density — Up to 100 W/in² on large diameters (per OEM STL-MIB sheet).
- Supply — Maximum voltage to 480 V.
- Sheath / cover — Stainless steel sheath and side-fold cover.
- Mounting — Band clamp on cylinder/barrel (attached clamp bars); extruders, dies, injection molding machines.
- Electrical termination — Type B/C/E/H leads, post terminals, SLE options (12.5 A/pair leads; 30 A posts).
- Wiring — Fiberglass leads in metal braid; post terminals 10-24.
- Response — Low-mass MI construction for fast thermal response.
- Notes — Values aligned with Watlow STL-MIB-0618/0611 specification sheet. No process transmitter output; no IP or hazardous-area marks published in the OEM extract used here.
Common mistakes
- Treating this SKU as a temperature sensor — it is a resistive heater; pair it with a separate sensor/controller.
- Ordering watt density above what the barrel diameter and process can take — OEM documentation allows up to 100 W/in² on large diameters only.
- Undersizing lead current capacity (12.5 A/pair leads vs 30 A posts) for the ordered wattage and voltage.
- Specifying voltage above 480 V — maximum voltage in the sheet is 480 V.
- Expecting published IP, ambient, or hazardous-area ratings from this page — those fields are empty in our JSON; send site conditions in the RFQ.
- Temperature instruments · Temperature buying guide
When to RFQ / what to tell us
- Barrel/die OD, heater width, and clamp style.
- Required wattage / watt density and operating temperature (must fit ≤1400 °F / 760 °C).
- Available supply voltage (≤480 V) and phase.
- Termination preference (lead type B/C/E/H, post terminals, SLE) and lead length.
- Quantity and ship-to country; note if a matching temperature sensor/controller is also needed.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 21356 |
| Brand | Watlow |
| Model | MI Band |
| Product type | heater (mineral-insulated band) |
| Operating temperature | Up to 1400 °F (760 °C) |
| Watt density | Up to 100 W/in² on large diameters |
| Supply voltage | Maximum voltage to 480 V |
| Output | Resistive heating element (no process transmitter output) |
| Sheath material | Stainless steel sheath and side-fold cover |
| Housing material | Stainless steel |
| Process / mount | Band clamp on cylinder/barrel (attached clamp bars) |
| Electrical connection | Type B/C/E/H leads, post terminals, SLE (12.5 A/pair leads; 30 A posts) |
| Wiring | Fiberglass leads in metal braid; post terminals 10-24 |
| Response | Low-mass MI construction for fast thermal response |
| Notes | Specs from Watlow STL-MIB-0618/0611. Heater product — not a temperature sensor. |
Documents
FAQ
Q: Is the MI Band a temperature sensor? A: No. It is a mineral-insulated band heater. Use a separate sensor and controller for closed-loop temperature control.
Q: What temperature and voltage limits apply? A: Operating temperatures up to 1400 °F (760 °C); maximum voltage to 480 V per the specification sheet.
Q: What terminations are available? A: Type B/C/E/H leads, post terminals, and SLE options (12.5 A/pair leads; 30 A posts). State current and lead preference in the RFQ.
Q: What should I send for a quote? A: OD, width, wattage, voltage, termination, quantity, ship-to. Available for systems that use Watlow MI Band heaters — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Type | Watlow mineral insulated (MI) band / barrel heater for cylinder heating |
| Operating Temperature | Heater operating temperatures up to about 1400 °F (760 °C) |
| Watt Density | Watt densities up to about 100 W/in² (15.5 W/cm²) on large-diameter barrel bands |
| Voltage | Maximum voltage up to about 480 V |
| Construction | 430 stainless-steel sheath with high-conductivity MI insulation toward the load and low-conductivity MI backing |
| Clamping | Attached clamp bars eliminate separate clamping straps for easier installation |
| Contamination Resistance | Stainless cover and side-fold design resists plastic overflow contamination |
| Applications | Extruders, blown-film dies, injection-molding machines and other cylinder heating |
| Response | High thermal conductivity MI and low mass for rapid response and reduced thermal lag |
| Document | Watlow Mineral Insulated Band Heaters specification sheet (watlow.com) |