Fluke Calibration 4180/4181 IR Calibrator
Fluke 4180/4181 IR calibrator: −15…120 °C / 35…450 °C, 6 in target, ±0.35 °C class. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits radiometric calibration of infrared thermometers when you need a 152.4 mm (6 in) blackbody target with 4180 covering −15…120 °C or 4181 covering 35…450 °C at 0.95 nominal emissivity.
Key advantages
- Two blackbody bands — 4180 covers −15…120 °C; 4181 covers 35…450 °C at 0.95 nominal emissivity.
- 6 in target — 152.4 mm radiometrically calibrated aperture for IR thermometer calibration.
- ±0.35 °C class display — accuracy as good as ±0.35 °C (4181 at 35 °C); point-dependent stability published.
- RS-232 lab link — 115/230 Vac supply; ~10 min stabilization; magnetic-hanger-style bench footprint.
Typical applications
- Radiometric calibration of handheld and fixed IR thermometers.
- Metrology labs needing a large 6 in blackbody target.
- Shops splitting low-range (4180) and high-range (4181) IR calibrators.
Selection guide
- Measuring range — 4180: −15 to 120 °C; 4181: 35 to 450 °C (@ 23 °C ambient, 0.95 emissivity).
- Accuracy — Display accuracy as good as ±0.35 °C (4181 at 35 °C); 4180 ±0.40 °C at −15/0 °C to ±0.55 °C at 120 °C.
- Stability — 4180 ±0.05 to ±0.10 °C; 4181 ±0.05 to ±0.40 °C (point-dependent).
- Target diameter — 152.4 mm (6 inches).
- Nominal emissivity — 0.95 (radiometrically calibrated).
- Thermometer emissivity compensation — 0.9 to 1.0.
- Communication — RS-232.
- Supply — 4180: 115/230 Vac ±10%, 50/60 Hz, 630 W; 4181: 115/230 Vac, up to ~1100 W.
- Dimensions / weight — 356 × 241 × 216 mm (14 × 9.5 × 8.5 in); 4180: 9.1 kg (20 lb); 4181: 9.5 kg (21 lb).
- Stabilization / heating — Stabilization 10 minutes; 4180 ~15 min −15→120 °C; 4181 ~45 min 35→500 °C (per OEM documentation table).
Common mistakes
- Ordering 4180 when setpoints sit above 120 °C — use 4181 for 35…450 °C.
- Ordering 4181 when you need below-ambient / near-freezing points — 4180 covers −15…120 °C.
- Ignoring DUT emissivity vs the 0.95 radiometric target and 0.9…1.0 compensation window.
- Treating this as a contact dry-block well — it is an IR blackbody calibrator.
- Leaving mains (115 vs 230 Vac) blank on the RFQ.
- Calibration instruments · Blackbody calibrator buying guide
When to RFQ / what to tell us
- Model (4180 vs 4181), calibration setpoints, and DUT IR thermometer FOV vs 6 in target.
- Mains (115/230 Vac), RS-232 need, and any accredited radiometric certificate class beyond the unit report.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 24082 |
| Brand | Fluke Calibration |
| Model | 4180/4181 |
| Product type | infrared_calibrator |
| Measuring range | 4180: −15 to 120 °C; 4181: 35 to 450 °C (@ 23 °C ambient, 0.95 emissivity) |
| Accuracy | Display accuracy as good as ±0.35 °C (4181 at 35 °C); 4180 ±0.40 °C at −15/0 °C to ±0.55 °C at 120 °C |
| Stability | 4180 ±0.05 to ±0.10 °C; 4181 ±0.05 to ±0.40 °C (point-dependent) |
| Target diameter | 152.4 mm (6 inches) |
| Nominal emissivity | 0.95 (radiometrically calibrated) |
| Thermometer emissivity compensation | 0.9 to 1.0 |
| Communication | RS-232 |
| Supply voltage | 4180: 115/230 Vac ±10%, 50/60 Hz, 630 W; 4181: 115/230 Vac, up to ~1100 W |
| Dimensions | 356 × 241 × 216 mm (14 × 9.5 × 8.5 in) |
| Weight | 4180: 9.1 kg (20 lb); 4181: 9.5 kg (21 lb) |
| Stabilization time | 10 minutes |
| Heating time | 4180 ~15 min −15→120 °C; 4181 ~45 min 35→500 °C (per OEM documentation table) |
| Approvals | EN 61010-1; CAN/CSA C22.2 No. 61010.1 |
Documents
FAQ
Q: 4180 vs 4181 — which range? A: 4180 −15…120 °C; 4181 35…450 °C (@ 23 °C ambient, 0.95 emissivity). Lock the model to your setpoints.
Q: Is it a dry-block calibrator? A: No — it is a radiometric IR blackbody calibrator with a 6 in target.
Q: What should I send for a quote? A: Model, setpoints, mains, quantity. Compatible with systems using Fluke Calibration 4180/4181 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | 4180: −15 to 120 °C; 4181: 35 to 450 °C (@ 23 °C ambient, 0.95 emissivity) |
| Accuracy | Display accuracy as good as ±0.35 °C (4181 at 35 °C); 4180 ±0.40 °C at −15/0 °C to ±0.55 °C at 120 °C |
| Supply | 4180: 115/230 Vac ±10%, 50/60 Hz, 630 W; 4181: 115/230 Vac, up to ~1100 W |
| Communication | RS-232 |
| Approvals | EN 61010-1; CAN/CSA C22.2 No. 61010.1 |
| Stability | 4180 ±0.05 to ±0.10 °C; 4181 ±0.05 to ±0.40 °C (point-dependent) |
| Target Diameter | 152.4 mm (6 inches) |
| Nominal Emissivity | 0.95 (radiometrically calibrated) |
| Thermometer Emissivity Compensation | 0.9 to 1.0 |
| Dimensions | 356 × 241 × 216 mm (14 × 9.5 × 8.5 in) |
| Weight | 4180: 9.1 kg (20 lb); 4181: 9.5 kg (21 lb) |
| Stabilization Time | 10 minutes |
| Heating Time | 4180 ~15 min −15→120 °C; 4181 ~45 min 35→500 °C (per datasheet table) |