WIKA

WIKA CTI5000 Infrared Calibrator

SKU · 44304 · CTI5000 Infrared Calibrator · Brand: WIKA
Available
Quote on request
No online payment · add lines to RFQ BOM

WIKA CTI5000: IR blackbody 50…500 °C; ±0.1–0.4 K stability; ε=0.95. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Type
WIKA CTI5000 portable infrared calibrator / blackbody source (data sheet CT 41.42)
Temperature Range
50...500 C (122...932 F)
Stability
+/-0.1 K to 100 C; +/-0.2 K to 350 C; +/-0.4 K to 500 C
Resolution
0.1 K
Emissivity
Fixed 0.95
Measuring Surface
Blackbody diameter 57 mm (2.24 in); reference probe bore for 3 mm probes, 68 mm immersion
Download datasheet PDF

Fits portable IR thermometer calibration where you need a WIKA CTI5000—blackbody infrared calibrator spanning 50…500 °C with stability from ±0.1 K to ±0.4 K by temperature, fixed emissivity 0.95, and a 57 mm blackbody surface.

Key advantages

  • Range — 50…500 °C (122…932 °F)
  • Stability — ±0.1 K to 100 °C; ±0.2 K to 350 °C; ±0.4 K to 500 °C
  • Emissivity — Fixed 0.95
  • Surface — Blackbody diameter 57 mm
  • Portable — About 2.1 kg

Typical applications

  • IR thermometer cal.
  • Pyrometer checks.
  • Field blackbody reference.

Selection guide

  • Target size vs FOV
  • Power 230 V
  • Reference probe bore use

Common mistakes

  • Wrong distance/FOV.
  • Skipping stabilize time.
  • Touching hot surface.

When to RFQ / what to tell us

  1. Quantity.
  2. Ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU44304
BrandWIKA
ModelCTI5000 Infrared Calibrator
Product typeInfrared Calibrator
TypeWIKA CTI5000 portable infrared calibrator / blackbody source (data sheet CT 41.42)
Temperature range50...500 C (122...932 F)
Stability+/-0.1 K to 100 C; +/-0.2 K to 350 C; +/-0.4 K to 500 C
Resolution0.1 K
EmissivityFixed 0.95
Measuring surfaceBlackbody diameter 57 mm (2.24 in); reference probe bore for 3 mm probes, 68 mm immersion
Heating/coolingHeat about 30 min ambient to 500 C; cool about 40 min 500 to 100 C; stabilize about 15-20 min
PowerAC 230 V 50/60 Hz; about 275 VA

Documents

FAQ

Q: Range? A: 50…500 °C.

Q: Emissivity? A: Fixed 0.95.

Q: What should I send for a quote? A: Quantity, ship-to.

Links

ParameterValue
TypeWIKA CTI5000 portable infrared calibrator / blackbody source (data sheet CT 41.42)
Temperature Range50...500 C (122...932 F)
Stability+/-0.1 K to 100 C; +/-0.2 K to 350 C; +/-0.4 K to 500 C
Resolution0.1 K
EmissivityFixed 0.95
Measuring SurfaceBlackbody diameter 57 mm (2.24 in); reference probe bore for 3 mm probes, 68 mm immersion
Heating CoolingHeat about 30 min ambient to 500 C; cool about 40 min 500 to 100 C; stabilize about 15-20 min
PowerAC 230 V 50/60 Hz; about 275 VA
Dimensions WeightAbout 190 x 248 x 113 mm; 2.1 kg (4.6 lb)
DocumentWIKA data sheet CT 41.42 Infrared calibrator model CTI5000 (wika.com)