Duct CO2 0–2000 ppm; NDIR; 0–10 V; ABC Logic. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Duct-mount CO2 transmitter / Ventostat probe (T8041 / T8042)
Measurement Range
0–2000 ppm CO2
Sensing
Absorption infrared (NDIR) CO2 sensing
Output T8041
0–10 V analog (T8041); T8041-5V option 0–5 V
Calibration
ABC Logic automatic background calibration
Probe
Approx. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box
Fits HVAC return-air CO₂ demand-controlled ventilation where you need a Telaire Ventostat T8041 duct probe with 0–2000 ppm NDIR sensing and 0–10 V analog output.
Key advantages
- Range — 0–2000 ppm CO₂
- Sensing — Absorption infrared (NDIR)
- Output — 0–10 V (T8041); T8041-5V option 0–5 V
- Calibration — ABC Logic automatic background calibration
- Install — ~4.09 in probe; 1½ in duct hole; 3.05×3.05 in junction box
Typical applications
- Return-air duct CO₂ for DCV.
- HVAC energy optimization with Ventostat probes.
- Sites standardizing on T8041/T8042 family.
Selection guide
- Output — 0–10 V vs 0–5 V option
- Sibling — T8042 if different I/O needed
- Duct — Hole size and probe length fit
- ABC Logic — Suitable occupied-space background yes/no
Common mistakes
- Mounting in supply instead of return when DCV expects return air.
- Disabling ABC Logic without a calibration plan.
- Wrong voltage option vs controller input.
When to RFQ / what to tell us
- 0–10 V vs 0–5 V; duct size.
- Controller input type; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 21738 |
| Brand | Telaire (Amphenol Advanced Sensors) |
| Model | Ventostat T8041 |
| Product type | CO2 Duct Transmitter |
| Type | Duct-mount CO2 transmitter / Ventostat probe (T8041 / T8042) |
| Range | 0–2000 ppm CO2 |
| Sensing | Absorption infrared (NDIR) CO2 sensing |
| Output | 0–10 V analog (T8041); T8041-5V option 0–5 V |
| Calibration | ABC Logic automatic background calibration |
| Probe | Approx. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box |
| Installation | 1½ in duct hole; two ⅛ in mounting screws |
| Applications | HVAC return-air duct CO2 demand-controlled ventilation |
| Family | Telaire Ventostat T8041/T8042 duct probe transmitters (Amphenol Advanced Sensors) |
Documents
FAQ
Q: Range? A: 0–2000 ppm CO₂.
Q: Output? A: 0–10 V standard; 0–5 V option (T8041-5V).
Q: What should I send for a quote? A: Output option, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Duct-mount CO2 transmitter / Ventostat probe (T8041 / T8042) |
| Measurement Range | 0–2000 ppm CO2 |
| Sensing | Absorption infrared (NDIR) CO2 sensing |
| Output T8041 | 0–10 V analog (T8041); T8041-5V option 0–5 V |
| Calibration | ABC Logic automatic background calibration |
| Probe | Approx. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box |
| Installation | 1½ in duct hole; two ⅛ in mounting screws |
| Applications | HVAC return-air duct CO2 demand-controlled ventilation |
| Family | Telaire Ventostat T8041/T8042 duct probe transmitters (Amphenol Advanced Sensors) |
| Document | Amphenol AAS-920-376G Telaire Ventostat T8041/T8042 datasheet |