Telaire

Telaire Ventostat T8041 CO2 Duct Probe Transmitter

SKU · 21738 · Ventostat T8041 · Brand: Telaire
Available
Quote on request
No online payment · add lines to RFQ BOM

Duct CO2 0–2000 ppm; NDIR; 0–10 V; ABC Logic. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Type
Duct-mount CO2 transmitter / Ventostat probe (T8041 / T8042)
Measurement Range
0–2000 ppm CO2
Sensing
Absorption infrared (NDIR) CO2 sensing
Output T8041
0–10 V analog (T8041); T8041-5V option 0–5 V
Calibration
ABC Logic automatic background calibration
Probe
Approx. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box
Download datasheet PDF

Fits HVAC return-air CO₂ demand-controlled ventilation where you need a Telaire Ventostat T8041 duct probe with 0–2000 ppm NDIR sensing and 0–10 V analog output.

Key advantages

  • Range — 0–2000 ppm CO₂
  • Sensing — Absorption infrared (NDIR)
  • Output — 0–10 V (T8041); T8041-5V option 0–5 V
  • Calibration — ABC Logic automatic background calibration
  • Install — ~4.09 in probe; 1½ in duct hole; 3.05×3.05 in junction box

Typical applications

  • Return-air duct CO₂ for DCV.
  • HVAC energy optimization with Ventostat probes.
  • Sites standardizing on T8041/T8042 family.

Selection guide

  • Output — 0–10 V vs 0–5 V option
  • Sibling — T8042 if different I/O needed
  • Duct — Hole size and probe length fit
  • ABC Logic — Suitable occupied-space background yes/no

Common mistakes

  • Mounting in supply instead of return when DCV expects return air.
  • Disabling ABC Logic without a calibration plan.
  • Wrong voltage option vs controller input.

When to RFQ / what to tell us

  1. 0–10 V vs 0–5 V; duct size.
  2. Controller input type; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU21738
BrandTelaire (Amphenol Advanced Sensors)
ModelVentostat T8041
Product typeCO2 Duct Transmitter
TypeDuct-mount CO2 transmitter / Ventostat probe (T8041 / T8042)
Range0–2000 ppm CO2
SensingAbsorption infrared (NDIR) CO2 sensing
Output0–10 V analog (T8041); T8041-5V option 0–5 V
CalibrationABC Logic automatic background calibration
ProbeApprox. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box
Installation1½ in duct hole; two ⅛ in mounting screws
ApplicationsHVAC return-air duct CO2 demand-controlled ventilation
FamilyTelaire Ventostat T8041/T8042 duct probe transmitters (Amphenol Advanced Sensors)

Documents

FAQ

Q: Range? A: 0–2000 ppm CO₂.

Q: Output? A: 0–10 V standard; 0–5 V option (T8041-5V).

Q: What should I send for a quote? A: Output option, quantity, ship-to.

Links

ParameterValue
TypeDuct-mount CO2 transmitter / Ventostat probe (T8041 / T8042)
Measurement Range0–2000 ppm CO2
SensingAbsorption infrared (NDIR) CO2 sensing
Output T80410–10 V analog (T8041); T8041-5V option 0–5 V
CalibrationABC Logic automatic background calibration
ProbeApprox. 4.09 in probe length, 1.24 in diameter; 3.05×3.05 in junction box
Installation1½ in duct hole; two ⅛ in mounting screws
ApplicationsHVAC return-air duct CO2 demand-controlled ventilation
FamilyTelaire Ventostat T8041/T8042 duct probe transmitters (Amphenol Advanced Sensors)
DocumentAmphenol AAS-920-376G Telaire Ventostat T8041/T8042 datasheet