Image unavailable
Image unavailable
Telaire
Telaire T5100 CO2 Transmitter
Quote on request
No online payment · add lines to RFQ BOM
Telaire T5100: wall CO2; 0–2000 ppm; ±30 ppm or 3%; 0–5/10 V or 4–20 mA. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Wall-mount CO2 transmitter for building controls / DCV (Telaire T5100 Series)
Sensing
NDIR absorption; gold-plated optics; patented ABC Logic self-calibration
Co2 Range
0 to 2000 ppm (0 ppm = 0 V / 4 mA)
Co2 Accuracy
+/-30 ppm or 3% of reading, whichever higher
Outputs
Field-selectable 0-5 V / 0-10 V or 4-20 mA (not simultaneous)
Power
18-30 VAC RMS 50/60 Hz or 18-42 VDC; typ. 0.7 W @ 24 VAC
Fits building CO2 demand-control ventilation where you need a Telaire T5100. Wall-mount NDIR CO2 transmitter with gold-plated optics and ABC Logic self-calibration, 0 to 2000 ppm range, accuracy ±30 ppm or 3% of reading (whichever higher), field-selectable 0–5 V / 0–10 V or 4–20 mA outputs, 18–30 VAC or 18–42 VDC power, and 0 to 50 °C / 0–95% RH non-condensing operation.
Key advantages
- Range — 0–2000 ppm
- Accuracy — ±30 ppm or 3% reading
- Sensing — NDIR + ABC Logic
- Outputs — 0–5/10 V or 4–20 mA
- Power — 18–30 VAC or 18–42 VDC
Typical applications
- DCV building controls.
- Wall CO2 monitoring.
- HVAC IAQ transmitters.
Selection guide
- Output selection
- Power type
- Mount location
Common mistakes
- Simultaneous V and mA (not supported).
- Condensing humidity.
- Ignoring warm-up time.
When to RFQ / what to tell us
- Output/power options.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 39156 |
| Brand | Telaire |
| Model | T5100 CO2 Transmitter |
| Product type | CO2 Transmitter |
| Type | Wall-mount CO2 transmitter for building controls / DCV (Telaire T5100 Series) |
| Sensing | NDIR absorption; gold-plated optics; patented ABC Logic self-calibration |
| CO2 range | 0 to 2000 ppm (0 ppm = 0 V / 4 mA) |
| CO2 accuracy | +/-30 ppm or 3% of reading, whichever higher |
| Outputs | Field-selectable 0-5 V / 0-10 V or 4-20 mA (not simultaneous) |
| Power | 18-30 VAC RMS 50/60 Hz or 18-42 VDC; typ. 0.7 W @ 24 VAC |
| Update | Signal update every 5 seconds; warm-up <2 min operational / 10 min full accuracy |
| Operating conditions | 0 to 50 C (32 to 122 F); 0-95% RH non-condensing |
Documents
FAQ
Q: Range? A: 0 to 2000 ppm.
Q: Accuracy? A: ±30 ppm or 3% of reading.
Q: What should I send for a quote? A: Output/power options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Wall-mount CO2 transmitter for building controls / DCV (Telaire T5100 Series) |
| Sensing | NDIR absorption; gold-plated optics; patented ABC Logic self-calibration |
| Co2 Range | 0 to 2000 ppm (0 ppm = 0 V / 4 mA) |
| Co2 Accuracy | +/-30 ppm or 3% of reading, whichever higher |
| Outputs | Field-selectable 0-5 V / 0-10 V or 4-20 mA (not simultaneous) |
| Power | 18-30 VAC RMS 50/60 Hz or 18-42 VDC; typ. 0.7 W @ 24 VAC |
| Update | Signal update every 5 seconds; warm-up <2 min operational / 10 min full accuracy |
| Operating Conditions | 0 to 50 C (32 to 122 F); 0-95% RH non-condensing |
| Stability | <2% FS over 15-year sensor life; lifetime calibration warranty with ABC Logic |
| Document | Amphenol Advanced Sensors AAS-920-586F Telaire T5100 datasheet (02/2022) |