Telaire

Telaire T8000-R Wall Mount CO2 & Temperature Transmitter

SKU · 40628 · T8000-R Series · Brand: Telaire
Available
Quote on request
No online payment · add lines to RFQ BOM

T8000-R: 0–2000/5000 ppm CO2; 0–5/10 V or 4–20 mA; relay. RFQ model.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Type
Wall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series)
Co2 Range
0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models)
Co2 Accuracy
Single-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10%
Outputs
0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay
Power
18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC
Temperature
Active 0–50 °C; accuracy ±1 °C from 15–30 °C
Download datasheet PDF

Fits wall-mount indoor air monitoring where you need a Telaire T8000-R—NDIR CO2 and temperature transmitter with 0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P) ranges, selectable 0–5/0–10 V or 4–20 mA outputs, and a NO/NC relay.

Key advantages

  • CO2 — 0–2000 ppm or 0–5000 ppm models
  • Accuracy — Single-ch ±30 ppm or 3% rdg; dual-ch ±75 ppm or 10%
  • Outputs — 0–5 V / 0–10 V or 4–20 mA; NO/NC relay
  • Power — 18–30 VAC RMS or 18–42 VDC; ~0.7 W at 24 VAC typ
  • Form — Wall-mount CO2 + temperature

Typical applications

  • Building IAQ / DCV.
  • Classroom / office CO2 control.
  • HVAC demand ventilation.

Selection guide

  • 2000 vs 5000 ppm
  • Single vs dual channel
  • Voltage vs mA

Common mistakes

  • Mounting in dead air pockets.
  • Wrong supply VAC/VDC.
  • Relay logic inverted.

When to RFQ / what to tell us

  1. Model/range, output.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU40628
BrandTelaire
ModelT8000-R Series
Product typeCO2 Transmitter
TypeWall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series)
CO2 range0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models)
CO2 accuracySingle-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10%
Outputs0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay
Power18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC

Documents

FAQ

Q: Ranges? A: 0–2000 or 0–5000 ppm by model.

Q: Relay? A: Yes — NO/NC relay.

Q: What should I send for a quote? A: Model/output, quantity, ship-to.

Links

ParameterValue
TypeWall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series)
Co2 Range0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models)
Co2 AccuracySingle-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10%
Outputs0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay
Power18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC
TemperatureActive 0–50 °C; accuracy ±1 °C from 15–30 °C
CalibrationABC Logic self-calibration; lifetime CO2 calibration warranty when ABC on
EnclosureModern wall enclosure; conformal coating on 0–5000 ppm models; UL94 5VA
DocumentAmphenol Advanced Sensors AAS-920-636B Telaire T8000-R datasheet