Image unavailable
Image unavailable
Telaire
Telaire T8000-R Wall Mount CO2 & Temperature Transmitter
Quote on request
No online payment · add lines to RFQ BOM
T8000-R: 0–2000/5000 ppm CO2; 0–5/10 V or 4–20 mA; relay. RFQ model.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Wall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series)
Co2 Range
0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models)
Co2 Accuracy
Single-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10%
Outputs
0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay
Power
18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC
Temperature
Active 0–50 °C; accuracy ±1 °C from 15–30 °C
Fits wall-mount indoor air monitoring where you need a Telaire T8000-R—NDIR CO2 and temperature transmitter with 0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P) ranges, selectable 0–5/0–10 V or 4–20 mA outputs, and a NO/NC relay.
Key advantages
- CO2 — 0–2000 ppm or 0–5000 ppm models
- Accuracy — Single-ch ±30 ppm or 3% rdg; dual-ch ±75 ppm or 10%
- Outputs — 0–5 V / 0–10 V or 4–20 mA; NO/NC relay
- Power — 18–30 VAC RMS or 18–42 VDC; ~0.7 W at 24 VAC typ
- Form — Wall-mount CO2 + temperature
Typical applications
- Building IAQ / DCV.
- Classroom / office CO2 control.
- HVAC demand ventilation.
Selection guide
- 2000 vs 5000 ppm
- Single vs dual channel
- Voltage vs mA
Common mistakes
- Mounting in dead air pockets.
- Wrong supply VAC/VDC.
- Relay logic inverted.
When to RFQ / what to tell us
- Model/range, output.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 40628 |
| Brand | Telaire |
| Model | T8000-R Series |
| Product type | CO2 Transmitter |
| Type | Wall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series) |
| CO2 range | 0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models) |
| CO2 accuracy | Single-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10% |
| Outputs | 0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay |
| Power | 18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC |
Documents
FAQ
Q: Ranges? A: 0–2000 or 0–5000 ppm by model.
Q: Relay? A: Yes — NO/NC relay.
Q: What should I send for a quote? A: Model/output, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Wall-mount NDIR CO2 and temperature transmitter with relay (T8000-R Series) |
| Co2 Range | 0–2000 ppm (T8100-R) or 0–5000 ppm (T8200-R / 5P models) |
| Co2 Accuracy | Single-channel ±30 ppm or 3% of reading (whichever greater); dual-channel ±75 ppm or 10% |
| Outputs | 0–5 V / 0–10 V selectable or 4–20 mA; NO/NC relay |
| Power | 18–30 VAC RMS or 18–42 VDC; typical 0.7 W at 24 VAC |
| Temperature | Active 0–50 °C; accuracy ±1 °C from 15–30 °C |
| Calibration | ABC Logic self-calibration; lifetime CO2 calibration warranty when ABC on |
| Enclosure | Modern wall enclosure; conformal coating on 0–5000 ppm models; UL94 5VA |
| Document | Amphenol Advanced Sensors AAS-920-636B Telaire T8000-R datasheet |