Testo

Extech CT70 GFCI and AC Circuit Analyzer

SKU · 35928 · 0613 1212 · Brand: Testo
Available
Quote on request
No online payment · add lines to RFQ BOM

CT70: 12/15/20 A load; V-drop; GFCI/EPD; CAT II 300 V. RFQ qty.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
−50 to +150 °C (−58 to +302 °F)
Accuracy
±0.2 °C (−25 to +74.9 °C); ±0.4 °C remaining range; ±0.5% of m.v. (+100 to +150 °C)
Sensor type
NTC (thermistor) waterproof immersion/penetration probe
Part Number
0613 1212
Response Time
t99 ≈ 10 s
Cable
Fixed cable 1.2 m (3.937 ft)
Download datasheet PDF

Fits outlet and branch-circuit load checks where you need an Extech CT70—selectable 12/15/20 A loads, voltage drop and impedance, plus GFCI/EPD trip tests and wiring fault indication on a color pass/fail display.

Key advantages

  • Loads — Selectable 12 / 15 / 20 A
  • Line — 90–240 V AC; 45–65 Hz; peak to 350 V
  • Drop — Voltage drop 0.1–99.9%; line impedance
  • GFCI — Trip time/current; EPD test path
  • Safety — CAT II 300 V class; North American 3-prong cord

Typical applications

  • Outlet load-handling checks.
  • GFCI verification.
  • Wiring polarity / impedance surveys.

Selection guide

  • Spare CT70-AC cord
  • Target load ampacity
  • GFCI vs EPD path

Common mistakes

  • Using on UPS / dimmer / square-wave outputs.
  • Repeating load tests without cool-down.
  • Expecting non-NA plug without adapter plan.

When to RFQ / what to tell us

  1. Quantity, spare cord.
  2. Ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU35928
BrandExtech
ModelCT70
Product typeAC Circuit Analyzer
TypeGFCI / AC circuit load analyzer (Extech CT70)
AC voltage90.0–240.0 V (line); peak to 350.0 V
Frequency45.0–65.0 Hz
Voltage drop0.1–99.9%
LoadsSelectable 12 / 15 / 20 A load tests
Outlet testsHot/neutral/ground impedance; N–G voltage; open/reversed wiring; GFCI trip time/current; EPD
SafetyCAT II 300 V class

Documents

FAQ

Q: Load currents? A: Selectable 12, 15, and 20 A.

Q: GFCI test? A: Yes — GFCI trip time/current; EPD path available.

Q: What should I send for a quote? A: Quantity, ship-to.

Links

ParameterValue
Measuring range−50 to +150 °C (−58 to +302 °F)
Accuracy±0.2 °C (−25 to +74.9 °C); ±0.4 °C remaining range; ±0.5% of m.v. (+100 to +150 °C)
Sensor typeNTC (thermistor) waterproof immersion/penetration probe
Part Number0613 1212
Response Timet99 ≈ 10 s
CableFixed cable 1.2 m (3.937 ft)
Shaft DimensionsLength 115 mm; Ø5 mm shaft; tip 50 mm × Ø4 mm
ProtectionIP54; waterproof probe construction
Weight145 g (5.12 oz)
Housing ColorsPlastic housing; grey / black / silver
Typical Hoststesto 112 / testo 110 and other NTC-compatible instruments
Documenttesto.com 0613 1212 product page + testo 112 data sheet probe table