CAS

CAS CAST-X 1000 Circulation Heater

SKU · 43193 · CAST-X 1000 · Brand: CAS
Available
Quote on request
No online payment · add lines to RFQ BOM

CAS CAST-X 1000: 700 W–3 kW; 316L tube; to 2100 psi; NEMA 1/4. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Power
700 W to 3 kW total
Voltage
120–480 V; max line current 15 A
Tubing
0.313 in OD (5/16 in / 7.9 mm), 0.020 in wall; overall process tube length 137 in (3480 mm)
Tube Material
316L stainless steel standard; Inconel / passivated / electro-polished options
Max Pressure
2100 psi (144 bar)
Enclosures
NEMA 1 (general-purpose); NEMA 4 (moisture-resistant); no-enclosure option
Download datasheet PDF

Fits compact cast-aluminum circulation heating where you need a CAS CAST-X 1000. Heater from 700 W to 3 kW at 120–480 V (max line current 15 A), 0.313 in OD 316L process tube (Inconel/passivated/EP options), max pressure 2100 psi, NEMA 1 / NEMA 4 / no-enclosure options, max working temperature up to 662 °F (350 °C) with no enclosure, and K/J thermocouples with snap-action high-limit options.

Key advantages

  • Power — 700 W to 3 kW
  • Pressure — To 2100 psi
  • Tube — 316L SS helical path
  • Enclosures — NEMA 1 / 4 / none
  • Design — Cast Al; self-draining

Typical applications

  • Solvent / gas heating.
  • Compact circulation heaters.
  • Coating and resin heat.

Selection guide

  • kW / voltage
  • Enclosure
  • Tube material options

Common mistakes

  • Exceeding enclosure temp class.
  • Wrong voltage/current.
  • Ignoring high-limit sensors.

When to RFQ / what to tell us

  1. kW/enclosure/options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU43193
BrandCast Aluminum Solutions (CAS)
ModelCAST-X 1000
Product typeCirculation Heater
Power700 W to 3 kW total
Voltage120–480 V; max line current 15 A
Tubing0.313 in OD (5/16 in / 7.9 mm), 0.020 in wall; overall process tube length 137 in (3480 mm)
Tube material316L stainless steel standard; Inconel / passivated / electro-polished options
Max pressure2100 psi (144 bar)
EnclosuresNEMA 1 (general-purpose); NEMA 4 (moisture-resistant); no-enclosure option
Max working temperatureNo enclosure 662°F (350°C); NEMA 1 608°F (320°C); NEMA 4 482°F (250°C); with thermostat 250°F (121°C)
SensorsK or J thermocouples; snap-action high-limit; process/high-limit TCs; enclosure thermostat options

Documents

FAQ

Q: Power? A: 700 W to 3 kW.

Q: Max pressure? A: 2100 psi.

Q: What should I send for a quote? A: kW/enclosure/options, quantity, ship-to.

Links

ParameterValue
Power700 W to 3 kW total
Voltage120–480 V; max line current 15 A
Tubing0.313 in OD (5/16 in / 7.9 mm), 0.020 in wall; overall process tube length 137 in (3480 mm)
Tube Material316L stainless steel standard; Inconel / passivated / electro-polished options
Max Pressure2100 psi (144 bar)
EnclosuresNEMA 1 (general-purpose); NEMA 4 (moisture-resistant); no-enclosure option
Max Working TemperatureNo enclosure 662°F (350°C); NEMA 1 608°F (320°C); NEMA 4 482°F (250°C); with thermostat 250°F (121°C)
SensorsK or J thermocouples; snap-action high-limit; process/high-limit TCs; enclosure thermostat options
DesignCast aluminum body; helical SS flow tube separate from heating elements; self-draining
ApplicationsSolvent heating, H2O2 vaporization, air/CO2/N2, coating/resin, steam, engine pre-heat