Image unavailable
Image unavailable
AEMC
AEMC CM605 100A AC/DC Low Current Clamp Meter
Quote on request
No online payment · add lines to RFQ BOM
AEMC CM605: 10/100 A; 1 mA res; 600 V; 10 mV/A out. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
Current 10 A / 100 A AC/DC (1 mA resolution on 10 A); Voltage 600 V AC/DC; Resistance to 10 kΩ
Accuracy
AC current 10 A: 2.0% R ±10 cts; Voltage AC 1.5% R ±5 cts (typical per CM605 datasheet)
Output
Analog output 10 mV/A AC & DC via front banana jacks
Supply
2× 1.5 V AAA
Ambient temperature
Operating +32 to 104 °F (0 to +40 °C)
Display
10,000-count LCD; HOLD / PEAK / relative
Fits low-current AC/DC clamp work where you need an AEMC CM605—10 A and 100 A ranges with 1 mA resolution on the 10 A range, about 2.0%/2.5% accuracy class, 600 V AC/DC, resistance/continuity, and a 10 mV/A analog output.
Key advantages
- Current — 10 A and 100 A ranges; 1 mA resolution on 10 A
- Accuracy — AC ~2.0% ±10 counts; DC ~2.5% ±10 counts class
- Other — 600 V AC/DC; Ω; continuity; 10 mV/A analog out
- Safety — 600 V CAT II / 300 V CAT III
- Power — 2× AAA
Typical applications
- Low-current process loops.
- 4–20 mA clamp checks (range permitting).
- Small-motor current.
Selection guide
- vs higher-amp clamps
- Analog out use
- Jaw opening
Common mistakes
- Expecting high-amp welding currents.
- DC polarity awareness.
- Ignoring CAT class.
When to RFQ / what to tell us
- Quantity.
- Ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 42406 |
| Brand | AEMC |
| Model | CM605 |
| Product type | Clamp Meter |
| Type | Low-current AC/DC clamp-on meter (CM605) |
| Current | 10 A and 100 A ranges; 1 mA resolution on 10 A |
| Accuracy | AC ~2.0% ±10 counts; DC ~2.5% ±10 counts class |
| Other | 600 V AC/DC; resistance; continuity; 10 mV/A analog out |
| Safety | 600 V CAT II / 300 V CAT III; 2× AAA |
Documents
FAQ
Q: Ranges? A: 10 A and 100 A.
Q: Resolution? A: 1 mA on the 10 A range.
Q: What should I send for a quote? A: Quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | Current 10 A / 100 A AC/DC (1 mA resolution on 10 A); Voltage 600 V AC/DC; Resistance to 10 kΩ |
| Accuracy | AC current 10 A: 2.0% R ±10 cts; Voltage AC 1.5% R ±5 cts (typical per CM605 datasheet) |
| Output | Analog output 10 mV/A AC & DC via front banana jacks |
| Supply | 2× 1.5 V AAA |
| Ambient temperature | Operating +32 to 104 °F (0 to +40 °C) |
| Display | 10,000-count LCD; HOLD / PEAK / relative |
| Approvals | CE; IEC/EN 61010 600 V CAT II / 300 V CAT III |
| Mounting | Handheld; jaw opening Ø 0.60 in (15 mm); max cable Ø 0.45 in (12 mm) |
| Sensor type | Low-current AC/DC clamp-on ammeter/voltmeter |
| Notes | Cat. #7000.02 CM605 100 A AC/DC low-current clamp. Specs from aemc.com datasheet 7000-02 + CM605_EN manual. |
| Jaw Opening | 0.60 in (15 mm) |
| Continuity | Buzzer <100 Ω ±25 Ω |