Fuji Electric

Fuji Electric ZKME In-Situ Zirconia O2 Analyzer

SKU · 345-0001 · ZKME · Brand: Fuji Electric
Available
Quote on request
No online payment · add lines to RFQ BOM

ZKME/ZFKE: 0–2…50 vol% O2; −10…+600 °C gas; 4–20 mA; hazloc. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0 to 2 … 0 to 50 vol% O2; 2 ranges in 1 vol% steps
Measuring Object
Oxygen in noncombustible gas (zirconia in-situ)
Analog Output
4–20 mA DC (≤500 Ω) or 0–1 V DC
Detector Gas Temp
−10 to +600 °C (ZFKE detector)
Gas Pressure
−3 to +3 kPa
Power
100–120 Vac or 200–240 Vac, 50/60 Hz; startup ~240 VA, run ~70 VA
Download datasheet PDF

Fits hazardous-location combustion O₂ where you need a Fuji Electric ZKME converter with ZFKE in-situ zirconia detector—ranges 0–2…0–50 vol% O₂ and detector gas temperature −10…+600 °C.

Key advantages

  • Range — 0 to 2 … 0 to 50 vol% O₂ (2 ranges in 1 vol% steps)
  • Output — 4–20 mA DC (≤500 Ω) or 0–1 V DC
  • Detector gas T — −10 to +600 °C (ZFKE)
  • Pressure — −3 to +3 kPa
  • Protection — Converter IP65; detector IP66 class (excl. probe tip per OEM)

Typical applications

  • Boiler / furnace O₂ trim.
  • Hazardous-area combustion monitoring.
  • In-situ flue gas oxygen.

Selection guide

  • Converter + detector pairing
  • Hazloc approvals
  • Cable / probe length
  • AC supply 100–120 vs 200–240

Common mistakes

  • Using on combustible process gas outside OEM limits.
  • Ignoring ±3 kPa pressure window.
  • Wrong supply voltage.

When to RFQ / what to tell us

  1. ZKME/ZFKE config, approvals.
  2. Probe length, quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU345-0001
BrandFuji Electric
ModelZKME
Product typeZirconia Oxygen Analyzer
Measuring objectOxygen in noncombustible gas (zirconia in-situ)
Measuring range0 to 2 … 0 to 50 vol% O2; 2 ranges in 1 vol% steps
Analog output4–20 mA DC (≤500 Ω) or 0–1 V DC
Detector gas temp−10 to +600 °C (ZFKE detector)
Gas pressure−3 to +3 kPa
Power100–120 Vac or 200–240 Vac, 50/60 Hz; startup ~240 VA, run ~70 VA
Converter IPIP65 equivalent (ZKME converter)
Detector IPIP66 equivalent excluding filter (ZFKE)

Documents

FAQ

Q: O₂ range? A: 0–2 to 0–50 vol% O₂ configurable.

Q: Detector temperature? A: −10 to +600 °C gas at ZFKE.

Q: What should I send for a quote? A: Config/approvals, quantity, ship-to.

Links

ParameterValue
Measuring range0 to 2 … 0 to 50 vol% O2; 2 ranges in 1 vol% steps
Measuring ObjectOxygen in noncombustible gas (zirconia in-situ)
Analog Output4–20 mA DC (≤500 Ω) or 0–1 V DC
Detector Gas Temp−10 to +600 °C (ZFKE detector)
Gas Pressure−3 to +3 kPa
Power100–120 Vac or 200–240 Vac, 50/60 Hz; startup ~240 VA, run ~70 VA
Converter IpIP65 equivalent (ZKME converter)
Detector IpIP66 equivalent excluding filter (ZFKE)
Contact Outputs6 points SPST-NO, 250 Vac 3 A or 30 Vdc 3 A
Indication4-digit digital O2 concentration
Hazardous LocationIn-situ zirconia analyzer for hazardous location (ZKME/ZFKE family)
FilterSS316, 60 µm filtering accuracy