GF Signet

GF Signet 2850 Conductivity/Resistivity Sensor

SKU · 20204 · 2850 · Brand: GF Signet
Available
Quote on request
No online payment · add lines to RFQ BOM

0.055–400,000 µS/cm; S3L or 4–20 mA; NEMA 4X. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Conductivity ±2% of reading; temperature ±0.2 °C
Type
Type 2850 conductivity/resistivity sensor electronics (universal, j-box, integral)
Range Conductivity
0.055…400,000 µS/cm
Range Resistivity
18.2 MΩ…10 kΩ
Outputs
Digital S3L or two-wire 4–20 mA (field-selectable ranges per cell constant)
Cell Constants
Integral systems with 0.01 / 0.1 / 1.0 / 10.0 / 20.0 cm⁻¹ electrodes
Download datasheet PDF

Fits conductivity and resistivity loops where you need a GF Signet Type 2850 with 0.055–400,000 µS/cm / 18.2 MΩ–10 kΩ coverage, S3L or 4–20 mA outputs, and cell constants from 0.01 to 20.0 cm⁻¹.

Key advantages

  • Ranges — Conductivity 0.055…400,000 µS/cm; resistivity 18.2 MΩ…10 kΩ
  • Accuracy — Conductivity ±2% of reading; temperature ±0.2 °C
  • Outputs — Digital S3L or two-wire 4–20 mA (field-selectable)
  • Cells — Integral 0.01 / 0.1 / 1.0 / 10.0 / 20.0 cm⁻¹ electrodes
  • Enclosure — NEMA 4X / IP65 PBT; EasyCal; pairs with 9900/9950

Typical applications

  • RO, DI, and demineralizer loops.
  • Scrubbers, cooling towers, aquatic life support.
  • Dual-channel 2850-63 with GF 9950.

Selection guide

  • Cell constant — Match process conductivity/resistivity
  • Output — S3L vs 4–20 mA
  • Form — Universal / j-box / integral
  • Transmitter — 9900 / 9950 pairing

Common mistakes

  • Wrong cell constant for ultrapure vs high-conductivity water.
  • Expecting dual channel on a single-channel code.
  • Ignoring −10…+85 °C electronics limit.

When to RFQ / what to tell us

  1. Conductivity/resistivity range; cell constant.
  2. Output form; transmitter; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU20204
BrandGeorg Fischer / GF Signet
ModelSignet 2850 Conductivity / Resistivity Sensor
Product typeConductivity / Resistivity Sensor
TypeType 2850 conductivity/resistivity sensor electronics (universal, j-box, integral)
Conductivity range0.055…400,000 µS/cm
Resistivity range18.2 MΩ…10 kΩ
AccuracyConductivity ±2% of reading; temperature ±0.2 °C
OutputsDigital S3L or two-wire 4–20 mA (field-selectable ranges per cell constant)
Cell constantsIntegral systems with 0.01 / 0.1 / 1.0 / 10.0 / 20.0 cm⁻¹ electrodes
EnclosureNEMA 4X / IP65 PBT electronics enclosure
Temp compensationPT-1000 RTD; EasyCal automatic test-solution recognition
TransmittersPairs with GF 9900 / 9950; dual-channel 2850-63 for 9950 I/O optimization
Operating temperature−10…+85 °C (electronics)
ApplicationRO, DI, demineralizer, scrubber, cooling tower, aquatic life support

Documents

FAQ

Q: Conductivity range? A: 0.055…400,000 µS/cm.

Q: Outputs? A: Digital S3L or two-wire 4–20 mA.

Q: What should I send for a quote? A: Range/cell/output, quantity, ship-to.

Links

ParameterValue
AccuracyConductivity ±2% of reading; temperature ±0.2 °C
TypeType 2850 conductivity/resistivity sensor electronics (universal, j-box, integral)
Range Conductivity0.055…400,000 µS/cm
Range Resistivity18.2 MΩ…10 kΩ
OutputsDigital S3L or two-wire 4–20 mA (field-selectable ranges per cell constant)
Cell ConstantsIntegral systems with 0.01 / 0.1 / 1.0 / 10.0 / 20.0 cm⁻¹ electrodes
EnclosureNEMA 4X / IP65 PBT electronics enclosure
Temp CompPT-1000 RTD; EasyCal automatic test-solution recognition
TransmittersPairs with GF 9900 / 9950; dual-channel 2850-63 for 9950 I/O optimization
Operating Temperature−10…+85 °C (electronics)
ApplicationRO, DI, demineralizer, scrubber, cooling tower, aquatic life support
DocumentGFPS Type 2850 datasheet + 3-2850.090 operating instructions