Endress+Hauser

Endress+Hauser Smartec CLD18 Compact Conductivity Device

SKU · 47562 · Smartec CLD18 Compact Conductivity Device · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Smartec CLD18: inductive cond; 200 μS/cm–1000 mS/cm; −10…130 °C; 4–20 mA/IO-Link. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring Principle
Inductive (toroidal) conductivity
Conductivity Range
Recommended 200 μS/cm to 1000 mS/cm (uncompensated)
Temperature Range Meas
−10 to 130 °C (14 to 266 °F)
Measured Error
Conductivity ±(2.0% of measured value + 20 μS/cm); temperature ±1.5 K
Repeatability
Conductivity max 0.5% of measured value ±5 μS/cm ±2 digits
Outputs
Conductivity and temperature 0/4–20 mA galvanically isolated; optional IO-Link 1.1.3
Download datasheet PDF

Fits compact inductive conductivity where you need an Endress+Hauser Smartec CLD18. Toroidal conductivity device for about 200 μS/cm to 1000 mS/cm, temperature −10 to 130 °C, measured error ±(2.0% of measured value + 20 μS/cm), with galvanically isolated 0/4–20 mA conductivity and temperature outputs and optional IO-Link 1.1.3.

Key advantages

  • Principle — Inductive (toroidal)
  • Range — 200 μS/cm to 1000 mS/cm recommended
  • Temperature — −10 to 130 °C
  • Outputs — Cond + T 0/4–20 mA isolated
  • IO-Link — Optional 1.1.3

Typical applications

  • CIP conductivity.
  • Compact process cond.
  • Food / beverage inductive cond.

Selection guide

  • IO-Link vs analog
  • Mounting
  • Range band

Common mistakes

  • Below 200 μS/cm without care.
  • Air in toroid.
  • Ignoring +20 μS/cm floor.

When to RFQ / what to tell us

  1. Output/mounting.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU47562
BrandEndress+Hauser
ModelSmartec CLD18 Compact Conductivity Device
Product typeConductivity Device
Measuring principleInductive (toroidal) conductivity
Conductivity rangeRecommended 200 μS/cm to 1000 mS/cm (uncompensated)
Temperature range−10 to 130 °C (14 to 266 °F)
Measured errorConductivity ±(2.0% of measured value + 20 μS/cm); temperature ±1.5 K
RepeatabilityConductivity max 0.5% of measured value ±5 μS/cm ±2 digits
OutputsConductivity and temperature 0/4–20 mA galvanically isolated; optional IO-Link 1.1.3

Documents

FAQ

Q: Principle? A: Inductive toroidal.

Q: Outputs? A: Cond + T 0/4–20 mA; IO-Link option.

Q: What should I send for a quote? A: Output/mounting, quantity, ship-to.

Links

ParameterValue
Measuring PrincipleInductive (toroidal) conductivity
Conductivity RangeRecommended 200 μS/cm to 1000 mS/cm (uncompensated)
Temperature Range Meas−10 to 130 °C (14 to 266 °F)
Measured ErrorConductivity ±(2.0% of measured value + 20 μS/cm); temperature ±1.5 K
RepeatabilityConductivity max 0.5% of measured value ±5 μS/cm ±2 digits
OutputsConductivity and temperature 0/4–20 mA galvanically isolated; optional IO-Link 1.1.3
Ingress ProtectionIP69 (EN 40050); NEMA Type 6P
Response TimeConductivity t95 < 1.5 s; temperature t90 < 20 s
Sensor MaterialFood-safe PEEK; hygienic design EHEDG / 3-A class
HousingStainless steel 1.4308 or plastic PBT GF; high-pressure steam cleanable
WeightStainless max 1.870 kg; plastic max 1.070 kg
ApplicationsBeverage phase separation, CIP concentration control, industrial water, pickling rinse
DocumentTI01080C/07/EN/06.21; BA01149CEN