Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Proline Promass F 300 Coriolis Flow Meter
Quote on request
No online payment · add lines to RFQ BOM
E+H Promass F 300: Coriolis; to 2.2M kg/h; ±0.10%/±0.05% liquid; DN 8–250. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10")
Accuracy
Mass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³
Output
Up to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server
Supply
Per Proline 300 transmitter power supply order code (AC/DC variants in TI)
Process connection
Flanges / hygienic / threaded options per TI process connections
Wetted parts
Measuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301
Fits high-performance Coriolis metering where you need an Endress+Hauser Proline Promass F 300—mass flow to about 2,200,000 kg/h on DN 8 to 250, liquid mass accuracy ±0.10% standard (±0.05% PremiumCal), and Proline 300 multi-protocol I/O.
Key advantages
- Range — 0 to about 2,200,000 kg/h
- DN — 8 to 250 (⅜ to 10")
- Accuracy — Liquid mass ±0.10% std / ±0.05% PremiumCal
- I/O — Up to 3 combinable outputs; HART/fieldbus/Ethernet
- Tubes — 904L / 316L / Alloy C22 options
Typical applications
- Custody-oriented liquid mass.
- Chemical batching.
- Gas mass where specified.
Selection guide
- DN / PremiumCal
- Wetted materials
- I/O / protocol
Common mistakes
- Wrong tube material.
- Two-phase without care.
- Missing zero adjustment.
When to RFQ / what to tell us
- DN/materials/I/O.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 45664 |
| Brand | Endress+Hauser |
| Model | Proline Promass F 300 |
| Product type | Coriolis Flow Meter |
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10") |
| Accuracy | Mass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³ |
| Output signal | Up to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server |
| Wetted materials | Measuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301 |
| Process connection | Flanges / hygienic / threaded options |
| IP rating | Transmitter/sensor IP ratings |
Documents
FAQ
Q: Liquid mass accuracy? A: ±0.10% standard; ±0.05% PremiumCal.
Q: DN? A: 8 to 250.
Q: What should I send for a quote? A: DN/materials/I/O, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | 0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10") |
| Accuracy | Mass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³ |
| Output | Up to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server |
| Supply | Per Proline 300 transmitter power supply order code (AC/DC variants in TI) |
| Process connection | Flanges / hygienic / threaded options per TI process connections |
| Wetted parts | Measuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301 |
| Housing | Proline 300 dual-compartment: coated aluminum AlSi10Mg, stainless hygienic 1.4404, or cast stainless 1.4409 |
| Protection | Transmitter/sensor IP ratings per TI Degree of protection (typically IP66/67 class) |
| Media temperature | Standard −50 to +150 °C; options to +240 / +350 °C; cryogenic option −196 to +150 °C |
| Ambient temperature | Per TI Ambient temperature range tables (transmitter/sensor pairing) |
| Display | 4-line illuminated graphic LCD with touch control; remote display available |
| Communication | HART; PROFIBUS; Modbus; PROFINET; EtherNet/IP; OPC-UA; WLAN; web server |
| Approvals | CE; UKCA; Ex approvals per order code; Heartbeat Technology |
| Notes | Specs from E+H TI01221D/06/EN/14.25-00 (2025-12-01) and product page specs-at-a-glance. |
| Process Pressure | Max PN 100 / Class 600 / 63K |