Endress+Hauser

Endress+Hauser Proline Promass F 300 Coriolis Flow Meter

SKU · 45664 · Proline Promass F 300 · Brand: Endress+Hauser
Available
Quote on request
No online payment · add lines to RFQ BOM

E+H Promass F 300: Coriolis; to 2.2M kg/h; ±0.10%/±0.05% liquid; DN 8–250. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10")
Accuracy
Mass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³
Output
Up to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server
Supply
Per Proline 300 transmitter power supply order code (AC/DC variants in TI)
Process connection
Flanges / hygienic / threaded options per TI process connections
Wetted parts
Measuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301
Download datasheet PDF

Fits high-performance Coriolis metering where you need an Endress+Hauser Proline Promass F 300—mass flow to about 2,200,000 kg/h on DN 8 to 250, liquid mass accuracy ±0.10% standard (±0.05% PremiumCal), and Proline 300 multi-protocol I/O.

Key advantages

  • Range — 0 to about 2,200,000 kg/h
  • DN — 8 to 250 (⅜ to 10")
  • Accuracy — Liquid mass ±0.10% std / ±0.05% PremiumCal
  • I/O — Up to 3 combinable outputs; HART/fieldbus/Ethernet
  • Tubes — 904L / 316L / Alloy C22 options

Typical applications

  • Custody-oriented liquid mass.
  • Chemical batching.
  • Gas mass where specified.

Selection guide

  • DN / PremiumCal
  • Wetted materials
  • I/O / protocol

Common mistakes

  • Wrong tube material.
  • Two-phase without care.
  • Missing zero adjustment.

When to RFQ / what to tell us

  1. DN/materials/I/O.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU45664
BrandEndress+Hauser
ModelProline Promass F 300
Product typeCoriolis Flow Meter
Measuring range0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10")
AccuracyMass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³
Output signalUp to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server
Wetted materialsMeasuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301
Process connectionFlanges / hygienic / threaded options
IP ratingTransmitter/sensor IP ratings

Documents

FAQ

Q: Liquid mass accuracy? A: ±0.10% standard; ±0.05% PremiumCal.

Q: DN? A: 8 to 250.

Q: What should I send for a quote? A: DN/materials/I/O, quantity, ship-to.

Links

ParameterValue
Measuring range0 to 2 200 000 kg/h (0 to 80 840 lb/min); DN 8 to 250 (⅜ to 10")
AccuracyMass flow liquid ±0.10% standard / ±0.05% PremiumCal; volume liquid ±0.10%; gas mass ±0.25%; density liquid ±0.0005 g/cm³
OutputUp to 3 freely combinable I/Os; current/pulse/frequency/status; HART/PROFIBUS/Modbus/PROFINET/EtherNet/IP/OPC-UA; WLAN/web server
SupplyPer Proline 300 transmitter power supply order code (AC/DC variants in TI)
Process connectionFlanges / hygienic / threaded options per TI process connections
Wetted partsMeasuring tubes 1.4539 (904L) / 1.4404 (316/316L) / Alloy C22 2.4602; connections 1.4404 / Alloy C22 / 1.4301
HousingProline 300 dual-compartment: coated aluminum AlSi10Mg, stainless hygienic 1.4404, or cast stainless 1.4409
ProtectionTransmitter/sensor IP ratings per TI Degree of protection (typically IP66/67 class)
Media temperatureStandard −50 to +150 °C; options to +240 / +350 °C; cryogenic option −196 to +150 °C
Ambient temperaturePer TI Ambient temperature range tables (transmitter/sensor pairing)
Display4-line illuminated graphic LCD with touch control; remote display available
CommunicationHART; PROFIBUS; Modbus; PROFINET; EtherNet/IP; OPC-UA; WLAN; web server
ApprovalsCE; UKCA; Ex approvals per order code; Heartbeat Technology
NotesSpecs from E+H TI01221D/06/EN/14.25-00 (2025-12-01) and product page specs-at-a-glance.
Process PressureMax PN 100 / Class 600 / 63K