Image unavailable
Image unavailable
MadgeTech
MadgeTech RHTemp1000IS IS Humidity Logger
Quote on request
No online payment · add lines to RFQ BOM
RHTemp1000IS: −40…+80 °C; 0–100 %RH; IS Class I–III; 316 SS. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Approvals
SGS IS Class I/II/III Div 1 Groups A–G; Div 2 Groups A–D,F,G; T4A
Temperature Range
-40 °C to +80 °C (-40 °F to +176 °F)
Temperature Accuracy
±0.5 °C (0 °C to 50 °C)
Humidity Range
0 %RH to 100 %RH (non-condensing)
Humidity Accuracy
±3.0 %RH maximum
Memory
32,640 readings per channel
Fits hazardous-area humidity and temperature logging where you need a MadgeTech RHTemp1000IS—−40…+80 °C, 0–100 %RH, with SGS IS Class I/II/III Div 1 approvals and 316 SS / Radel housing.
Key advantages
- T — −40…+80 °C; ±0.5 °C (0…50 °C)
- RH — 0–100 %RH; ±3.0 %RH max
- Memory — 32,640 readings/channel
- Battery — ~2 years at 15 min rate
- Approvals — IS Class I/II/III Div 1 Groups A–G class
Typical applications
- Hazloc environmental logging.
- Pharma / chemical RH monitoring.
- Compact stainless RH/T studies.
Selection guide
- Confirm IS area classification
- Reading rate vs battery
- Dock/software
Common mistakes
- Using outside listed IS groups.
- Condensing RH beyond non-condensing guidance.
- Wrong download dock.
When to RFQ / what to tell us
- Area class, accessories.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 35187 |
| Brand | MadgeTech |
| Model | RHTemp1000IS Intrinsically Safe Humidity and Temperature Data Logger |
| Product type | Humidity Temperature Data Logger |
| Temperature range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature accuracy | ±0.5 °C (0 °C to 50 °C) |
| Humidity range | 0 %RH to 100 %RH (non-condensing) |
| Humidity accuracy | ±3.0 %RH maximum |
| Memory | 32,640 readings per channel |
| Approvals | SGS IS Class I/II/III Div 1 Groups A–G; Div 2 Groups A–D,F,G; T4A |
Documents
FAQ
Q: IS rated? A: Yes — intrinsically safe Class I/II/III Div 1 class per OEM.
Q: RH accuracy? A: ±3.0 %RH maximum.
Q: What should I send for a quote? A: Area class, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Approvals | SGS IS Class I/II/III Div 1 Groups A–G; Div 2 Groups A–D,F,G; T4A |
| Temperature Range | -40 °C to +80 °C (-40 °F to +176 °F) |
| Temperature Accuracy | ±0.5 °C (0 °C to 50 °C) |
| Humidity Range | 0 %RH to 100 %RH (non-condensing) |
| Humidity Accuracy | ±3.0 %RH maximum |
| Memory | 32,640 readings per channel |
| Reading Rate | 1 s to 24 h |
| Battery Life | 2 years typical at 15 min reading rate |
| Material | 316 stainless steel / Radel |
| Dimensions | 1.67 in × 0.97 in dia. (42.3 × 24.6 mm) |