Image unavailable
Image unavailable
MadgeTech
MadgeTech RHTemp101A Humidity Temperature Logger
Quote on request
No online payment · add lines to RFQ BOM
RHTemp101A: −40…+80 °C; 0–95 %RH; ~1M readings/ch; compact. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
Compact humidity and temperature data logger (RHTemp101A)
Temperature Range
−40…+80 °C (−40…+176 °F)
Temperature Accuracy
±0.5 °C (0…55 °C); ±1.0 °C outside that band
Temperature Resolution
0.01 °C (0.02 °F)
Humidity Range
0…95 %RH
Humidity Accuracy
±3.0 %RH (calibrated)
Fits compact standalone RH/T logging where you need a MadgeTech RHTemp101A—−40…+80 °C with ±0.5 °C (0…55 °C) and 0–95 %RH at ±3.0 %RH calibrated, with over a million readings per channel.
Key advantages
- T — −40…+80 °C; ±0.5 °C (0…55 °C)
- RH — 0–95 %RH; ±3.0 %RH calibrated
- Resolution — 0.01 °C; 0.1 %RH
- Memory — 1,047,552 readings/channel
- Rate — 1 s to 24 h
Typical applications
- Room RH/T mapping.
- Shipment / storage studies.
- Compact multi-start logging.
Selection guide
- Start/stop mode
- IFC interface
- Reading rate
Common mistakes
- Condensing RH.
- Expecting wireless (use Element for that).
- Wrong download interface.
When to RFQ / what to tell us
- Accessories, quantity.
- Ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 35193 |
| Brand | MadgeTech |
| Model | RHTemp101A Humidity and Temperature Data Logger |
| Product type | Humidity Temperature Data Logger |
| Type | Compact humidity and temperature data logger (RHTemp101A) |
| Temperature range | −40…+80 °C (−40…+176 °F) |
| Temperature accuracy | ±0.5 °C (0…55 °C); ±1.0 °C outside that band |
| Humidity range | 0…95 %RH |
| Humidity accuracy | ±3.0 %RH (calibrated) |
| Memory | 1,047,552 readings per channel; memory wrap; 349,184 in multi start/stop |
Documents
FAQ
Q: Memory? A: About 1.05 million readings per channel.
Q: T accuracy? A: ±0.5 °C from 0…55 °C.
Q: What should I send for a quote? A: Quantity, accessories, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | Compact humidity and temperature data logger (RHTemp101A) |
| Temperature Range | −40…+80 °C (−40…+176 °F) |
| Temperature Accuracy | ±0.5 °C (0…55 °C); ±1.0 °C outside that band |
| Temperature Resolution | 0.01 °C (0.02 °F) |
| Humidity Range | 0…95 %RH |
| Humidity Accuracy | ±3.0 %RH (calibrated) |
| Humidity Resolution | 0.1 %RH |
| Memory | 1,047,552 readings per channel; memory wrap; 349,184 in multi start/stop |
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Battery | 3.6 V lithium user-replaceable; ~10 years typical at 15-minute rate |
| Document | RHTemp101A Specification Sheet + Product User Guide (MadgeTech downloads) |
| Application | Warehouse/museum/HVAC monitoring; medical/pharma; HACCP; general RH/T logging |