MadgeTech

MadgeTech OctThermoVault Oven Temperature Data Logger

SKU · 35197 · OctThermoVault · Brand: MadgeTech
Available
Quote on request
No online payment · add lines to RFQ BOM

MadgeTech OctThermoVault: 8-ch TC oven logger; to ~350 °C/~25 min; obsolete→ThermoVaultX. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Type
8-channel oven temperature data logger in thermal barrier (OctThermoVault)
Oem Status
Obsolete July 2020; replacement ThermoVaultX series
Channels
8 internal ambient + 8 remote thermocouple channels
Thermocouples
J, K, T, E, R, S, B, N; Type K probes included in system kits
Internal Temp
−20…+60 °C; resolution 0.01 °C; accuracy ±0.5 °C (0…+50 °C)
Memory
16,368 readings/channel (130,944 total with all 8 enabled)
Download datasheet PDF

Fits oven profiling with a thermal barrier where you need a MadgeTech OctThermoVault. Eight-channel oven temperature data logger (8 internal ambient + 8 remote thermocouple channels) supporting J/K/T/E/R/S/B/N with Type K probes in system kits, memory 16,368 readings/channel, rates from 4 readings/s, and exposure up to about 350 °C for about 25 minutes when properly sealed. OEM status: obsolete July 2020; replacement ThermoVaultX series.

Key advantages

  • Channels — 8 TC + internal ambient
  • TC types — J/K/T/E/R/S/B/N
  • Memory — 16,368 readings/channel
  • Exposure — ~350 °C / ~25 min sealed
  • Successor — ThermoVaultX series

Typical applications

  • Oven temperature profiling.
  • Thermal barrier surveys.
  • Legacy OctThermoVault support.

Selection guide

  • Successor vs legacy
  • TC type / probes
  • Exposure profile

Common mistakes

  • Ordering obsolete without successor plan.
  • Exceeding sealed exposure envelope.
  • Wrong TC type.

When to RFQ / what to tell us

  1. Legacy vs ThermoVaultX.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU35197
BrandMadgeTech
ModelOctThermoVault
Product typeOven Temperature Data Logger
Type8-channel oven temperature data logger in thermal barrier (OctThermoVault)
OEM statusObsolete July 2020; replacement ThermoVaultX series
Channels8 internal ambient + 8 remote thermocouple channels
ThermocouplesJ, K, T, E, R, S, B, N; Type K probes included in system kits
Internal temp−20…+60 °C; resolution 0.01 °C; accuracy ±0.5 °C (0…+50 °C)
Memory16,368 readings/channel (130,944 total with all 8 enabled)
Reading rate4 readings/s up to slower software-programmable rates
ExposureUp to ~350 °C for ~25 minutes when properly sealed (oven profiling)

Documents

FAQ

Q: Obsolete? A: Yes (July 2020); ThermoVaultX replaces.

Q: Exposure? A: Up to ~350 °C for ~25 min sealed.

Q: What should I send for a quote? A: Legacy vs ThermoVaultX, quantity, ship-to.

Links

ParameterValue
Type8-channel oven temperature data logger in thermal barrier (OctThermoVault)
Oem StatusObsolete July 2020; replacement ThermoVaultX series
Channels8 internal ambient + 8 remote thermocouple channels
ThermocouplesJ, K, T, E, R, S, B, N; Type K probes included in system kits
Internal Temp−20…+60 °C; resolution 0.01 °C; accuracy ±0.5 °C (0…+50 °C)
Memory16,368 readings/channel (130,944 total with all 8 enabled)
Reading Rate4 readings/s up to slower software-programmable rates
ExposureUp to ~350 °C for ~25 minutes when properly sealed (oven profiling)
Battery~18 months typical life
ApplicationPowder/wet-coating/batch/conveyor oven temperature profiling
DocumentOctThermoVault_DS.pdf + QuadThermoVault-OctThermoVault_PIC.pdf
Start ModesSoftware immediate or delay start up to six months