Image unavailable
Image unavailable
HOBO Data Loggers by Onset
HOBO Onset RX Runtime Smart Sensor
Quote on request
No online payment · add lines to RFQ BOM
HOBO RX Runtime S-RTA-M006: % ON / contact time; 1 s sample; RX stations. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Type
HOBO RX Runtime Smart Sensor (S-RTA-M006)
Function
Measures percent ON of AC-powered devices (with AC current switch) and time ON of contact closures
Compatibility
HOBO RX stations (plug-and-play smart sensor)
Input Sampling Period
1 second
External Contact Input
Solid-state switch closure, logic-driven voltage, or open/closed mechanical switch (preferred normally open)
Logic Levels
Logic 0 less than 0.4 V DC; Logic 1 greater than 2.5 V DC; input range 0 to 3.6 V
Fits runtime logging on HOBO RX stations where you need an Onset RX Runtime Smart Sensor (S-RTA-M006). Plug-and-play smart sensor measuring percent ON of AC-powered devices (with AC current switch) and time ON of contact closures, 1-second input sampling, supporting solid-state switch closure, logic-driven voltage or open/closed mechanical switch (normally open preferred).
Key advantages
- Function — % ON and contact time ON
- Sample — 1 second input period
- Host — HOBO RX stations plug-and-play
- Inputs — AC current switch / contact / logic
- PN — S-RTA-M006
Typical applications
- Equipment runtime logging.
- Pump / fan ON-time.
- RX station expansions.
Selection guide
- AC switch vs dry contact
- Cable length
- RX station model
Common mistakes
- Wrong contact polarity preference.
- Missing AC current switch.
- Incompatible station.
When to RFQ / what to tell us
- Station/accessories.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 49334 |
| Brand | HOBO Data Loggers by Onset |
| Model | RX Runtime Smart Sensor |
| Product type | Runtime Sensor |
| Type | HOBO RX Runtime Smart Sensor (S-RTA-M006) |
| Function | Measures percent ON of AC-powered devices (with AC current switch) and time ON of contact closures |
| Compatibility | HOBO RX stations (plug-and-play smart sensor) |
| Input sampling period | 1 second |
| External contact input | Solid-state switch closure, logic-driven voltage, or open/closed mechanical switch (preferred normally open) |
Documents
FAQ
Q: Sample period? A: 1 second.
Q: PN? A: S-RTA-M006.
Q: What should I send for a quote? A: Station/accessories, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Type | HOBO RX Runtime Smart Sensor (S-RTA-M006) |
| Function | Measures percent ON of AC-powered devices (with AC current switch) and time ON of contact closures |
| Compatibility | HOBO RX stations (plug-and-play smart sensor) |
| Input Sampling Period | 1 second |
| External Contact Input | Solid-state switch closure, logic-driven voltage, or open/closed mechanical switch (preferred normally open) |
| Logic Levels | Logic 0 less than 0.4 V DC; Logic 1 greater than 2.5 V DC; input range 0 to 3.6 V |
| Operating Temperature | -40 to 75 C (-40 to 167 F) |
| Cable Length | Overall about 6.5 m (21.3 ft); smart-sensor cable portion about 50 cm |
| Channels | 2 data channels (percent runtime 12-bit; seconds runtime 16-bit) |
| Weight | About 200 g (7.06 oz) |
| Time Accuracy | +/-4 seconds due to possible clock differences vs station |
| Document | HOBO S-RTA-M006 sensor specifications (OEM content via authorized distributor datasheet mirror; OEM site product HTML Cloudflare this pass; OEM product PNG fetched) |