Fluke Calibration

Fluke Calibration 1551A/1552A Stik Thermometer

SKU · 34972 · 1551A / 1552A Stik · Brand: Fluke Calibration
Available
Quote on request
No online payment · add lines to RFQ BOM

Reference Stik thermometer: ±0.05 °C, 1551A −50…160 °C / 1552A −80…300 °C, Ex ib. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
1551A Ex: −50 to 160 °C; 1552A Ex: −80 to 300 °C
Accuracy
±0.05 °C (±0.09 °F) over full range (1 year)
Protection
IP50 enclosure rating (brochure)
Approvals
ATEX; IECEx; NVLAP/NIST cal
Hazardous area
Ex ib IIB T4 Gb (ATEX/IECEx); intrinsically safe
Sensor type
1551A: 100 Ω thin-film RTD; 1552A: 100 Ω wire-wound PRT
Download datasheet PDF

Fits field and lab reference temperature checks where you need a handheld intrinsically safe Stik thermometer at ±0.05 °C over the full probe range (1551A Ex −50…160 °C thin-film RTD; 1552A Ex −80…300 °C wire-wound PRT).

Key advantages

  • ±0.05 °C full-range accuracy — 1-year published reference accuracy on both Stik models.
  • Two probe bands — 1551A Ex −50…160 °C thin-film RTD; 1552A Ex −80…300 °C wire-wound PRT.
  • Intrinsically safe — Ex ib IIB T4 Gb (ATEX/IECEx) for classified area checks.
  • Long battery life — ~300 h continuous (backlight off) on 3×AAA; optional 10,000-point logging.

Typical applications

  • Field reference checks replacing mercury thermometers.
  • Intrinsically safe plant rounds needing ±0.05 °C class accuracy.
  • Lab and shop reference work with optional datalogging.

Selection guide

  • Models — 1551A Ex: −50 to 160 °C, 100 Ω thin-film RTD; 1552A Ex: −80 to 300 °C, 100 Ω wire-wound PRT.
  • Accuracy — ±0.05 °C (±0.09 °F) over full range (1 year).
  • Resolution — Selectable 0.1 / 0.01 / 0.001 °C (default 0.01).
  • Probe hysteresis — ±0.01 °C; response ~20 s typical (probe diameter dependent).
  • Display units — °C or °F.
  • Operating temperature (readout) — −10 to 50 °C (14 to 122 °F).
  • IP / enclosure — IP50 enclosure rating (brochure).
  • Battery — Approximately 300 hours continuous (backlight off); 3×AAA.
  • Data logging — Optional up to 10,000 time-stamped readings.
  • Hazardous area — Ex ib IIB T4 Gb (ATEX/IECEx); intrinsically safe.

Common mistakes

  • Ordering 1551A when the process span goes below −50 °C or above 160 °C — use 1552A Ex (−80…300 °C) for the wider class.
  • Treating default 0.01 °C resolution as the only option — resolution is selectable 0.1 / 0.01 / 0.001 °C.
  • Ignoring Ex ib IIB T4 Gb limits when the area classification differs.
  • Assuming data logging is included — optional up to 10,000 time-stamped readings; state need on the RFQ.
  • Expecting IP67 wet washdown — brochure lists IP50 enclosure rating.
  • Calibration instruments · Calibration buying guide

When to RFQ / what to tell us

  1. Model (1551A Ex vs 1552A Ex), probe length/diameter class, and display resolution.
  2. Hazardous-area need (Ex ib IIB T4 Gb) and ambient for the readout (−10…50 °C).
  3. Optional data logging yes/no; quantity, ship-to, and any QA docs beyond included NVLAP/NIST cal.

Request a Quote · Get selection help

Specs

SpecValue
SKU34972
BrandFluke Calibration
Model1551A / 1552A Stik
Product typereference_thermometer
Measuring range1551A Ex: −50 to 160 °C; 1552A Ex: −80 to 300 °C
Accuracy±0.05 °C (±0.09 °F) over full range (1 year)
Sensor type1551A: 100 Ω thin-film RTD; 1552A: 100 Ω wire-wound PRT
ResolutionSelectable 0.1 / 0.01 / 0.001 °C (default 0.01)
Response timeApproximately 20 s typical (probe diameter dependent)
Probe hysteresis±0.01 °C
Display units°C or °F
Operating temperatureReadout −10 to 50 °C (14 to 122 °F)
IP ratingIP50 enclosure rating (brochure)
Battery lifeApproximately 300 hours continuous (backlight off); 3×AAA
Data loggingOptional up to 10,000 time-stamped readings
Hazardous areaEx ib IIB T4 Gb (ATEX/IECEx); intrinsically safe
CalibrationNVLAP-accredited, NIST-traceable calibration included
Sheath materialStainless steel probe sheath
ApprovalsATEX; IECEx; NVLAP/NIST cal

Documents

FAQ

Q: What is the difference between 1551A and 1552A? A: 1551A Ex covers −50…160 °C with a thin-film RTD; 1552A Ex covers −80…300 °C with a wire-wound PRT. Both are ±0.05 °C (1 year) per the datasheet.

Q: Is it intrinsically safe? A: Yes — Ex ib IIB T4 Gb (ATEX/IECEx) is listed. Confirm your area classification on the RFQ.

Q: What should I send for a quote? A: Model, probe class, resolution, Ex need, logging yes/no, quantity. Compatible with systems using Fluke Calibration 1551A/1552A Stik — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range1551A Ex: −50 to 160 °C; 1552A Ex: −80 to 300 °C
Accuracy±0.05 °C (±0.09 °F) over full range (1 year)
ProtectionIP50 enclosure rating (brochure)
ApprovalsATEX; IECEx; NVLAP/NIST cal
Hazardous areaEx ib IIB T4 Gb (ATEX/IECEx); intrinsically safe
Sensor type1551A: 100 Ω thin-film RTD; 1552A: 100 Ω wire-wound PRT
ResolutionSelectable 0.1 / 0.01 / 0.001 °C (default 0.01)
Response TimeApproximately 20 s typical (probe diameter dependent)
Probe Hysteresis±0.01 °C
Display Units°C or °F
Operating TemperatureReadout −10 to 50 °C (14 to 122 °F)
Battery LifeApproximately 300 hours continuous (backlight off); 3×AAA
Data LoggingOptional up to 10,000 time-stamped readings
CalibrationNVLAP-accredited, NIST-traceable calibration included
Sheath MaterialStainless steel probe sheath