Fluke Calibration 1551A/1552A Stik Thermometer
Reference Stik thermometer: ±0.05 °C, 1551A −50…160 °C / 1552A −80…300 °C, Ex ib. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits field and lab reference temperature checks where you need a handheld intrinsically safe Stik thermometer at ±0.05 °C over the full probe range (1551A Ex −50…160 °C thin-film RTD; 1552A Ex −80…300 °C wire-wound PRT).
Key advantages
- ±0.05 °C full-range accuracy — 1-year published reference accuracy on both Stik models.
- Two probe bands — 1551A Ex −50…160 °C thin-film RTD; 1552A Ex −80…300 °C wire-wound PRT.
- Intrinsically safe — Ex ib IIB T4 Gb (ATEX/IECEx) for classified area checks.
- Long battery life — ~300 h continuous (backlight off) on 3×AAA; optional 10,000-point logging.
Typical applications
- Field reference checks replacing mercury thermometers.
- Intrinsically safe plant rounds needing ±0.05 °C class accuracy.
- Lab and shop reference work with optional datalogging.
Selection guide
- Models — 1551A Ex: −50 to 160 °C, 100 Ω thin-film RTD; 1552A Ex: −80 to 300 °C, 100 Ω wire-wound PRT.
- Accuracy — ±0.05 °C (±0.09 °F) over full range (1 year).
- Resolution — Selectable 0.1 / 0.01 / 0.001 °C (default 0.01).
- Probe hysteresis — ±0.01 °C; response ~20 s typical (probe diameter dependent).
- Display units — °C or °F.
- Operating temperature (readout) — −10 to 50 °C (14 to 122 °F).
- IP / enclosure — IP50 enclosure rating (brochure).
- Battery — Approximately 300 hours continuous (backlight off); 3×AAA.
- Data logging — Optional up to 10,000 time-stamped readings.
- Hazardous area — Ex ib IIB T4 Gb (ATEX/IECEx); intrinsically safe.
Common mistakes
- Ordering 1551A when the process span goes below −50 °C or above 160 °C — use 1552A Ex (−80…300 °C) for the wider class.
- Treating default 0.01 °C resolution as the only option — resolution is selectable 0.1 / 0.01 / 0.001 °C.
- Ignoring Ex ib IIB T4 Gb limits when the area classification differs.
- Assuming data logging is included — optional up to 10,000 time-stamped readings; state need on the RFQ.
- Expecting IP67 wet washdown — brochure lists IP50 enclosure rating.
- Calibration instruments · Calibration buying guide
When to RFQ / what to tell us
- Model (1551A Ex vs 1552A Ex), probe length/diameter class, and display resolution.
- Hazardous-area need (Ex ib IIB T4 Gb) and ambient for the readout (−10…50 °C).
- Optional data logging yes/no; quantity, ship-to, and any QA docs beyond included NVLAP/NIST cal.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 34972 |
| Brand | Fluke Calibration |
| Model | 1551A / 1552A Stik |
| Product type | reference_thermometer |
| Measuring range | 1551A Ex: −50 to 160 °C; 1552A Ex: −80 to 300 °C |
| Accuracy | ±0.05 °C (±0.09 °F) over full range (1 year) |
| Sensor type | 1551A: 100 Ω thin-film RTD; 1552A: 100 Ω wire-wound PRT |
| Resolution | Selectable 0.1 / 0.01 / 0.001 °C (default 0.01) |
| Response time | Approximately 20 s typical (probe diameter dependent) |
| Probe hysteresis | ±0.01 °C |
| Display units | °C or °F |
| Operating temperature | Readout −10 to 50 °C (14 to 122 °F) |
| IP rating | IP50 enclosure rating (brochure) |
| Battery life | Approximately 300 hours continuous (backlight off); 3×AAA |
| Data logging | Optional up to 10,000 time-stamped readings |
| Hazardous area | Ex ib IIB T4 Gb (ATEX/IECEx); intrinsically safe |
| Calibration | NVLAP-accredited, NIST-traceable calibration included |
| Sheath material | Stainless steel probe sheath |
| Approvals | ATEX; IECEx; NVLAP/NIST cal |
Documents
FAQ
Q: What is the difference between 1551A and 1552A? A: 1551A Ex covers −50…160 °C with a thin-film RTD; 1552A Ex covers −80…300 °C with a wire-wound PRT. Both are ±0.05 °C (1 year) per the datasheet.
Q: Is it intrinsically safe? A: Yes — Ex ib IIB T4 Gb (ATEX/IECEx) is listed. Confirm your area classification on the RFQ.
Q: What should I send for a quote? A: Model, probe class, resolution, Ex need, logging yes/no, quantity. Compatible with systems using Fluke Calibration 1551A/1552A Stik — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | 1551A Ex: −50 to 160 °C; 1552A Ex: −80 to 300 °C |
| Accuracy | ±0.05 °C (±0.09 °F) over full range (1 year) |
| Protection | IP50 enclosure rating (brochure) |
| Approvals | ATEX; IECEx; NVLAP/NIST cal |
| Hazardous area | Ex ib IIB T4 Gb (ATEX/IECEx); intrinsically safe |
| Sensor type | 1551A: 100 Ω thin-film RTD; 1552A: 100 Ω wire-wound PRT |
| Resolution | Selectable 0.1 / 0.01 / 0.001 °C (default 0.01) |
| Response Time | Approximately 20 s typical (probe diameter dependent) |
| Probe Hysteresis | ±0.01 °C |
| Display Units | °C or °F |
| Operating Temperature | Readout −10 to 50 °C (14 to 122 °F) |
| Battery Life | Approximately 300 hours continuous (backlight off); 3×AAA |
| Data Logging | Optional up to 10,000 time-stamped readings |
| Calibration | NVLAP-accredited, NIST-traceable calibration included |
| Sheath Material | Stainless steel probe sheath |