Image unavailable
Image unavailable
Intempco
Intempco DTG53 / DTG54 Digital Temperature Gauge
Quote on request
No online payment · add lines to RFQ BOM
DTG53/54: Pt1000 Class A; LCD; Li AA ≥5 yr; IP67/NEMA 4X. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Process connection
DTG53 adjustable compression fitting; DTG54 welded 1/2 in NPT options
Display
4-digit 1/2 in (12.7 mm) LCD; 0.1 degree resolution; C or F factory set
Type
Intempco DTG53/DTG54 battery-powered LCD digital temperature gauge with Pt1000 Class A RTD
Sensor
Pt-1000 Ohm RTD Class A (DIN IEC 60751); all wetted parts stainless steel 316/316L
Battery Life
Two 3.6 V AA lithium; minimum 5 years continuous operation
Enclosure
IP67 / NEMA 4X waterproof stainless housing
Fits battery-powered local temperature indication where you need an Intempco DTG53 or DTG54—Pt1000 Class A RTD, 4-digit ½-inch LCD at 0.1° resolution, dual 3.6 V AA lithium cells for ≥5 years continuous operation, and IP67 / NEMA 4X stainless housing.
Key advantages
- Sensor — Pt1000 Class A (DIN IEC 60751); 316/316L wetted
- Display — 4-digit 12.7 mm LCD; 0.1°; °C or °F factory set
- Battery — 2× 3.6 V AA lithium; ≥5 years continuous
- Enclosure — IP67 / NEMA 4X stainless
- Platform — DTG53 / DTG54 battery gauges
Typical applications
- Washdown local temperature.
- Battery sites without loop power.
- Sanitary / stainless indication.
Selection guide
- DTG53 vs DTG54 options
- Probe length
- °C vs °F
Common mistakes
- Expecting 4–20 mA (use DTG03).
- Alkaline AA instead of lithium 3.6 V.
- Ignoring IP67 cable gland plan.
When to RFQ / what to tell us
- Model, probe.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 39032 |
| Brand | Intempco |
| Model | DTG53 / DTG54 Digital Temperature Gauge |
| Product type | Digital Temperature Gauge |
| Type | Intempco DTG53/DTG54 battery-powered LCD digital temperature gauge with Pt1000 Class A RTD |
| Display | 4-digit 1/2 in (12.7 mm) LCD; 0.1 degree resolution; C or F factory set |
| Sensor | Pt-1000 Ohm RTD Class A (DIN IEC 60751); all wetted parts stainless steel 316/316L |
| Battery life | Two 3.6 V AA lithium; minimum 5 years continuous operation |
| Enclosure | IP67 / NEMA 4X waterproof stainless housing |
Documents
FAQ
Q: Battery life? A: Minimum about 5 years continuous on dual 3.6 V AA lithium.
Q: Sensor? A: Pt1000 Class A RTD.
Q: What should I send for a quote? A: Model/probe, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Process connection | DTG53 adjustable compression fitting; DTG54 welded 1/2 in NPT options |
| Display | 4-digit 1/2 in (12.7 mm) LCD; 0.1 degree resolution; C or F factory set |
| Type | Intempco DTG53/DTG54 battery-powered LCD digital temperature gauge with Pt1000 Class A RTD |
| Sensor | Pt-1000 Ohm RTD Class A (DIN IEC 60751); all wetted parts stainless steel 316/316L |
| Battery Life | Two 3.6 V AA lithium; minimum 5 years continuous operation |
| Enclosure | IP67 / NEMA 4X waterproof stainless housing |
| Optional Output | Optional 2/3/4-wire RTD retransmission from same process connection |
| Programming | Optional field one/two-point calibration via DTG programming kit |
| Construction | Direct-mount rigid stem or panel flange mounts; probe diameters 1/4 or 3/8 in standard |
| Document | Intempco DTG53 LCD Digital Temperature Gauge datasheet (intempco.com / Yodify CDN) |