WIKA

WIKA CTH6300 Digital Thermometer

SKU · 43292 · CTH6300 Digital Thermometer · Brand: WIKA
Available
Quote on request
No online payment · add lines to RFQ BOM

Handheld digital thermometer for Pt100 and thermocouples; 1- or 2-channel. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
High-accuracy calibration-line thermometer for laboratory and field temperature measurement
Communication
Interface options for documentation / calibration workflows per OEM datasheet
Type
WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes
Channels
1-channel or 2-channel versions
Measuring Range Pt100
About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes
Probe Types
Pt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling
Download datasheet PDF

Fits laboratory and field temperature measurement with a WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes, in 1-channel or 2-channel versions.

Key advantages

  • Pt100 + thermocouple — Dual sensor-family support on CTH6300.
  • 1- or 2-channel — Choose single or dual probe versions.
  • Pt100 ~−200…+600 °C — With suitable Pt100 probes.
  • ZERO/HOLD/MIN-MAX — Field/lab keypad functions; interface options for documentation workflows.

Typical applications

  • Laboratory and field temperature measurement with handheld probes.
  • Dual-channel comparison checks on Pt100 or thermocouple sensors.
  • Calibration workflows that need documentation interface options.

Selection guide

  • Channels — 1-channel or 2-channel versions.
  • Measuring range Pt100 — About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes.
  • Probe types — Pt100 and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling.
  • Display functions — Digital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions.
  • Communication — Interface options for documentation / calibration workflows per OEM datasheet.
  • Related model — CTH63I0 intrinsically safe variant is a related but separate SKU.

Common mistakes

  • Ordering CTH6300 when the area requires the intrinsically safe CTH63I0 sibling — CTH63I0 is Pt100-only and a separate SKU.
  • Leaving channel count blank (1-channel vs 2-channel).
  • Assuming thermocouple support on CTH63I0 — Ex sibling is Pt100-only.
  • Omitting probe type/length when stating the −200…+600 °C Pt100 class range.
  • Skipping interface/documentation needs if the job is a formal calibration workflow.

When to RFQ / what to tell us

  1. 1-channel vs 2-channel, and probe types (Pt100 / thermocouple).
  2. Whether intrinsically safe CTH63I0 is required instead.
  3. Probe lengths, interface needs, quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU43292
BrandWIKA
ModelCTH6300
Product typedigitalhandheldthermometer
TypeWIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes
Channels1-channel or 2-channel versions
Measuring range Pt100About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes
Probe typesPt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling
AccuracyHigh-accuracy calibration-line thermometer for laboratory and field temperature measurement
Display functionsDigital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions
CommunicationInterface options for documentation / calibration workflows per OEM datasheet
ProtectionIndustrial hand-held housing for field and lab use
Related modelCTH63I0 intrinsically safe variant is a related but separate SKU
DocumentWIKA CTH6300/CTH63I0 data sheet + operating instructions (wika.com)

Documents

FAQ

Q: Does CTH6300 support thermocouples? A: Yes — Pt100 and thermocouples. The related CTH63I0 Ex sibling is Pt100-only.

Q: What Pt100 range is listed? A: About −200 to +600 °C with suitable Pt100 probes.

Q: What should I send for a quote? A: Channels, probe types, Ex need (CTH63I0), quantity. Compatible with systems using WIKA CTH6300 — we do not claim authorized-dealer status.

Links

ParameterValue
AccuracyHigh-accuracy calibration-line thermometer for laboratory and field temperature measurement
CommunicationInterface options for documentation / calibration workflows per OEM datasheet
TypeWIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes
Channels1-channel or 2-channel versions
Measuring Range Pt100About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes
Probe TypesPt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling
Display FunctionsDigital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions
ProtectionIndustrial hand-held housing for field and lab use
Related ModelCTH63I0 intrinsically safe variant is a related but separate SKU
DocumentWIKA CTH6300/CTH63I0 data sheet + operating instructions (wika.com)