Image unavailable
Image unavailable
WIKA
WIKA CTH6300 Digital Thermometer
Quote on request
No online payment · add lines to RFQ BOM
Handheld digital thermometer for Pt100 and thermocouples; 1- or 2-channel. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
High-accuracy calibration-line thermometer for laboratory and field temperature measurement
Communication
Interface options for documentation / calibration workflows per OEM datasheet
Type
WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes
Channels
1-channel or 2-channel versions
Measuring Range Pt100
About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes
Probe Types
Pt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling
Fits laboratory and field temperature measurement with a WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes, in 1-channel or 2-channel versions.
Key advantages
- Pt100 + thermocouple — Dual sensor-family support on CTH6300.
- 1- or 2-channel — Choose single or dual probe versions.
- Pt100 ~−200…+600 °C — With suitable Pt100 probes.
- ZERO/HOLD/MIN-MAX — Field/lab keypad functions; interface options for documentation workflows.
Typical applications
- Laboratory and field temperature measurement with handheld probes.
- Dual-channel comparison checks on Pt100 or thermocouple sensors.
- Calibration workflows that need documentation interface options.
Selection guide
- Channels — 1-channel or 2-channel versions.
- Measuring range Pt100 — About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes.
- Probe types — Pt100 and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling.
- Display functions — Digital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions.
- Communication — Interface options for documentation / calibration workflows per OEM datasheet.
- Related model — CTH63I0 intrinsically safe variant is a related but separate SKU.
Common mistakes
- Ordering CTH6300 when the area requires the intrinsically safe CTH63I0 sibling — CTH63I0 is Pt100-only and a separate SKU.
- Leaving channel count blank (1-channel vs 2-channel).
- Assuming thermocouple support on CTH63I0 — Ex sibling is Pt100-only.
- Omitting probe type/length when stating the −200…+600 °C Pt100 class range.
- Skipping interface/documentation needs if the job is a formal calibration workflow.
When to RFQ / what to tell us
- 1-channel vs 2-channel, and probe types (Pt100 / thermocouple).
- Whether intrinsically safe CTH63I0 is required instead.
- Probe lengths, interface needs, quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 43292 |
| Brand | WIKA |
| Model | CTH6300 |
| Product type | digitalhandheldthermometer |
| Type | WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes |
| Channels | 1-channel or 2-channel versions |
| Measuring range Pt100 | About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes |
| Probe types | Pt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling |
| Accuracy | High-accuracy calibration-line thermometer for laboratory and field temperature measurement |
| Display functions | Digital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions |
| Communication | Interface options for documentation / calibration workflows per OEM datasheet |
| Protection | Industrial hand-held housing for field and lab use |
| Related model | CTH63I0 intrinsically safe variant is a related but separate SKU |
| Document | WIKA CTH6300/CTH63I0 data sheet + operating instructions (wika.com) |
Documents
FAQ
Q: Does CTH6300 support thermocouples? A: Yes — Pt100 and thermocouples. The related CTH63I0 Ex sibling is Pt100-only.
Q: What Pt100 range is listed? A: About −200 to +600 °C with suitable Pt100 probes.
Q: What should I send for a quote? A: Channels, probe types, Ex need (CTH63I0), quantity. Compatible with systems using WIKA CTH6300 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Accuracy | High-accuracy calibration-line thermometer for laboratory and field temperature measurement |
| Communication | Interface options for documentation / calibration workflows per OEM datasheet |
| Type | WIKA CTH6300 digital hand-held thermometer for Pt100 and thermocouple probes |
| Channels | 1-channel or 2-channel versions |
| Measuring Range Pt100 | About −200 to +600 °C (−328 to +1112 °F) with suitable Pt100 probes |
| Probe Types | Pt100 resistance thermometers and thermocouples (CTH6300); related CTH63I0 Ex version is Pt100-only sibling |
| Display Functions | Digital °C readout with ZERO/HOLD/MIN-MAX and related keypad functions |
| Protection | Industrial hand-held housing for field and lab use |
| Related Model | CTH63I0 intrinsically safe variant is a related but separate SKU |
| Document | WIKA CTH6300/CTH63I0 data sheet + operating instructions (wika.com) |