E+H Memosens COS81E Optical Oxygen Sensor

SKU · 49379 · E+H Memosens COS81E Digital Optical Oxygen Sensor
Available
Quote on request
No online payment · add lines to RFQ BOM

COS81E: hygienic optical DO, Memosens 2.0, 0.004–30 mg/l. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
±1% of reading or ±8 ppb, whichever is greater
Download datasheet PDF

Digital optical dissolved-oxygen sensor for life-sciences and food hygiene — Memosens 2.0, luminescence quenching, 0.004–30 mg/l range, and CIP/SIP-ready stainless design with EHEDG / ASME BPE alignment.

Key advantages

  • Hygienic optical DO — Designed to EHEDG and ASME BPE; USP Class VI / FDA material path per OEM page.
  • Memosens 2.0 — Inductive digital head; precalibrate in the lab and hot-swap without polarization wait.
  • Stable optics — Reference LED compensates measuring-LED ageing through CIP/SIP and autoclave cycles.
  • Wide range — 0.004–30 mg/l; 0.05–330 %SAT; 0.1–700 hPa; process to 13 bar abs.
  • Ex / inertization ready — International Ex approvals (ATEX, IECEx, and others listed by OEM) for ≥2% vol O₂ monitoring in hazardous atmospheres.

Typical applications

  • Oxygen control in pharmaceutical and biotech fermenters.
  • Food and beverage quality control under hygienic rules.
  • Drinking-water production DO monitoring.
  • Inertization processes in classified areas.

Selection guide

  • Shaft length — 120 / 160 / 220 / 320 / 420 mm options.
  • Spot geometry — C-shape vs U-shape temperature envelopes (0–60 / 80 °C process).
  • Materials — Spot cap in SS 316L, titanium, or Hastelloy; confirm seal FDA vs Ex variants.
  • Transmitter — Pair with Liquiline / Memosens-capable transmitters for the digital head.

Common mistakes

  • Ordering Ex seals when FDA food-contact seals are mandatory — OEM notes Ex process seals are not FDA-compliant.
  • Expecting amperometric membrane service — COS81E is optical; maintenance is spot-cap exchange + calibration.
  • Ignoring sterilization limits — max 140 °C at 6 bar for ≤45 min per OEM.
  • Mixing COS81E with legacy COS81D spares without checking Memosens 2.0 compatibility.

When to RFQ / what to tell us

  1. Shaft length, spot shape/material, Ex vs hygienic seal path, transmitter.
  2. Quantity and ship-to country.

Request a Quote · Get selection help

Specs

SpecValue
SKU49379
BrandEndress+Hauser
ModelMemosens COS81E
Product typeDigital optical dissolved oxygen sensor
Measuring principleLuminescence quenching
Measuring range0.004–30 mg/l; 0.05–330 %SAT; 0.1–700 hPa
Process temperature0–60 °C (C-shape) / 0–80 °C (U-shape); SIP max 140 °C @ 6 bar ≤45 min
Process pressure0.02–13 bar abs (0–190 psi)
ConnectionPg 13.5; Memosens 2.0 inductive digital head
ShaftØ12 mm; lengths 120–420 mm
Temp sensorPt1000
Ingress protectionIP68 / IP69
Hygiene (OEM)EHEDG, ASME BPE, USP VI / FDA material path
Accuracy (seed/OEM class)±1% of reading or ±8 ppb, whichever greater (manufacturerSpecs)

Documents

FAQ

Q: Optical or amperometric? A: COS81E is optical (luminescence quenching) with a replaceable spot cap — no electrolyte membrane.

Q: Can I calibrate offline? A: Yes — Memosens lets you precalibrate and swap into the process without polarization delay.

Q: What should I send for a quote? A: Length, spot/seal options, Ex needs, transmitter, quantity, ship-to.

Links

ParameterValue
Accuracy±1% of reading or ±8 ppb, whichever is greater