Fluke

Fluke 116/62 MAX+ Technician Combo Kit

SKU · 32837 · 116/62 MAX+ Kit · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

Fluke 116/62 MAX+ kit: HVAC True-RMS DMM with µA flame sensor + IR −30…650 °C dual laser. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
116: True-RMS V/A; temperature −40 to 400 °C with 80BK-A; µA flame-sensor; resistance/continuity/frequency/capacitance; 10 A direct (20 A overload 30 s). 62 MAX+: IR −30 to 650 °C, D:S 12:1, dual lasers
Accuracy
116: per Fluke 116 technical data sheet (True-RMS). 62 MAX+: up to ±1.0 °C or ±1.0% of reading
Output
None (handheld DMM + IR; Min/Max/Average recording on 116)
Supply
Battery powered per component OEM sheets
Protection
62 MAX+: IP54; 116 handheld DMM (see 116 TD)
Ambient temperature
Per Fluke 116 and 62 MAX+ datasheets
Download datasheet PDF

Fits HVAC technicians who need a True-RMS DMM with microamp flame-sensor range and built-in temperature plus a dual-laser 62 MAX+ IR thermometer in one combo kit.

Key advantages

  • HVAC True-RMS DMM — Fluke 116 with µA flame-sensor range, temperature −40 to 400 °C (80BK-A), True-RMS V/A.
  • 62 MAX+ IR — −30 to 650 °C, D:S 12:1, dual lasers for non-contact surface checks.
  • Recording — Min/Max/Average on 116; large white LED backlight.
  • CAT III 600 V — Safety listing on 116 for commercial HVAC measurement locations.

Typical applications

  • Furnace / flame-rod microamp checks on the 116 µA range.
  • HVAC voltage, continuity, capacitance, and contact temperature (−40 to 400 °C with 80BK-A).
  • Non-contact surface temperature with 62 MAX+ (−30 to 650 °C, D:S 12:1, dual lasers).
  • Residential and light-commercial HVAC truck kits.

Selection guide

  • Lock µA flame-sensor and contact temperature need — those are 116 strengths vs a generic electrician DMM.
  • 62 MAX+ is IR only — emissivity and spot size (D:S 12:1) must fit the target.
  • Safety listed CAT III 600 V on 116 — confirm category vs the measurement location.
  • State ToolPak magnetic hanger need, quantity, and ship-to.

Common mistakes

  • Buying a generic electrician DMM when µA flame-sensor and contact temperature are the pain points — those are 116 strengths.
  • Ignoring IR emissivity and D:S 12:1 spot size on 62 MAX+.
  • Mismatching CAT III 600 V on 116 to the measurement location.
  • Skipping ToolPak magnetic hanger need on the RFQ.

When to RFQ / what to tell us

  1. µA flame-sensor and contact temperature need yes/no; IR span/D:S fit.
  2. CAT location and ToolPak magnetic hanger yes/no.
  3. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU32837
BrandFluke
Model116/62 MAX+ Kit
Product typetest_kit
Product nameFluke 116/62 MAX+ Technician's Combo Kit
Measuring Range116: True-RMS V/A; temperature −40 to 400 °C with 80BK-A; µA flame-sensor; resistance/continuity/frequency/capacitance; 10 A direct (20 A overload 30 s). 62 MAX+: IR −30 to 650 °C, D:S 12:1, dual lasers
Accuracy116: per Fluke 116 technical data sheet (True-RMS). 62 MAX+: up to ±1.0 °C or ±1.0% of reading
Output SignalNone (handheld DMM + IR; Min/Max/Average recording on 116)
Supply VoltageBattery powered per component OEM sheets
Ip Rating62 MAX+: IP54; 116 handheld DMM (see 116 TD)
Ambient TemperaturePer Fluke 116 and 62 MAX+ datasheets
Sensor TypeHVAC digital multimeter + infrared thermometer combo
Display116 large white LED backlight; 62 MAX+ backlit IR display
ApprovalsCAT III 600 V (116); CE
MountingHandheld; optional ToolPak magnetic hanger for 116

Documents

FAQ

Q: Why 116 instead of a general electrician DMM? A: 116 adds HVAC-oriented µA flame-sensor range and temperature with 80BK-A, plus True-RMS V/A and Min/Max/Average recording.

Q: What IR range is included? A: 62 MAX+: −30 to 650 °C, D:S 12:1, dual lasers; accuracy up to ±1.0 °C or ±1.0% of reading per OEM family datasheet.

Q: What should I send for a quote? A: µA/temp vs IR emphasis, CAT need, hanger yes/no, quantity, ship-to. Compatible with systems using Fluke 116/62 MAX+ — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range116: True-RMS V/A; temperature −40 to 400 °C with 80BK-A; µA flame-sensor; resistance/continuity/frequency/capacitance; 10 A direct (20 A overload 30 s). 62 MAX+: IR −30 to 650 °C, D:S 12:1, dual lasers
Accuracy116: per Fluke 116 technical data sheet (True-RMS). 62 MAX+: up to ±1.0 °C or ±1.0% of reading
OutputNone (handheld DMM + IR; Min/Max/Average recording on 116)
SupplyBattery powered per component OEM sheets
Protection62 MAX+: IP54; 116 handheld DMM (see 116 TD)
Ambient temperaturePer Fluke 116 and 62 MAX+ datasheets
Display116 large white LED backlight; 62 MAX+ backlit IR display
ApprovalsCAT III 600 V (116); CE
MountingHandheld; optional ToolPak magnetic hanger for 116
Sensor typeHVAC digital multimeter + infrared thermometer combo
NotesTechnician combo kit. Specs from Fluke 116 technical data + 62 MAX family datasheet + kit product page.