Fluke 80K-40 HV probe: 0…±40 kV DC/peak AC, 1000:1, 1000 MΩ, meter Zin 10 MΩ, CAT I only. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0 kV to ±40 kV DC or peak AC; 28 kV rms AC (energy-limited / Overvoltage Category I circuits only)
Accuracy
DC: 0–20 kV and 35–40 kV ±2%; 20–35 kV ±1% @ 20–30 °C (add 1% outside). AC: ±5% at 60 Hz. Requires meter Zin 10 MΩ ±1%
Output
1000:1 divider into host DMM/voltmeter (banana plug)
Supply
Passive probe (no power supply)
Protection
Not IP-rated; molded plastic body / Type B probe per IEC 61010-031
Ambient temperature
Operating 0 to 50 °C; storage −20 to +60 °C; RH 80% @ 30 °C / 50% @ 40 °C
Download datasheet PDF

Fits energy-limited high-voltage measurements when you need a passive 1000:1 divider probe to ±40 kV DC or peak AC into a 10 MΩ DMM — Category I circuits only, not power distribution.

Key advantages

  • ±40 kV class — 0…±40 kV DC or peak AC; 28 kV rms AC on energy-limited / Overvoltage Category I circuits only.
  • 1000:1 divider — Input resistance 1000 MΩ; requires meter Zin 10 MΩ ±1%.
  • Published accuracy — DC ±1% to ±2% by range at 20–30 °C; AC ±5% at 60 Hz.
  • IEC 61010-031 Type B — Pollution Degree 2; CAT I only — not for power distribution.

Typical applications

  • Energy-limited / Overvoltage Category I high-voltage DC or peak AC checks to ±40 kV.
  • Lab and equipment HV points where a 1000:1 banana-plug divider feeds a 10 MΩ DMM.
  • AC rms limited to 28 kV on energy-limited circuits per OEM datasheet.

Selection guide

  • CAT I energy-limited only — not for power distribution buses or CAT III/IV work.
  • Host meter must be 10 MΩ ±1% for stated accuracy.
  • Choose 80K-40 (±40 kV) vs 80K-15 (±15 kV) by working voltage; derate above 2000 m altitude.
  • State host DMM model, max voltage, quantity, and ship-to.

Common mistakes

  • Using on power distribution buses or CAT III/IV work — CAT I energy-limited only.
  • Pairing with a meter that is not 10 MΩ ±1% — stated accuracy requires that Zin.
  • Ignoring altitude derate above 2000 m (40→28 kV peak).
  • Ordering 80K-15 when working voltage needs the ±40 kV class.

When to RFQ / what to tell us

  1. Max voltage (DC/peak AC / rms AC) and CAT I energy-limited confirmation.
  2. Host DMM model and Zin (must be 10 MΩ ±1%).
  3. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU32843
BrandFluke
Model80K-40 High Voltage Probe
Product typehighvoltageprobe
Product nameFluke 80K-40 High Voltage Probe
Measuring Range0 kV to ±40 kV DC or peak AC; 28 kV rms AC (energy-limited / Overvoltage Category I circuits only)
AccuracyDC: 0–20 kV and 35–40 kV ±2%; 20–35 kV ±1% @ 20–30 °C (add 1% outside). AC: ±5% at 60 Hz. Requires meter Zin 10 MΩ ±1%
Output Signal1000:1 divider into host DMM/voltmeter (banana plug)
Supply VoltagePassive probe (no power supply)
Ip RatingNot IP-rated; molded plastic body / Type B probe per IEC 61010-031
Ambient TemperatureOperating 0 to 50 °C; storage −20 to +60 °C; RH 80% @ 30 °C / 50% @ 40 °C
Sensor TypeResistive high-voltage divider probe
Division Ratio1000:1
Input Resistance1000 MΩ
Required Meter Impedance10 MΩ ±1%
Safety RatingIEC 61010-031 Type B, Pollution Degree 2; CAT I energy-limited circuits only — NOT for power distribution
Altitude2000 m nominal; 2000–5000 m derate working voltage 40→28 kV peak
ApprovalsIEC 61010-031

Documents

FAQ

Q: What voltage can it measure? A: 0 kV to ±40 kV DC or peak AC; 28 kV rms AC — energy-limited / Overvoltage Category I only.

Q: What meter impedance is required? A: 10 MΩ ±1%. Divider is 1000:1 with 1000 MΩ input resistance.

Q: What should I send for a quote? A: Max voltage, host DMM Zin/model, CAT I confirmation, quantity, ship-to. Compatible with systems using Fluke 80K-40 — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range0 kV to ±40 kV DC or peak AC; 28 kV rms AC (energy-limited / Overvoltage Category I circuits only)
AccuracyDC: 0–20 kV and 35–40 kV ±2%; 20–35 kV ±1% @ 20–30 °C (add 1% outside). AC: ±5% at 60 Hz. Requires meter Zin 10 MΩ ±1%
Output1000:1 divider into host DMM/voltmeter (banana plug)
SupplyPassive probe (no power supply)
ProtectionNot IP-rated; molded plastic body / Type B probe per IEC 61010-031
Ambient temperatureOperating 0 to 50 °C; storage −20 to +60 °C; RH 80% @ 30 °C / 50% @ 40 °C
ApprovalsIEC 61010-031
Sensor typeResistive high-voltage divider probe
NotesOEM Fluke 80K-40/80K-6 instruction sheet Rev.10. No Instrumart.
Division Ratio1000:1
Input Resistance1000 MΩ
Required Meter Impedance10 MΩ ±1%
Safety RatingIEC 61010-031 Type B, Pollution Degree 2; CAT I energy-limited circuits only — NOT for power distribution
Altitude2000 m nominal; 2000–5000 m derate working voltage 40→28 kV peak