Fluke 80K-15 High Voltage Probe
Fluke 80K-15 HV probe: 0…±15 kV DC/peak AC, 1000:1, 1000 MΩ, meter Zin 10 MΩ, CAT I. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits energy-limited high-voltage checks such as electrostatic air cleaners when you need a passive 1000:1 probe to ±15 kV DC or peak AC into a 10 MΩ DMM — Category I only.
Key advantages
- ±15 kV class — 0…±15 kV DC or peak AC; 10 kV rms AC on energy-limited / Overvoltage Category I circuits.
- 1000:1 divider — Input resistance 1000 MΩ; requires meter Zin 10 MΩ ±1%.
- Published accuracy — DC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C).
- Compact probe — 36 cm × 7.5 cm; 204 g; P/N 618113; IEC 61010-031 Type B, CAT I.
Typical applications
- Electrostatic air cleaner and similar energy-limited HV points to ±15 kV.
- Category I circuits where 10 kV rms AC is the AC limit per OEM datasheet.
- Banana-plug 1000:1 feed into a standard 10 MΩ DMM/voltmeter.
Selection guide
- CAT I only with transient overvoltage limited to 60 kV peak — not for power distribution.
- Host meter Zin must be 10 MΩ ±1%.
- Use 80K-15 for ±15 kV class; step up to 80K-40 if working voltage needs ±40 kV.
- State host DMM, max voltage, quantity, and ship-to.
Common mistakes
- Using on power distribution — CAT I only; transient overvoltage limited to 60 kV peak.
- Pairing with a meter that is not 10 MΩ ±1%.
- Ordering 80K-15 when working voltage needs ±40 kV — use 80K-40 instead.
- Expecting a powered probe — this is a passive resistive divider.
When to RFQ / what to tell us
- Max voltage and host DMM Zin/model (10 MΩ ±1%).
- Confirmation of CAT I / energy-limited duty.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 32844 |
| Brand | Fluke |
| Model | 80K-15 High Voltage Probe |
| Product type | highvoltageprobe |
| Product name | Fluke 80K-15 High Voltage Probe |
| Measuring Range | 0 kV to ±15 kV DC or peak AC; 10 kV rms AC (energy-limited / Overvoltage Category I; e.g. electrostatic air cleaners) |
| Accuracy | DC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C). Requires meter Zin 10 MΩ ±1% |
| Output Signal | 1000:1 divider into host DMM/voltmeter |
| Supply Voltage | Passive probe (no power supply) |
| Ip Rating | Not IP-rated; Type B probe per IEC 61010-031 |
| Ambient Temperature | Operating 0 to 50 °C; storage −20 to +60 °C |
| Sensor Type | Resistive high-voltage divider probe (electronic air cleaner probe) |
| Division Ratio | 1000:1 |
| Input Resistance | 1000 MΩ |
| Required Meter Impedance | 10 MΩ ±1% |
| Dimensions | 36 cm × 7.5 cm (14 in × 3 in) |
| Weight | 204 g (7.2 oz) |
| Safety Rating | IEC 61010-031 Type B, Pollution Degree 2; transient overvoltage limited to 60 kV peak; CAT I only |
| Part Number | 618113 |
| Approvals | IEC 61010-031 |
Documents
FAQ
Q: 80K-15 vs 80K-40? A: 80K-15: 0…±15 kV DC/peak AC (10 kV rms AC). 80K-40: 0…±40 kV DC/peak AC (28 kV rms AC). Both 1000:1, CAT I, 10 MΩ meter Zin.
Q: Is it powered? A: No — passive resistive divider probe.
Q: What should I send for a quote? A: Max voltage, host DMM Zin/model, quantity, ship-to. Compatible with systems using Fluke 80K-15 — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | 0 kV to ±15 kV DC or peak AC; 10 kV rms AC (energy-limited / Overvoltage Category I; e.g. electrostatic air cleaners) |
| Accuracy | DC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C). Requires meter Zin 10 MΩ ±1% |
| Output | 1000:1 divider into host DMM/voltmeter |
| Supply | Passive probe (no power supply) |
| Protection | Not IP-rated; Type B probe per IEC 61010-031 |
| Ambient temperature | Operating 0 to 50 °C; storage −20 to +60 °C |
| Approvals | IEC 61010-031 |
| Sensor type | Resistive high-voltage divider probe (electronic air cleaner probe) |
| Notes | OEM Fluke 80K-15 instruction sheet. No Instrumart. |
| Division Ratio | 1000:1 |
| Input Resistance | 1000 MΩ |
| Required Meter Impedance | 10 MΩ ±1% |
| Dimensions | 36 cm × 7.5 cm (14 in × 3 in) |
| Weight | 204 g (7.2 oz) |
| Safety Rating | IEC 61010-031 Type B, Pollution Degree 2; transient overvoltage limited to 60 kV peak; CAT I only |
| Part Number | 618113 |