Fluke

Fluke 80K-15 High Voltage Probe

SKU · 32844 · 80K-15 High Voltage Probe · Brand: Fluke
Available
Quote on request
No online payment · add lines to RFQ BOM

Fluke 80K-15 HV probe: 0…±15 kV DC/peak AC, 1000:1, 1000 MΩ, meter Zin 10 MΩ, CAT I. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0 kV to ±15 kV DC or peak AC; 10 kV rms AC (energy-limited / Overvoltage Category I; e.g. electrostatic air cleaners)
Accuracy
DC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C). Requires meter Zin 10 MΩ ±1%
Output
1000:1 divider into host DMM/voltmeter
Supply
Passive probe (no power supply)
Protection
Not IP-rated; Type B probe per IEC 61010-031
Ambient temperature
Operating 0 to 50 °C; storage −20 to +60 °C
Download datasheet PDF

Fits energy-limited high-voltage checks such as electrostatic air cleaners when you need a passive 1000:1 probe to ±15 kV DC or peak AC into a 10 MΩ DMM — Category I only.

Key advantages

  • ±15 kV class — 0…±15 kV DC or peak AC; 10 kV rms AC on energy-limited / Overvoltage Category I circuits.
  • 1000:1 divider — Input resistance 1000 MΩ; requires meter Zin 10 MΩ ±1%.
  • Published accuracy — DC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C).
  • Compact probe — 36 cm × 7.5 cm; 204 g; P/N 618113; IEC 61010-031 Type B, CAT I.

Typical applications

  • Electrostatic air cleaner and similar energy-limited HV points to ±15 kV.
  • Category I circuits where 10 kV rms AC is the AC limit per OEM datasheet.
  • Banana-plug 1000:1 feed into a standard 10 MΩ DMM/voltmeter.

Selection guide

  • CAT I only with transient overvoltage limited to 60 kV peak — not for power distribution.
  • Host meter Zin must be 10 MΩ ±1%.
  • Use 80K-15 for ±15 kV class; step up to 80K-40 if working voltage needs ±40 kV.
  • State host DMM, max voltage, quantity, and ship-to.

Common mistakes

  • Using on power distribution — CAT I only; transient overvoltage limited to 60 kV peak.
  • Pairing with a meter that is not 10 MΩ ±1%.
  • Ordering 80K-15 when working voltage needs ±40 kV — use 80K-40 instead.
  • Expecting a powered probe — this is a passive resistive divider.

When to RFQ / what to tell us

  1. Max voltage and host DMM Zin/model (10 MΩ ±1%).
  2. Confirmation of CAT I / energy-limited duty.
  3. Quantity and ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU32844
BrandFluke
Model80K-15 High Voltage Probe
Product typehighvoltageprobe
Product nameFluke 80K-15 High Voltage Probe
Measuring Range0 kV to ±15 kV DC or peak AC; 10 kV rms AC (energy-limited / Overvoltage Category I; e.g. electrostatic air cleaners)
AccuracyDC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C). Requires meter Zin 10 MΩ ±1%
Output Signal1000:1 divider into host DMM/voltmeter
Supply VoltagePassive probe (no power supply)
Ip RatingNot IP-rated; Type B probe per IEC 61010-031
Ambient TemperatureOperating 0 to 50 °C; storage −20 to +60 °C
Sensor TypeResistive high-voltage divider probe (electronic air cleaner probe)
Division Ratio1000:1
Input Resistance1000 MΩ
Required Meter Impedance10 MΩ ±1%
Dimensions36 cm × 7.5 cm (14 in × 3 in)
Weight204 g (7.2 oz)
Safety RatingIEC 61010-031 Type B, Pollution Degree 2; transient overvoltage limited to 60 kV peak; CAT I only
Part Number618113
ApprovalsIEC 61010-031

Documents

FAQ

Q: 80K-15 vs 80K-40? A: 80K-15: 0…±15 kV DC/peak AC (10 kV rms AC). 80K-40: 0…±40 kV DC/peak AC (28 kV rms AC). Both 1000:1, CAT I, 10 MΩ meter Zin.

Q: Is it powered? A: No — passive resistive divider probe.

Q: What should I send for a quote? A: Max voltage, host DMM Zin/model, quantity, ship-to. Compatible with systems using Fluke 80K-15 — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range0 kV to ±15 kV DC or peak AC; 10 kV rms AC (energy-limited / Overvoltage Category I; e.g. electrostatic air cleaners)
AccuracyDC ±2% (10–45 °C); AC ±5% @ 60 Hz (20–30 °C). Requires meter Zin 10 MΩ ±1%
Output1000:1 divider into host DMM/voltmeter
SupplyPassive probe (no power supply)
ProtectionNot IP-rated; Type B probe per IEC 61010-031
Ambient temperatureOperating 0 to 50 °C; storage −20 to +60 °C
ApprovalsIEC 61010-031
Sensor typeResistive high-voltage divider probe (electronic air cleaner probe)
NotesOEM Fluke 80K-15 instruction sheet. No Instrumart.
Division Ratio1000:1
Input Resistance1000 MΩ
Required Meter Impedance10 MΩ ±1%
Dimensions36 cm × 7.5 cm (14 in × 3 in)
Weight204 g (7.2 oz)
Safety RatingIEC 61010-031 Type B, Pollution Degree 2; transient overvoltage limited to 60 kV peak; CAT I only
Part Number618113