Image unavailable
Image unavailable
Fluke
Fluke 1587/MDT FC Motor & Drive Troubleshooting Kit
Quote on request
No online payment · add lines to RFQ BOM
1587 FC insulation + i400 + 9040 phase rotation kit. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Measuring range
1587 FC insulation 0.01 MΩ–2 GΩ; DMM functions per 1587 FC TD. Kit adds i400 clamp 1–400 A AC and 9040 phase rotation
Accuracy
Insulation accuracies per Fluke 1587 FC/1577 Technical Data (e.g. 250/500/1000 V bands ±(1.5%+5) typical ranges)
Output
Digital 6000-count display; Fluke Connect PI/DAR graphs; VFD low-pass filter
Supply
Battery powered (meter); see 1587 FC UM for battery life (~1000 h meter use)
Electrical connection
Test leads, remote probe, alligator clips; i400 jaw Ø32 mm; 9040 three-phase leads
Approvals
CAT III 1000 V; CAT IV 600 V; CE
Fits motor and drive insulation troubleshooting where you need a Fluke 1587/MDT FC kit combining a 1587 FC insulation multimeter (0.01 MΩ–2 GΩ), i400 AC clamp, and 9040 phase rotation indicator with Fluke Connect.
Key advantages
- Insulation — 1587 FC 0.01 MΩ–2 GΩ; VFD low-pass filter; PI/DAR via Fluke Connect
- Clamp — i400 1–400 A AC
- Phase — 9040 phase rotation indicator
- Display — 6000-count; digital insulation workflows
- Kit — Advanced motor & drive troubleshooting set
Typical applications
- Motor insulation and PI/DAR.
- VFD output measurements with filter.
- Phase sequence before motor connect.
Selection guide
- Kit vs meter-only
- Fluke Connect — PI/DAR graphs
- Clamp range — To 400 A
- Test voltages — 250/500/1000 V bands
Common mistakes
- Insulation testing without isolation.
- Ignoring VFD filter when needed.
- Wrong phase sequence energization.
When to RFQ / what to tell us
- Kit completeness; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 32845 |
| Brand | Fluke |
| Model | 1587/MDT FC Kit |
| Product type | Insulation / Motor Test Kit |
| Measuring range | 1587 FC insulation 0.01 MΩ–2 GΩ; DMM functions per 1587 FC TD. Kit adds i400 clamp 1–400 A AC and 9040 phase rotation |
| Accuracy | Insulation accuracies per Fluke 1587 FC/1577 Technical Data (e.g. 250/500/1000 V bands ±(1.5%+5) typical ranges) |
| Output signal | Digital 6000-count display; Fluke Connect PI/DAR graphs; VFD low-pass filter |
| Supply | Battery powered (meter); see 1587 FC UM for battery life (~1000 h meter use) |
| Sensor type | Insulation multimeter + AC current clamp + phase rotation indicator kit |
Documents
FAQ
Q: What's in the kit? A: 1587 FC insulation multimeter, i400 clamp, and 9040 phase rotation.
Q: Insulation range? A: 0.01 MΩ to 2 GΩ class.
Q: What should I send for a quote? A: Quantity and ship-to.
Links
| Parameter | Value |
|---|---|
| Measuring range | 1587 FC insulation 0.01 MΩ–2 GΩ; DMM functions per 1587 FC TD. Kit adds i400 clamp 1–400 A AC and 9040 phase rotation |
| Accuracy | Insulation accuracies per Fluke 1587 FC/1577 Technical Data (e.g. 250/500/1000 V bands ±(1.5%+5) typical ranges) |
| Output | Digital 6000-count display; Fluke Connect PI/DAR graphs; VFD low-pass filter |
| Supply | Battery powered (meter); see 1587 FC UM for battery life (~1000 h meter use) |
| Electrical connection | Test leads, remote probe, alligator clips; i400 jaw Ø32 mm; 9040 three-phase leads |
| Approvals | CAT III 1000 V; CAT IV 600 V; CE |
| Mounting | Handheld kit with hard case |
| Sensor type | Insulation multimeter + AC current clamp + phase rotation indicator kit |
| Notes | Kit = 1587 FC + i400 + 9040. Specs from fluke.com kit page + 1587 FC/1577 Technical Data. |