Image unavailable
Image unavailable
Optris
Optris CS LT Infrared Temperature Sensor
Quote on request
No online payment · add lines to RFQ BOM
Optris CS LT: −50…1030 °C; 8–14 µm; 15:1; 14 ms; IP65; 5–30 VDC. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Protection
IP65
Ambient temperature
-20 °C … 80 °C
Temperature Range
-50 °C … 1030 °C (scalable via software)
Spectral Range
8 – 14 μm
Optical Resolution
15:1 (90% energy)
System Accuracy
±1.5% or ±1.5 °C (at 23±5 °C ambient)
Fits compact non-contact temperature sensing where you need an Optris CS LT—IR sensor spanning −50…1030 °C (scalable), 8–14 µm, 15:1 optics, 14 ms response (adjustable), IP65 housing, and 0–5/10 V or Type K outputs on 5–30 V DC power.
Key advantages
- Range — −50…1030 °C scalable
- Spectral — 8–14 µm
- Optics — 15:1 (90% energy)
- Response — 14 ms (adjustable to 999 s)
- Power — 5–30 V DC; about 58 g
Typical applications
- OEM machine IR.
- Packaging heat checks.
- Compact process spots.
Selection guide
- Output type
- Spot size at distance
- Ambient −20…80 °C
Common mistakes
- Spot larger than target.
- Wrong emissivity.
- Overlooking ambient limit.
When to RFQ / what to tell us
- Output/options.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 44835 |
| Brand | Optris |
| Model | CS LT |
| Product type | Infrared Temperature Sensor |
| Temperature range | -50 °C … 1030 °C (scalable via software) |
| Spectral range | 8 – 14 μm |
| Optical resolution | 15:1 (90% energy) |
| System accuracy | ±1.5% or ±1.5 °C (at 23±5 °C ambient) |
| Response time | 14 ms (adjustable up to 999 s) |
| IP rating | IP65 |
| Outputs | 0–5 V / 0–10 V scalable; Type K thermocouple; open-collector alarm; digital/USB optional |
| Power supply | 5 – 30 V DC |
Documents
FAQ
Q: Range? A: −50…1030 °C scalable.
Q: Optics? A: 15:1.
Q: What should I send for a quote? A: Output/options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Protection | IP65 |
| Ambient temperature | -20 °C … 80 °C |
| Temperature Range | -50 °C … 1030 °C (scalable via software) |
| Spectral Range | 8 – 14 μm |
| Optical Resolution | 15:1 (90% energy) |
| System Accuracy | ±1.5% or ±1.5 °C (at 23±5 °C ambient) |
| Response Time | 14 ms (adjustable up to 999 s) |
| Outputs | 0–5 V / 0–10 V scalable; Type K thermocouple; open-collector alarm; digital/USB optional |
| Power Supply | 5 – 30 V DC |
| Weight | 58 g |