Optris

Optris CTlaser 1M / 2M Infrared Temperature Sensor

SKU · 45093 · CTlaser 1M / 2M · Brand: Optris
Available
Quote on request
No online payment · add lines to RFQ BOM

Optris CTlaser 1M/2M: short-wave; to 2200 °C; 150:1/300:1; dual laser; 1 ms. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Temperature Ranges
1ML 485…1050 °C; 1MH 650…1800 °C; 1MH1 800…2200 °C; 2ML 250…800 °C; 2MH 385…1600 °C; 2MH1 490…2000 °C
Spectral Ranges
1.0 μm (CTlaser 1M) / 1.6 μm (CTlaser 2M)
Optical Resolution
150:1 (1ML/2ML); 300:1 (1MH/1MH1/2MH/2MH1)
System Accuracy
±(0.3% of reading + 2 °C) at 23±5 °C (ε=1, 1 s)
Repeatability
±(0.1% of reading + 1 °C)
Exposure Time
1 ms (90%)
Download datasheet PDF

Fits aimed high-temperature metal IR where you need an Optris CTlaser 1M or 2M—short-wave pyrometer (1.0 / 1.6 µm) with dual laser aiming, optics to 300:1, 1 ms exposure, and spans up to about 2200 °C depending on sub-range.

Key advantages

  • Spectral — 1.0 µm (1M) / 1.6 µm (2M)
  • Optics — 150:1 or 300:1
  • Aiming — Double laser marks real spot
  • Speed — 1 ms (90%)
  • Accuracy — ±(0.3% of reading + 2 °C) class

Typical applications

  • Hot metal with laser aim.
  • Furnace spots.
  • High-temp OEM lines.

Selection guide

  • 1M vs 2M
  • Sub-range / optic
  • Digital interface

Common mistakes

  • Laser ON above ~50 °C ambient.
  • Wrong wavelength for alloy.
  • Spot too large.

When to RFQ / what to tell us

  1. Model/range/output.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU45093
BrandOptris
ModelCTlaser 1M / 2M
Product typeInfrared Temperature Sensor
Temperature ranges1ML 485…1050 °C; 1MH 650…1800 °C; 1MH1 800…2200 °C; 2ML 250…800 °C; 2MH 385…1600 °C; 2MH1 490…2000 °C
Spectral ranges1.0 μm (CTlaser 1M) / 1.6 μm (CTlaser 2M)
Optical resolution150:1 (1ML/2ML); 300:1 (1MH/1MH1/2MH/2MH1)
System accuracy±(0.3% of reading + 2 °C) at 23±5 °C (ε=1, 1 s)
Repeatability±(0.1% of reading + 1 °C)
Exposure time1 ms (90%)
AimingDouble laser aiming marks real spot location at any distance (635 nm, 1 mW)
Outputs0/4–20 mA, 0–5/10 V, thermocouple J/K; optional digital (USB/RS485/Ethernet/…)

Documents

FAQ

Q: Optics? A: 150:1 or 300:1.

Q: Aiming? A: Double laser.

Q: What should I send for a quote? A: Model/range/output, quantity, ship-to.

Links

ParameterValue
Temperature Ranges1ML 485…1050 °C; 1MH 650…1800 °C; 1MH1 800…2200 °C; 2ML 250…800 °C; 2MH 385…1600 °C; 2MH1 490…2000 °C
Spectral Ranges1.0 μm (CTlaser 1M) / 1.6 μm (CTlaser 2M)
Optical Resolution150:1 (1ML/2ML); 300:1 (1MH/1MH1/2MH/2MH1)
System Accuracy±(0.3% of reading + 2 °C) at 23±5 °C (ε=1, 1 s)
Repeatability±(0.1% of reading + 1 °C)
Exposure Time1 ms (90%)
AimingDouble laser aiming marks real spot location at any distance (635 nm, 1 mW)
Outputs0/4–20 mA, 0–5/10 V, thermocouple J/K; optional digital (USB/RS485/Ethernet/…)
Power8–36 V DC
AmbientSensing head/electronics −20…85 °C (laser ON limit 50 °C); IP65
WeightSensing head ~600 g; electronics ~420 g
Softwareoptris Compact Connect
ApplicationMetals, secondary metal processing, ceramics high-temp non-contact measurement