Optris

Optris CT 4M High-Speed IR Sensor

SKU · 48276 · CT 4M Infrared Temperature Sensor · Brand: Optris
Available
Quote on request
No online payment · add lines to RFQ BOM

Optris CT 4M/4ML: 0…500 °C, 90 µs exposure, 2.2–6 µm, IP65 head. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
0 °C … 500 °C (scalable via keys/software)
Accuracy
System accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient
Output
Dual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in
Supply
8–30 VDC or 5 V USB; max ~1.2 W
Ambient temperature
Sensing head and electronics 0–70 °C operating; storage −40–85 °C
Notes
Specs from Optris CT 4ML datasheet EN2020-12-B. No Instrumart.
Download datasheet PDF

Fits fixed non-contact temperature measurement of fast or small targets when you need a compact Ø14×28 mm sensing head with 90 µs exposure (90%), 0…500 °C scalable range, and 2.2–6 µm spectral band.

Key advantages

  • Fast IR response — exposure 90 µs (90%) and response 300 µs (90%) on the CT 4ML line.
  • Compact sensing head — small head for tight machine mounts with separate electronics.
  • Published accuracy — ±(0.3% of reading + 2 °C) on the CT 4M family values used here.
  • Industrial integration — analog / digital options per ordered configuration for PLC use.

Typical applications

  • High-speed process surfaces where contact probes cannot keep up.
  • Small targets on packaging, plastics, or metal lines needing fixed IR.
  • Machine builds that separate the sensing head from the electronics box.

Selection guide

  • Measuring range — 0 °C … 500 °C (scalable via keys/software).
  • Spectral range — 2.2 – 6 µm.
  • Optical resolution — 10:1 (90% energy).
  • Accuracy — System accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient.
  • Repeatability — ±(0.1% of reading + 1 °C).
  • Response — Exposure 90 µs (90%); response 300 µs (90%).
  • NETD — 120 mK.
  • Emissivity — 0.100 – 1.100 adjustable.

Common mistakes

  • Specifying for glass or high-temp metals outside the 2.2–6 µm / 0…500 °C envelope — lock spectral band and span to the target.
  • Ignoring 10:1 optics vs spot size at working distance.
  • Assuming relays are included — dual analog / TC K / alarm / USB are listed; relays are optional.
  • Overlooking head ambient 0–70 °C when mounting near hot process — may need cooling accessories (confirm on RFQ).
  • Confusing exposure 90 µs with response 300 µs (both at 90%).

When to RFQ / what to tell us

  1. Target material/emissivity, temperature span within 0…500 °C, and required spot size vs 10:1 at working distance.
  2. Output (0/4–20 mA, 0–5/10 V, TC K, alarm, optional relays, USB) and supply (8–30 VDC or USB).
  3. Head/electronics ambient, IP65 mounting, quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU48276
BrandOptris
ModelCT 4M Infrared Temperature Sensor
Product typeinfrared_thermometer
Measuring range0 °C … 500 °C (scalable via keys/software)
Spectral range2.2 – 6 µm
Optical resolution10:1 (90% energy)
AccuracySystem accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient
Repeatability±(0.1% of reading + 1 °C)
Response timeExposure 90 µs (90%); response 300 µs (90%)
NETD120 mK
Emissivity0.100 – 1.100 adjustable
Output signalDual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in
Supply voltage8–30 VDC or 5 V USB; max ~1.2 W
Ambient temperatureSensing head and electronics 0–70 °C operating; storage −40–85 °C
Protection ratingIP65 (NEMA-4)
DimensionsHead Ø14 mm × 28 mm; head mass ~40 g; electronics ~420 g

Documents

FAQ

Q: How fast is CT 4M? A: Exposure 90 µs (90%) and response 300 µs (90%) on the CT 4ML published values.

Q: What outputs are available? A: Dual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in.

Q: What should I send for a quote? A: Target material/emissivity, span, spot size, output, ambient, quantity. Compatible with systems using Optris CT 4M / CT 4ML — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring range0 °C … 500 °C (scalable via keys/software)
AccuracySystem accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient
OutputDual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in
Supply8–30 VDC or 5 V USB; max ~1.2 W
Ambient temperatureSensing head and electronics 0–70 °C operating; storage −40–85 °C
NotesSpecs from Optris CT 4ML datasheet EN2020-12-B. No Instrumart.
Spectral Range2.2 – 6 µm
Optical Resolution10:1 (90% energy)
Repeatability±(0.1% of reading + 1 °C)
Response TimeExposure 90 µs (90%); response 300 µs (90%)
Netd120 mK
Emissivity0.100 – 1.100 adjustable
Protection RatingIP65 (NEMA-4)
DimensionsHead Ø14 mm × 28 mm; head mass ~40 g; electronics ~420 g