Key parameters
Fits fixed non-contact temperature measurement of fast or small targets when you need a compact Ø14×28 mm sensing head with 90 µs exposure (90%), 0…500 °C scalable range, and 2.2–6 µm spectral band.
Key advantages
- Fast IR response — exposure 90 µs (90%) and response 300 µs (90%) on the CT 4ML line.
- Compact sensing head — small head for tight machine mounts with separate electronics.
- Published accuracy — ±(0.3% of reading + 2 °C) on the CT 4M family values used here.
- Industrial integration — analog / digital options per ordered configuration for PLC use.
Typical applications
- High-speed process surfaces where contact probes cannot keep up.
- Small targets on packaging, plastics, or metal lines needing fixed IR.
- Machine builds that separate the sensing head from the electronics box.
Selection guide
- Measuring range — 0 °C … 500 °C (scalable via keys/software).
- Spectral range — 2.2 – 6 µm.
- Optical resolution — 10:1 (90% energy).
- Accuracy — System accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient.
- Repeatability — ±(0.1% of reading + 1 °C).
- Response — Exposure 90 µs (90%); response 300 µs (90%).
- NETD — 120 mK.
- Emissivity — 0.100 – 1.100 adjustable.
Common mistakes
- Specifying for glass or high-temp metals outside the 2.2–6 µm / 0…500 °C envelope — lock spectral band and span to the target.
- Ignoring 10:1 optics vs spot size at working distance.
- Assuming relays are included — dual analog / TC K / alarm / USB are listed; relays are optional.
- Overlooking head ambient 0–70 °C when mounting near hot process — may need cooling accessories (confirm on RFQ).
- Confusing exposure 90 µs with response 300 µs (both at 90%).
When to RFQ / what to tell us
- Target material/emissivity, temperature span within 0…500 °C, and required spot size vs 10:1 at working distance.
- Output (0/4–20 mA, 0–5/10 V, TC K, alarm, optional relays, USB) and supply (8–30 VDC or USB).
- Head/electronics ambient, IP65 mounting, quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 48276 |
| Brand | Optris |
| Model | CT 4M Infrared Temperature Sensor |
| Product type | infrared_thermometer |
| Measuring range | 0 °C … 500 °C (scalable via keys/software) |
| Spectral range | 2.2 – 6 µm |
| Optical resolution | 10:1 (90% energy) |
| Accuracy | System accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient |
| Repeatability | ±(0.1% of reading + 1 °C) |
| Response time | Exposure 90 µs (90%); response 300 µs (90%) |
| NETD | 120 mK |
| Emissivity | 0.100 – 1.100 adjustable |
| Output signal | Dual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in |
| Supply voltage | 8–30 VDC or 5 V USB; max ~1.2 W |
| Ambient temperature | Sensing head and electronics 0–70 °C operating; storage −40–85 °C |
| Protection rating | IP65 (NEMA-4) |
| Dimensions | Head Ø14 mm × 28 mm; head mass ~40 g; electronics ~420 g |
Documents
FAQ
Q: How fast is CT 4M? A: Exposure 90 µs (90%) and response 300 µs (90%) on the CT 4ML published values.
Q: What outputs are available? A: Dual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in.
Q: What should I send for a quote? A: Target material/emissivity, span, spot size, output, ambient, quantity. Compatible with systems using Optris CT 4M / CT 4ML — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | 0 °C … 500 °C (scalable via keys/software) |
| Accuracy | System accuracy ±(0.3% of reading + 2 °C) at 23 ±5 °C ambient |
| Output | Dual analog 0/4–20 mA, 0–5/10 V, thermocouple K, alarm; optional relays; USB built-in |
| Supply | 8–30 VDC or 5 V USB; max ~1.2 W |
| Ambient temperature | Sensing head and electronics 0–70 °C operating; storage −40–85 °C |
| Notes | Specs from Optris CT 4ML datasheet EN2020-12-B. No Instrumart. |
| Spectral Range | 2.2 – 6 µm |
| Optical Resolution | 10:1 (90% energy) |
| Repeatability | ±(0.1% of reading + 1 °C) |
| Response Time | Exposure 90 µs (90%); response 300 µs (90%) |
| Netd | 120 mK |
| Emissivity | 0.100 – 1.100 adjustable |
| Protection Rating | IP65 (NEMA-4) |
| Dimensions | Head Ø14 mm × 28 mm; head mass ~40 g; electronics ~420 g |