Image unavailable
Image unavailable
Honeywell
Honeywell FS20X Flame Detector
Quote on request
No online payment · add lines to RFQ BOM
UV/IR multi-spectrum flame detector. Selectable sensitivity to 60 m class; IP66. RFQ + engineer selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Communication
RS-485 ModBus / FireBus II; optional HART plug-in
Approvals
FM Class I Div 1&2; ATEX/IECEx Ex db IIC; SIL 2; EN54-10 option
Field Of View
90° horizontal cone of vision, ±45° from on-axis
Detection Range
>60 m (200 ft) to 0.1 m² (1 sq ft) heptane fire (very high sensitivity)
Sensitivity Settings
Very high (60 m), high (45 m), medium (30 m), low (15 m) — switch selectable
Response Time
3–5 s to 0.1 m² n-Heptane at 30 m; 3–10 s at 60 m
Fits outdoor/process flame detection where you need a Honeywell FS20X UV/IR multi-spectrum detector with selectable sensitivity to 60 m class.
Key advantages
- Multi-spectrum UV/IR — bands UV 185–260 nm; Visible 400–700 nm; Near Band IR 0.7–1.1 µm; Wide Band IR 1.1–3.5 µm
- Range — >60 m (200 ft) to 0.1 m² (1 sq ft) heptane fire (very high sensitivity)
- Selectable sensitivity — Very high (60 m), high (45 m), medium (30 m), low (15 m) — switch selectable
- Outputs — 0–20 mA stepped, source or sink selectable; RS-485 ModBus / FireBus II; optional HART plug-in
- Enclosure — Type 4X, IP66 / NEMA 4; aluminum or 316 SS; −40…+85 °C.
Typical applications
- Hydrocarbon fire detection on process units and loading areas.
- Loops needing 0–20 mA stepped analog plus Modbus/FireBus II.
- Aluminum or 316 SS Type 4X / IP66 installs.
Selection guide
- Sensitivity setting — Very high (60 m), high (45 m), medium (30 m), low (15 m) — switch selectable
- Response — 3–5 s to 0.1 m² n-Heptane at 30 m; 3–10 s at 60 m
- Housing — aluminum vs 316 SS.
- Comms — RS-485 ModBus / FireBus II; optional HART plug-in.
- Supply — 24 Vdc nominal (18–32 Vdc) regulated
Common mistakes
- Leaving sensitivity on Very High near nuisance IR sources without a site assessment.
- Mixing source vs sink 0–20 mA wiring.
- Ignoring FOV (±45° from on-axis) when placing detectors.
When to RFQ / what to tell us
- Fuel, required detection distance, sensitivity setting.
- Housing material; HART yes/no; quantity; ship-to; certifications needed.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 103757 |
| Brand | Honeywell |
| Model | FS20X |
| Product type | Flame Detector |
| Field of view | 90° horizontal cone of vision, ±45° from on-axis |
| Detection range | >60 m (200 ft) to 0.1 m² (1 sq ft) heptane fire (very high sensitivity) |
| Sensitivity settings | Very high (60 m), high (45 m), medium (30 m), low (15 m) — switch selectable |
| Response time | 3–5 s to 0.1 m² n-Heptane at 30 m; 3–10 s at 60 m |
| Spectral bands | UV 185–260 nm; Visible 400–700 nm; Near Band IR 0.7–1.1 µm; Wide Band IR 1.1–3.5 µm |
| Operating voltage | 24 Vdc nominal (18–32 Vdc) regulated |
| Analog output | 0–20 mA stepped, source or sink selectable |
| Communication | RS-485 ModBus / FireBus II; optional HART plug-in |
| Operating temperature | −40 to +85 °C (−40 to +185 °F) |
| Enclosure | Type 4X, IP66 / NEMA 4; aluminum or 316 SS |
| Shipping weight | Aluminum 1.6 kg (3.6 lb); Stainless steel 3.2 kg (7 lb) |
Documents
FAQ
Q: Max published range? A: >60 m (200 ft) to 0.1 m² heptane fire at very high sensitivity.
Q: Temperature? A: −40 to +85 °C operating.
Q: What should I send for a quote? A: Duty, distance, housing, comms, quantity.
Links
| Parameter | Value |
|---|---|
| Communication | RS-485 ModBus / FireBus II; optional HART plug-in |
| Approvals | FM Class I Div 1&2; ATEX/IECEx Ex db IIC; SIL 2; EN54-10 option |
| Field Of View | 90° horizontal cone of vision, ±45° from on-axis |
| Detection Range | >60 m (200 ft) to 0.1 m² (1 sq ft) heptane fire (very high sensitivity) |
| Sensitivity Settings | Very high (60 m), high (45 m), medium (30 m), low (15 m) — switch selectable |
| Response Time | 3–5 s to 0.1 m² n-Heptane at 30 m; 3–10 s at 60 m |
| Spectral Bands | UV 185–260 nm; Visible 400–700 nm; Near Band IR 0.7–1.1 µm; Wide Band IR 1.1–3.5 µm |
| Operating Voltage | 24 Vdc nominal (18–32 Vdc) regulated |
| Analog Output | 0–20 mA stepped, source or sink selectable |
| Operating Temperature | −40 to +85 °C (−40 to +185 °F) |
| Enclosure | Type 4X, IP66 / NEMA 4; aluminum or 316 SS |
| Shipping Weight | Aluminum 1.6 kg (3.6 lb); Stainless steel 3.2 kg (7 lb) |