Key parameters
Accuracy
±0.2% of measured value (with IFC 300)
Approvals
NSF potable water (hard rubber liner); CSA
Principle
Electromagnetic flowmeter for North American water and wastewater
Conductivity
≥1 µS/cm (water ≥20 µS/cm)
Solids Content
Max. 70%
Size Range
1…120 in
Fits North American water and wastewater metering where you need a KROHNE ENVIROMAG 2000 electromagnetic flowmeter with ±0.2% accuracy (with IFC 300), 1–120 in sizes, and NSF potable-water options.
Key advantages
- Accuracy — ±0.2% of measured value (with IFC 300)
- Size — 1…120 in
- Media — Conductivity ≥1 µS/cm (water ≥20 µS/cm); solids to 70%
- Protection — IP66/67; NEMA 4/4X/6; direct burial NEMA 6P option
- I/O / power — 3×4…20 mA, HART, Modbus, FF, Profibus, PROFINET; AC/DC supplies
Typical applications
- Municipal water and wastewater.
- NSF potable-water lined meters.
- Large-diameter magmeter installs to 120 in.
Selection guide
- Size / liner — DN and NSF hard-rubber needs
- Converter — IFC 300 pairing for ±0.2%
- Outputs — HART / Modbus / FF / Profibus / PROFINET
- Install — Direct burial / NEMA options
- Power — 85…250 VAC vs 11…31 VDC
Common mistakes
- Low-conductivity fluids below ≥1 µS/cm.
- Ignoring grounding/virtual reference needs.
- Wrong liner for potable NSF service.
When to RFQ / what to tell us
- Fluid, size, flow, conductivity.
- Liner/outputs/power; quantity; ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 21734 |
| Brand | KROHNE |
| Model | ENVIROMAG 2000 Electromagnetic Flow Meter |
| Product type | Electromagnetic Flow Meter |
| Principle | Electromagnetic flowmeter for North American water and wastewater |
| Accuracy | ±0.2% of measured value (with IFC 300) |
| Conductivity | ≥1 µS/cm (water ≥20 µS/cm) |
| Solids content | Max. 70% |
| Size range | 1…120 in |
| Protection | IP66/67; NEMA 4/4X/6; direct burial NEMA 6P option |
| Approvals | NSF potable water (hard rubber liner); CSA |
| Outputs | 3×4…20 mA, HART, Modbus, FF, Profibus-PA/DP, PROFINET |
| Power | 85…250 VAC, 11…31 VDC, 20.5…26 VAC/DC |
| Features | Wet calibrated; continuous self-diagnostics; virtual reference option |
Documents
FAQ
Q: Accuracy? A: ±0.2% of measured value with IFC 300.
Q: Size range? A: 1…120 in.
Q: What should I send for a quote? A: Size/fluid/outputs, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±0.2% of measured value (with IFC 300) |
| Approvals | NSF potable water (hard rubber liner); CSA |
| Principle | Electromagnetic flowmeter for North American water and wastewater |
| Conductivity | ≥1 µS/cm (water ≥20 µS/cm) |
| Solids Content | Max. 70% |
| Size Range | 1…120 in |
| Protection | IP66/67; NEMA 4/4X/6; direct burial NEMA 6P option |
| Outputs | 3×4…20 mA, HART, Modbus, FF, Profibus-PA/DP, PROFINET |
| Power | 85…250 VAC, 11…31 VDC, 20.5…26 VAC/DC |
| Features | Wet calibrated; continuous self-diagnostics; virtual reference option |