Key parameters

Accuracy
±0.2% of measured value (with IFC 300)
Approvals
NSF potable water (hard rubber liner); CSA
Principle
Electromagnetic flowmeter for North American water and wastewater
Conductivity
≥1 µS/cm (water ≥20 µS/cm)
Solids Content
Max. 70%
Size Range
1…120 in
Download datasheet PDF

Fits North American water and wastewater metering where you need a KROHNE ENVIROMAG 2000 electromagnetic flowmeter with ±0.2% accuracy (with IFC 300), 1–120 in sizes, and NSF potable-water options.

Key advantages

  • Accuracy — ±0.2% of measured value (with IFC 300)
  • Size — 1…120 in
  • Media — Conductivity ≥1 µS/cm (water ≥20 µS/cm); solids to 70%
  • Protection — IP66/67; NEMA 4/4X/6; direct burial NEMA 6P option
  • I/O / power — 3×4…20 mA, HART, Modbus, FF, Profibus, PROFINET; AC/DC supplies

Typical applications

  • Municipal water and wastewater.
  • NSF potable-water lined meters.
  • Large-diameter magmeter installs to 120 in.

Selection guide

  • Size / liner — DN and NSF hard-rubber needs
  • Converter — IFC 300 pairing for ±0.2%
  • Outputs — HART / Modbus / FF / Profibus / PROFINET
  • Install — Direct burial / NEMA options
  • Power — 85…250 VAC vs 11…31 VDC

Common mistakes

  • Low-conductivity fluids below ≥1 µS/cm.
  • Ignoring grounding/virtual reference needs.
  • Wrong liner for potable NSF service.

When to RFQ / what to tell us

  1. Fluid, size, flow, conductivity.
  2. Liner/outputs/power; quantity; ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU21734
BrandKROHNE
ModelENVIROMAG 2000 Electromagnetic Flow Meter
Product typeElectromagnetic Flow Meter
PrincipleElectromagnetic flowmeter for North American water and wastewater
Accuracy±0.2% of measured value (with IFC 300)
Conductivity≥1 µS/cm (water ≥20 µS/cm)
Solids contentMax. 70%
Size range1…120 in
ProtectionIP66/67; NEMA 4/4X/6; direct burial NEMA 6P option
ApprovalsNSF potable water (hard rubber liner); CSA
Outputs3×4…20 mA, HART, Modbus, FF, Profibus-PA/DP, PROFINET
Power85…250 VAC, 11…31 VDC, 20.5…26 VAC/DC
FeaturesWet calibrated; continuous self-diagnostics; virtual reference option

Documents

FAQ

Q: Accuracy? A: ±0.2% of measured value with IFC 300.

Q: Size range? A: 1…120 in.

Q: What should I send for a quote? A: Size/fluid/outputs, quantity, ship-to.

Links

ParameterValue
Accuracy±0.2% of measured value (with IFC 300)
ApprovalsNSF potable water (hard rubber liner); CSA
PrincipleElectromagnetic flowmeter for North American water and wastewater
Conductivity≥1 µS/cm (water ≥20 µS/cm)
Solids ContentMax. 70%
Size Range1…120 in
ProtectionIP66/67; NEMA 4/4X/6; direct burial NEMA 6P option
Outputs3×4…20 mA, HART, Modbus, FF, Profibus-PA/DP, PROFINET
Power85…250 VAC, 11…31 VDC, 20.5…26 VAC/DC
FeaturesWet calibrated; continuous self-diagnostics; virtual reference option