Rosemount

Rosemount 8750W Magnetic Flow Meter

SKU · 40544 · 8750W Magnetic Flow Meter · Brand: Rosemount
Available
Quote on request
No online payment · add lines to RFQ BOM

Rosemount 8750W: water/wastewater magmeter; ±0.5% (±0.2% opt). RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Base accuracy 0.5% of rate standard; optional high accuracy 0.2% of rate (PDS)
Approvals
Drinking water certifications available; agency approvals per PDS ordering table
Product Family
Rosemount 8750W magnetic flow meter system for utility water/wastewater (flanged sensor + field/wall-mount transmitter)
Line Sizes
½ in. to 48 in. (15 mm to 1,200 mm) flanged
Outputs
4–20 mA HART; FOUNDATION Fieldbus; Modbus RS-485; EtherNet/IP; pulse; optional discrete channels
Liner Materials
PTFE, PEX, Neoprene, Polyurethane (process temperature per liner table)
Download datasheet PDF

Fits water and wastewater mag metering where you need a Rosemount 8750W—magnetic flow meter aimed at water/wastewater service with standard accuracy about ±0.5% of rate and optional ±0.2% high-accuracy class.

Key advantages

  • Service — Water and wastewater
  • Accuracy — ±0.5% of rate standard; ±0.2% optional
  • Technology — Magnetic flow measurement
  • Platform — Rosemount 8750W
  • Use — Utility / municipal / industrial water

Typical applications

  • Raw / treated water lines.
  • Wastewater effluent metering.
  • Plant water balance.

Selection guide

  • Size / liner
  • Accuracy option
  • Transmitter mount

Common mistakes

  • Expecting 8700 ±0.25% class without option.
  • Non-conductive water extremes.
  • Wrong grounding rings.

When to RFQ / what to tell us

  1. Size, options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU40544
BrandRosemount
Model8750W Magnetic Flow Meter
Product typeMagnetic Flow Meter
MediumWater and wastewater
Accuracy±0.5% of rate standard; ±0.2% optional

Documents

FAQ

Q: Standard accuracy? A: ±0.5% of rate.

Q: Medium? A: Water and wastewater.

Q: What should I send for a quote? A: Size/options, quantity, ship-to.

Links

ParameterValue
AccuracyBase accuracy 0.5% of rate standard; optional high accuracy 0.2% of rate (PDS)
ApprovalsDrinking water certifications available; agency approvals per PDS ordering table
Product FamilyRosemount 8750W magnetic flow meter system for utility water/wastewater (flanged sensor + field/wall-mount transmitter)
Line Sizes½ in. to 48 in. (15 mm to 1,200 mm) flanged
Outputs4–20 mA HART; FOUNDATION Fieldbus; Modbus RS-485; EtherNet/IP; pulse; optional discrete channels
Liner MaterialsPTFE, PEX, Neoprene, Polyurethane (process temperature per liner table)
Electrode MaterialsStainless steel and nickel alloy options; standard/reference/bullet-nose electrodes
ProtectionAll-welded coil housing; sensor design rated IP68; dual-compartment transmitter housing
DiagnosticsEmpty pipe, grounding/wiring, high process noise, coated electrode, SMART Meter Verification, coil/electronics faults
PowerAC 90–250 Vac or DC supply options per transmitter selection (see PDS power tables)
ConfigurationsIntegral or remote transmitter; field-mount and wall-mount styles
ApplicationsGeneral purpose, utility, water and wastewater monitoring