Panametrics
Panametrics XMTCpro Thermal Conductivity Gas Analyzer
Quote on request
No online payment · add lines to RFQ BOM
Binary gas TC analyzer; ±2% span; dual 4–20 mA + Modbus. RFQ + selection help.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
±2% of span
Analyzer Type
Thermal conductivity binary gas analyzer (SIL 2 by design optional)
Linearity
±1% of span
Repeatability
±0.5% of span
Response Time
20 s for 90% step change
Measurement Ranges
0–1% to 0–100% and high-end spans (50–100% … 98–100%)
Fits binary gas composition measurement where you need an XMTCpro thermal-conductivity analyzer with dual isolated 4–20 mA, Modbus, and spans from 0–1% to 0–100% class.
Key advantages
- Principle — Thermal conductivity binary gas analyzer (SIL 2 by design optional)
- Accuracy — ±2% of span; linearity ±1%; repeatability ±0.5%
- Response — 20 s for 90% step change
- I/O — Two isolated 4–20 mA; Modbus RS232/RS485
- Gases — H2/He/CO2/Ar in N2/air/O2 mixes per application table
Typical applications
- Hydrogen and helium binary gas monitoring.
- Inerting and process gas composition checks.
- Sites needing Modbus plus dual mA retransmission.
Selection guide
- Span — 0–1% to 0–100% or high-end spans (50–100% … 98–100%)
- Gas pair — Confirm thermal-conductivity contrast for the binary mix
- Temperature class — Standard –20…+50 °C vs high-temp –5…+65 °C
- SIL — SIL 2 by design option if required
Common mistakes
- Applying TC binary analysis to multi-component streams without a defined binary pair.
- Ignoring sample flow window (50–2,000 cc/min; 250 cc/min nominal).
- Omitting SIL option when the loop is safety-related.
When to RFQ / what to tell us
- Gas pair and span.
- Temperature class; SIL need; Modbus/mA use.
- Quantity and ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 174225 |
| Brand | Panametrics |
| Model | XMTCpro Thermal Conductivity Binary Gas Transmitter |
| Product type | Gas Analyzer |
| Analyzer type | Thermal conductivity binary gas analyzer (SIL 2 by design optional) |
| Accuracy | ±2% of span |
| Linearity | ±1% of span |
| Repeatability | ±0.5% of span |
| Response time | 20 s for 90% step change |
| Measurement ranges | 0–1% to 0–100% and high-end spans (50–100% … 98–100%) |
| Typical gases | H2 in N2/air/O2/CO2; He in N2/air; CO2 in N2/air; Ar in N2/air |
| Sample flow | 50–2,000 cc/min (0.1–4.0 SCFH); 250 cc/min nominal |
| Analog output | Two isolated 4–20 mA, 550 Ω max load |
| Digital output | Modbus RS232/RS485 |
| Power | 24 VDC ±4 VDC, 0.8 A |
| Operating temperature | Standard –20 to +50 °C; high-temp –5 to +65 °C |
Documents
FAQ
Q: What accuracy is stated? A: ±2% of span (linearity ±1%; repeatability ±0.5%).
Q: What outputs? A: Two isolated 4–20 mA and Modbus RS232/RS485.
Q: What should I send for a quote? A: Gas pair/span, temp class, SIL, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | ±2% of span |
| Analyzer Type | Thermal conductivity binary gas analyzer (SIL 2 by design optional) |
| Linearity | ±1% of span |
| Repeatability | ±0.5% of span |
| Response Time | 20 s for 90% step change |
| Measurement Ranges | 0–1% to 0–100% and high-end spans (50–100% … 98–100%) |
| Typical Gases | H2 in N2/air/O2/CO2; He in N2/air; CO2 in N2/air; Ar in N2/air |
| Sample Flow | 50–2,000 cc/min (0.1–4.0 SCFH); 250 cc/min nominal |
| Analog Output | Two isolated 4–20 mA, 550 Ω max load |
| Digital Output | Modbus RS232/RS485 |
| Power | 24 VDC ±4 VDC, 0.8 A |
| Operating Temperature | Standard –20 to +50 °C; high-temp –5 to +65 °C |
| Enclosure | IP66 / Type 4X; Ex db IIC T6 / ATEX / IECEx options |
| Datasheet | PANA078DS Rev. 21 (06/2026) |