Key parameters
Wetted parts
316L SS, borosilicate glass, platinum, O-rings (Viton/Silicone/Ekraz)
Hazardous area
Ex d / ATEX/IECEx/cQPSus variants; SIL2 capable option
Technology
Thermal conductivity (matched thermistors / Wheatstone bridge)
Measurement Range
Selectable 0…1 % up to 0…100 %; suppressed-zero bands e.g. 50…100 % to 98…100 %
Accuracy H2 He
< ±1 % of range or ±0.05 % H₂/He (whichever greater)
Accuracy Other
< ±2 % of range (other gas mixtures/ranges)
Fits binary gas mixture analysis where you need a Michell Instruments XTC601—binary gas analyzer covering spans from 0–1% to 0–100% with suppressed high-end ranges such as 50–100% through 98–100% class configurations.
Key advantages
- Measurand — Binary gas mixture composition
- Spans — 0–1% to 0–100% class
- Suppressed — 50–100% to 98–100% class
- Form — Process binary gas analyzer
- Platform — Michell XTC601
Typical applications
- Binary mix monitoring.
- Purity / balance gas.
- Process gas quality.
Selection guide
- Gas pair
- Span
- Sample system
Common mistakes
- Wrong binary pair.
- Moisture interference.
- Unsuitable sample flow.
When to RFQ / what to tell us
- Gas pair/span.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 42637 |
| Brand | Michell Instruments |
| Model | XTC601 |
| Product type | Binary Gas Analyzer |
| Type | Binary gas analyzer (XTC601) |
| Range | 0–1% to 0–100%; 50–100% to 98–100% class spans |
| Measurement type | gas |
| Platform | Michell XTC601 |
Documents
FAQ
Q: What does it measure? A: Binary gas mixture composition.
Q: Spans? A: 0–1% to 0–100%; suppressed high ranges available.
Q: What should I send for a quote? A: Gas pair/span, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Wetted parts | 316L SS, borosilicate glass, platinum, O-rings (Viton/Silicone/Ekraz) |
| Hazardous area | Ex d / ATEX/IECEx/cQPSus variants; SIL2 capable option |
| Technology | Thermal conductivity (matched thermistors / Wheatstone bridge) |
| Measurement Range | Selectable 0…1 % up to 0…100 %; suppressed-zero bands e.g. 50…100 % to 98…100 % |
| Accuracy H2 He | < ±1 % of range or ±0.05 % H₂/He (whichever greater) |
| Accuracy Other | < ±2 % of range (other gas mixtures/ranges) |
| Repeatability | ±0.2 % of range |
| Sample Flow Gp | 100…500 ml/min (0.25…1.0 scfh) |
| Sample Flow Ex | 270…330 ml/min Ex version |
| Sample Pressure | Fixed 0.75…1.5 barA (calibrate at operating pressure); max safe 1 barg |
| Sample Gas | Non-condensing; particles <3 μm |
| Outputs | 2× 4–20 mA; Modbus RTU RS485; 2 concentration alarm relays |
| Ingress Protection | IP66 / NEMA 4 (XTC601); IP55 (XTC501) |
| Dimensions Xtc601 | 234 × 234 × 172 mm; weight 9.7 kg |
| Power | 24 V DC, 1.0 A max |