Image unavailable
Image unavailable
MRU
MRU SWG 100 Compact BioGas Analyzer
Quote on request
No online payment · add lines to RFQ BOM
MRU SWG 100: biogas/landfill; CH4/CO2 0…100%; O2; H2S; Modbus. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Application
Discontinuous biogas / landfill gas analysis; indoor or outdoor
Sites
Up to 2 sites time-shared; up to 24 measurements / 24 h user-settable
Measured Gases
O2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure)
Ch4 Co2 Range
0…100% (NDIR)
O2 Range
0…25%
Hmi
3.5 in TFT color display; password-protected calibration
Fits continuous biogas and landfill gas analysis where you need an MRU SWG 100 Compact—cabinet analyzer measuring O2, CO2, CH4 and H2S (with H2 options), CH4/CO2 0…100% NDIR, up to two time-shared sites, and 4× 4–20 mA plus RS485 Modbus RTU.
Key advantages
- Gases — O2, CO2, CH4, H2S (H2 options)
- CH4/CO2 — 0…100% NDIR
- O2 — 0…25%
- Sites — Up to 2 sites time-shared
- Outputs — 4× 4–20 mA; 2 alarm relays; RS485 Modbus RTU
Typical applications
- Biogas plants.
- Landfill gas.
- Digester monitoring.
Selection guide
- Gas sensor set
- Heated cabinet
- Site count
Common mistakes
- Wrong sample pressure band.
- Missing condensate prep.
- Ignoring H2S filter life.
When to RFQ / what to tell us
- Gas/options.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 44178 |
| Brand | MRU |
| Model | SWG 100 Compact BioGas Analyzer |
| Product type | Biogas Analyzer |
| Application | Discontinuous biogas / landfill gas analysis; indoor or outdoor |
| Measured gases | O2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure) |
| CH4/CO2 range | 0…100% (NDIR) |
| O2 range | 0…25% |
| Outputs | 4× 4…20 mA isolated; 2 alarm relays; RS485 Modbus RTU |
| Sample pressure | −100 mbar to +200 mbar inlet |
| Cabinet | 400×500×300 mm; IP54; ~14 kg |
| Power | 90…240 Vac / 47…63 Hz / 60 W (360 W with heater) |
Documents
FAQ
Q: CH4/CO2 range? A: 0…100% NDIR.
Q: Sites? A: Up to 2 time-shared.
Q: What should I send for a quote? A: Gas/options, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Application | Discontinuous biogas / landfill gas analysis; indoor or outdoor |
| Sites | Up to 2 sites time-shared; up to 24 measurements / 24 h user-settable |
| Measured Gases | O2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure) |
| Ch4 Co2 Range | 0…100% (NDIR) |
| O2 Range | 0…25% |
| Hmi | 3.5 in TFT color display; password-protected calibration |
| Outputs | 4× 4…20 mA isolated; 2 alarm relays; RS485 Modbus RTU |
| Sample Pressure | −100 mbar to +200 mbar inlet |
| Cabinet | 400×500×300 mm; IP54; ~14 kg |
| Power | 90…240 Vac / 47…63 Hz / 60 W (360 W with heater) |
| Ambient | +5…+45 °C or −10…+45 °C with cabinet heater |