MRU

MRU SWG 100 Compact BioGas Analyzer

SKU · 44178 · SWG 100 Compact BioGas Analyzer · Brand: MRU
Available
Quote on request
No online payment · add lines to RFQ BOM

MRU SWG 100: biogas/landfill; CH4/CO2 0…100%; O2; H2S; Modbus. RFQ.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Application
Discontinuous biogas / landfill gas analysis; indoor or outdoor
Sites
Up to 2 sites time-shared; up to 24 measurements / 24 h user-settable
Measured Gases
O2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure)
Ch4 Co2 Range
0…100% (NDIR)
O2 Range
0…25%
Hmi
3.5 in TFT color display; password-protected calibration
Download datasheet PDF

Fits continuous biogas and landfill gas analysis where you need an MRU SWG 100 Compact—cabinet analyzer measuring O2, CO2, CH4 and H2S (with H2 options), CH4/CO2 0…100% NDIR, up to two time-shared sites, and 4× 4–20 mA plus RS485 Modbus RTU.

Key advantages

  • Gases — O2, CO2, CH4, H2S (H2 options)
  • CH4/CO2 — 0…100% NDIR
  • O2 — 0…25%
  • Sites — Up to 2 sites time-shared
  • Outputs — 4× 4–20 mA; 2 alarm relays; RS485 Modbus RTU

Typical applications

  • Biogas plants.
  • Landfill gas.
  • Digester monitoring.

Selection guide

  • Gas sensor set
  • Heated cabinet
  • Site count

Common mistakes

  • Wrong sample pressure band.
  • Missing condensate prep.
  • Ignoring H2S filter life.

When to RFQ / what to tell us

  1. Gas/options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU44178
BrandMRU
ModelSWG 100 Compact BioGas Analyzer
Product typeBiogas Analyzer
ApplicationDiscontinuous biogas / landfill gas analysis; indoor or outdoor
Measured gasesO2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure)
CH4/CO2 range0…100% (NDIR)
O2 range0…25%
Outputs4× 4…20 mA isolated; 2 alarm relays; RS485 Modbus RTU
Sample pressure−100 mbar to +200 mbar inlet
Cabinet400×500×300 mm; IP54; ~14 kg
Power90…240 Vac / 47…63 Hz / 60 W (360 W with heater)

Documents

FAQ

Q: CH4/CO2 range? A: 0…100% NDIR.

Q: Sites? A: Up to 2 time-shared.

Q: What should I send for a quote? A: Gas/options, quantity, ship-to.

Links

ParameterValue
ApplicationDiscontinuous biogas / landfill gas analysis; indoor or outdoor
SitesUp to 2 sites time-shared; up to 24 measurements / 24 h user-settable
Measured GasesO2, CO2, CH4, H2S (low/high), H2 (NDIR / ECS per brochure)
Ch4 Co2 Range0…100% (NDIR)
O2 Range0…25%
Hmi3.5 in TFT color display; password-protected calibration
Outputs4× 4…20 mA isolated; 2 alarm relays; RS485 Modbus RTU
Sample Pressure−100 mbar to +200 mbar inlet
Cabinet400×500×300 mm; IP54; ~14 kg
Power90…240 Vac / 47…63 Hz / 60 W (360 W with heater)
Ambient+5…+45 °C or −10…+45 °C with cabinet heater