Watlow

Watlow WATROD Tubular Heater

SKU · 21697 · WATROD Tubular Heater · Brand: Watlow
Available
Quote on request
No online payment · add lines to RFQ BOM

Watlow WATROD tubular heater: immersion/air, sheath to 1800 °F class, up to 120 W/in². RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Process/sheath temperature capability: single-ended Alloy 800/840 & SS up to 1200 °F (650 °C); double-ended Alloy 800/840 up to 1600 °F (870 °C); Alloy 800 up to 1800 °F (982 °C); steel up to 750 °F (400 °C)
Accuracy
N/A (heater element; not a measuring instrument)
Output
N/A (resistive heating element)
Supply
UL/CSA recognition up to 240 VAC (single-ended) / 600 VAC (double-ended) component class
Ambient temperature
Application-dependent; silicone resin seals rated to 221 °F (105 °C) at seal
Approvals
UL; CSA
Download datasheet PDF

Fits immersion and air heating duties that need a Watlow WATROD tubular element with selectable sheath materials and watt density up to 45 W/in² (single-ended) or 120 W/in² (double-ended) per the HTR-WRDT-0221 sheet.

Key advantages

  • Sheath to 1800 °F class — Alloy 800 double-ended to 1800 °F (982 °C); single-ended SS/Alloy to 1200 °F.
  • High watt density — single-ended to 45 W/in²; double-ended to 120 W/in².
  • Material choice — steel, 304/316 SS, Alloy 800/840, Alloy 600 sheath options.
  • Optional MULTICOIL TC — internal thermocouple combinations on double-ended builds.

Typical applications

  • Immersion heating in tanks and process vessels.
  • Air and oven heating with formed tubular elements.
  • OEM builds specifying sheath alloy, watt density, and termination.

Selection guide

  • Process / sheath temperature capability — Single-ended Alloy 800/840 & SS up to 1200 °F (650 °C); double-ended Alloy 800/840 up to 1600 °F (870 °C); Alloy 800 up to 1800 °F (982 °C); steel up to 750 °F (400 °C).
  • Watt density — Single-ended up to 45 W/in² (6.9 W/cm²); double-ended up to 120 W/in² (18.6 W/cm²).
  • Sheath materials — Steel, 304/316 SS, Alloy 800/840, Alloy 600.
  • Supply — UL/CSA recognition up to 240 VAC (single-ended) / 600 VAC (double-ended) component class.
  • Sensor option — Optional MULTICOIL with internal thermocouple combinations (double-ended).
  • Seal rating — Silicone resin seals rated to 221 °F (105 °C) at seal.
  • Mounting / form — Multiple mounting and termination options; 53 standard bend formations.
  • Approvals — UL; CSA.
  • Notes — Values aligned with Watlow HTR-WRDT-0221 specification sheet. Resistive heating element — not a measuring instrument.

Common mistakes

  • Specifying steel sheath when process temperature needs Alloy 800 class (steel listed to 750 °F / 400 °C).
  • Confusing single-ended watt density (≤45 W/in²) with double-ended (≤120 W/in²).
  • Ignoring seal temperature (221 °F / 105 °C at seal) vs sheath capability.
  • Leaving bend formation / termination blank — 53 standard formations; lock geometry before RFQ.
  • Expecting a measuring accuracy line — WATROD is a heater element, not a sensor.
  • Heaters · Tubular heater buying guide

When to RFQ / what to tell us

  1. Immersion vs air duty, process/sheath temperature, medium, and single- vs double-ended preference.
  2. Sheath material, watt density target, voltage (≤240 VAC single-ended / ≤600 VAC double-ended class), MULTICOIL TC yes/no.
  3. Bend formation / mounting / termination, quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU21697
BrandWatlow
ModelWATROD Tubular Heater
Product typeheater
Process / sheath temperatureSingle-ended Alloy 800/840 & SS up to 1200 °F (650 °C); double-ended Alloy 800/840 up to 1600 °F (870 °C); Alloy 800 up to 1800 °F (982 °C); steel up to 750 °F (400 °C)
Watt densitySingle-ended up to 45 W/in² (6.9 W/cm²); double-ended up to 120 W/in² (18.6 W/cm²)
Sheath materialsSteel, 304/316 SS, Alloy 800/840, Alloy 600
Supply voltageUL/CSA recognition up to 240 VAC (single-ended) / 600 VAC (double-ended) component class
Sensor optionOptional MULTICOIL with internal thermocouple combinations (double-ended)
Seal ratingSilicone resin seals rated to 221 °F (105 °C) at seal
MountingMultiple mounting and termination options; 53 standard bend formations
ApprovalsUL; CSA
NotesValues aligned with Watlow HTR-WRDT-0221. Resistive heating element — not a measuring instrument.

Documents

FAQ

Q: Single-ended vs double-ended? A: Watt density and sheath temperature capability differ — single-ended up to 45 W/in² / 1200 °F class on Alloy 800/840 & SS; double-ended up to 120 W/in² with higher Alloy 800 class limits. Lock the style on the RFQ.

Q: Does it measure temperature? A: No — it is a resistive heater. Optional MULTICOIL internal thermocouple is available on double-ended configurations.

Q: What should I send for a quote? A: Duty, temperature, medium, sheath, watt density, voltage, bend/termination, quantity. Compatible with systems using Watlow WATROD tubular heaters — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangeProcess/sheath temperature capability: single-ended Alloy 800/840 & SS up to 1200 °F (650 °C); double-ended Alloy 800/840 up to 1600 °F (870 °C); Alloy 800 up to 1800 °F (982 °C); steel up to 750 °F (400 °C)
AccuracyN/A (heater element; not a measuring instrument)
OutputN/A (resistive heating element)
SupplyUL/CSA recognition up to 240 VAC (single-ended) / 600 VAC (double-ended) component class
Ambient temperatureApplication-dependent; silicone resin seals rated to 221 °F (105 °C) at seal
ApprovalsUL; CSA
MountingMultiple mounting and termination options; 53 standard bend formations
Sensor typeOptional MULTICOIL with internal thermocouple combinations (double-ended)
NotesWATROD tubular heaters for immersion and air heating. Specs from Watlow HTR-WRDT-0221 specification sheet.
Watt DensitySingle-ended up to 45 W/in² (6.9 W/cm²); double-ended up to 120 W/in² (18.6 W/cm²)
Sheath MaterialsSteel, 304/316 SS, Alloy 800/840, Alloy 600