E+E HUMOR 20 Humidity Calibrator

SKU · 43289 · E+E HUMOR 20 Humidity Calibrator
Available
Quote on request
No online payment · add lines to RFQ BOM

E+E HUMOR 20: dual-pressure RH calibrator 10–95 %RH, 0.3–0.9 %RH. RFQ + selection help.

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Range
—
Accuracy
—
Output
—

Portable dual-pressure humidity generator for lab and field reference work — 10…95 %RH working range, OEM accuracy band 0.3…0.9 %RH, stabilisation under 3 minutes per point, independent of ambient temperature, needs only distilled water, clean oil-free air to 10 bar, and 90…230 V AC.

Key advantages

  • Primary dual-pressure principle — generated RH depends on pressure; suitable as a humidity reference.
  • 10…95 %RH — accuracy 0.3…0.9 %RH (OEM product page); stabilisation <3 min/point.
  • Probe flexibility — chamber covers for Ø8…25.5 mm probes; up to four devices; room-mount sensors and loggers.
  • Four measuring inputs — switchable 4–20 / 0–20 mA or 0–1 / 0–5 / 0–10 V; 24 V DC specimen supply.
  • Auto calibration option — Automatic Calibration Module + PC software for multi-point cycles and certificates.

Typical applications

  • Calibration laboratories needing a portable RH reference.
  • Manufacturers of humidity sensors and transmitters.
  • On-site multi-point RH verification with distilled-water operation.
  • Accredited calibration workflows (optional accredited certificate).

Selection guide

  • Working range — 10…95 %RH; chamber temperature measurement accuracy typ. ±0.3 °C.
  • Air / water — filtered oil-free air max 10 bar (particles >0.1 µm, residual oil <0.01 mg/m³); distilled water only.
  • Supply — 90…230 V AC (datasheet also states 100–230 V AC, 50/60 Hz, max 20 W).
  • Covers / capacity — metal covers preferred for stated accuracy; compact specimens up to ~100×85×40 mm.
  • Certificates — DIN EN 10204-3.1 inspection certificate standard; accredited points on request (e.g. 15/55/90 %RH).
  • Auto kit — optional Automatic Calibration Module for unattended cycles.

Common mistakes

  • Filling tap water — OEM requires distilled water only.
  • Transporting with water at tilt >20° — drain first if tilt cannot be assured.
  • Expecting accuracy without the correct metal chamber cover.
  • Using unfiltered oily shop air — residual oil/particles damage regulators.

When to RFQ / what to tell us

  1. Standard unit vs Automatic Calibration Module.
  2. Chamber covers needed (probe diameters); accredited certificate points.
  3. Quantity and ship-to country.
  4. Any specimen supply / input scaling notes.

Request a Quote · Get selection help

Specs

SpecValue
SKU43289
BrandE+E Elektronik
ModelHUMOR 20
Product typeDual-pressure humidity calibrator / generator
Operating range10…95 %RH
Accuracy (generated RH)0.3…0.9 %RH (OEM product page)
Stabilisation time<3 min per measuring point
ChamberProbes Ø8…25.5 mm (0.3…1 in); up to four devices
Air supplyClean oil-free air to 10 bar (145 psi)
Supply voltage90…230 V AC (100–230 V AC, 50/60 Hz per datasheet)
ProtectionIP40
NotesSpecs from epluse.com HUMOR 20 page and datasheet_Humor20.pdf. Confirm cover/auto-kit before order.

Documents

FAQ

Q: What certificate ships standard? A: Inspection certificate per DIN EN 10204-3.1. Accredited multi-point certificates are optional — request on RFQ.

Q: Does ambient temperature affect RH? A: By design the dual-pressure principle is independent of ambient temperature in the stated operating window.

Q: What should I send for a quote? A: Auto-kit need, covers/probe diameters, certificate type, quantity, ship-to. Compatible with systems using E+E HUMOR 20 if you need a drop-in check — we do not claim authorized-dealer status.