Image unavailable
Image unavailable
E+E Elektronik
E+E EE210 Humidity and Temperature Transmitter
Quote on request
No online payment · add lines to RFQ BOM
EE210: RH/T transmitter; wall/duct; 0–100 %RH; −40…60 °C class. RFQ.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Mounting
Wall (T1), duct (T2), remote probe (T3), outdoor with radiation shield (T13)
Type
Humidity and temperature sensor/transmitter for demanding climate control (EE210)
Humidity Range
0…100 %RH
Humidity Accuracy
Type T1/T2: ±(1.3 + 0.003×mv) %RH (−15…+40 °C, ≤90 %RH)
Temperature Range
−40…+60 °C (−40…+140 °F) typical wall/duct
Outputs
Analogue voltage/current (2 channels) + RS485 Modbus RTU; optional display
Fits HVAC and controlled-space RH/T sensing where you need an E+E Elektronik EE210—humidity and temperature transmitter for wall or duct mounting with 0–100 %RH and −40…60 °C class spans and analog / digital output options per OEM configuration.
Key advantages
- Measurands — Relative humidity and temperature
- RH span — 0–100 %RH class
- Temperature — −40…60 °C class
- Mount — Wall or duct versions
- Platform — E+E EE210
Typical applications
- HVAC humidity control.
- Cleanroom / storage RH.
- Building automation sensors.
Selection guide
- Wall vs duct
- Output type
- Filter / probe length
Common mistakes
- Condensing without filter care.
- Wrong duct insertion.
- Ignoring calibration interval.
When to RFQ / what to tell us
- Mount/output code.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 42596 |
| Brand | E+E Elektronik |
| Model | EE210 |
| Product type | Humidity Transmitter |
| Type | Humidity and temperature sensor/transmitter for demanding climate control (EE210) |
| Humidity range | 0…100 %RH |
| Humidity accuracy | Type T1/T2: ±(1.3 + 0.003×mv) %RH (−15…+40 °C, ≤90 %RH) |
| Temperature range | −40…+60 °C (−40…+140 °F) typical wall/duct |
| Outputs | Analogue voltage/current (2 channels) + RS485 Modbus RTU; optional display |
| Mounting | Wall (T1), duct (T2), remote probe (T3), outdoor with radiation shield (T13) |
Documents
FAQ
Q: What does it measure? A: Relative humidity and temperature.
Q: Mount styles? A: Wall and duct versions.
Q: What should I send for a quote? A: Mount/output, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Mounting | Wall (T1), duct (T2), remote probe (T3), outdoor with radiation shield (T13) |
| Type | Humidity and temperature sensor/transmitter for demanding climate control (EE210) |
| Humidity Range | 0…100 %RH |
| Humidity Accuracy | Type T1/T2: ±(1.3 + 0.003×mv) %RH (−15…+40 °C, ≤90 %RH) |
| Temperature Range | −40…+60 °C (−40…+140 °F) typical wall/duct |
| Outputs | Analogue voltage/current (2 channels) + RS485 Modbus RTU; optional display |
| Calculated | Dew point, absolute humidity, mixing ratio and related RH parameters |
| Enclosure | IP65 / NEMA 4X |
| Sensing | Encapsulated electronics + E+E coated sensing element for polluted/corrosive air |
| Configuration | Optional USB-C stick for interface, scaling, RH/T adjustment, display layout |