Key parameters

Display
4.6×3.4 in (116×86 mm) 320×240 LCD graphical UI
Type
Programmable digital weight indicator / controller (920i Series)
Power
AC 100–240 VAC 50/60 Hz; DC 12–24 VDC; AC 25 W (universal) or 65 W; DC 25 W
Excitation
10 VDC (±5 VDC); 16×350 Ω or 32×700 Ω load cells per A/D card
Analog Input
−45 mV to +45 mV; sensitivity 0.3 µV/grad min (1.0 µV/grad recommended)
Ad Sample Rate
7.5 to 960 Hz, software selectable
Download datasheet PDF

Fits programmable scale control where you need a Rice Lake 920i. Digital weight indicator/controller with −45 to +45 mV analog input, A/D sample rate 7.5–960 Hz, internal resolution 8,000,000 counts, 10 VDC excitation for up to 16×350 Ω load cells per A/D card, on AC or DC power.

Key advantages

  • A/D — 7.5–960 Hz software selectable
  • Resolution — Internal 8,000,000 counts
  • Excitation — 10 VDC; 16×350 Ω per A/D card
  • Input — −45 to +45 mV
  • Power — 100–240 VAC or 12–24 VDC

Typical applications

  • Batching / filling control.
  • Truck / floor scale indicators.
  • Programmable weight I/O.

Selection guide

  • A/D cards
  • Program options
  • AC vs DC

Common mistakes

  • Too many cells per card.
  • Sensitivity below 0.3 µV/grad.
  • Wrong power option.

When to RFQ / what to tell us

  1. Cards/options.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU46939
BrandRice Lake Weighing Systems
Model920i
Product typeWeight Indicator
TypeProgrammable digital weight indicator / controller (920i Series)
PowerAC 100–240 VAC 50/60 Hz; DC 12–24 VDC; AC 25 W (universal) or 65 W; DC 25 W
Excitation10 VDC (±5 VDC); 16×350 Ω or 32×700 Ω load cells per A/D card
Analog input−45 mV to +45 mV; sensitivity 0.3 µV/grad min (1.0 µV/grad recommended)
A/D sample rate7.5 to 960 Hz, software selectable
ResolutionInternal 8,000,000 counts; display 1,000,000

Documents

FAQ

Q: Sample rate? A: 7.5–960 Hz.

Q: Excitation? A: 10 VDC.

Q: What should I send for a quote? A: Cards/options, quantity, ship-to.

Links

ParameterValue
Display4.6×3.4 in (116×86 mm) 320×240 LCD graphical UI
TypeProgrammable digital weight indicator / controller (920i Series)
PowerAC 100–240 VAC 50/60 Hz; DC 12–24 VDC; AC 25 W (universal) or 65 W; DC 25 W
Excitation10 VDC (±5 VDC); 16×350 Ω or 32×700 Ω load cells per A/D card
Analog Input−45 mV to +45 mV; sensitivity 0.3 µV/grad min (1.0 µV/grad recommended)
Ad Sample Rate7.5 to 960 Hz, software selectable
ResolutionInternal 8,000,000 counts; display 1,000,000
Linearity±0.01% full scale
CommsFour serial ports on CPU (RS-232/RS-485/20 mA/USB options) up to 115200 bps
DocumentRice Lake 920i Series datasheet / operator manual