Fluke 1587 FC Insulation Multimeter
Insulation multimeter for megohm + DMM checks. 0.01 MΩ–2 GΩ at 50–1000 V, CAT III 1000 V / CAT IV 600 V. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits field insulation and basic electrical troubleshooting when you need selectable megohm test voltages plus a True-RMS DMM in one handheld, with Fluke Connect logging — not a fixed-panel insulation monitor.
Key advantages
- Insulation + DMM — Megohm tests 0.01 MΩ–2 GΩ at 50/100/250/500/1000 V plus True-RMS DMM functions in one handheld.
- CAT III 1000 V / CAT IV 600 V — IEC 61010 category marks for industrial distribution work.
- Live-circuit inhibit — Insulation test blocked if >30 V is present.
- Fluke Connect — Wireless PI/DAR, memory, and temperature-compensation workflows via the app.
Typical applications
- Motor and cable insulation checks with selectable test voltages.
- Field troubleshooting that needs insulation plus voltage/mA/ohms/capacitance/temperature in one tool.
- Teams documenting insulation trends over Fluke Connect.
Selection guide
- Insulation range / test voltages — 0.01 MΩ–2 GΩ at 50 / 100 / 250 / 500 / 1000 V. Match test voltage to the insulation class under test.
- DMM ranges — Voltage to 1000 V AC/DC; mA to 400 mA; ohms to 50 MΩ; capacitance to 9999 μF; temperature −40…537 °C.
- Accuracy — Insulation typically ±(1.5% + 5) to ±(3% + 5) depending on test voltage/range; DMM V DC ±(0.09% + 2).
- Safety category — CAT III 1000 V / CAT IV 600 V (IEC 61010-1, IEC 61010-2-033).
- Live-circuit inhibit — Insulation test inhibited if >30 V present.
- Communication — Fluke Connect wireless (PI/DAR, memory, temperature compensation via app); FCC T68-FBLE.
- Supply — Four AA batteries (IEC LR6).
- IP / ambient — IP40 (IEC 60529, non-operating); operating −20…+55 °C; storage −40…+60 °C.
- Size / weight — 5.0×10.0×20.3 cm; 550 g.
Common mistakes
- Using a low test voltage (50/100 V) on equipment that needs 500/1000 V insulation stress — pick voltage from the insulation class, not habit.
- Expecting IP40 to cover outdoor wet use — rating is non-operating per IEC 60529; plan enclosure/handling accordingly.
- Ignoring live-circuit inhibit: if >30 V is present, insulation test will not run until the circuit is clear.
- Treating Fluke Connect features (PI/DAR, temp compensation) as available without the app/wireless path confirmed on site.
- Assuming CAT III 1000 V / CAT IV 600 V covers every panel bus — verify the measurement location against the category.
When to RFQ / what to tell us
- Primary use: insulation test voltages needed vs DMM-only work.
- Typical circuits (voltage class) and whether CAT III 1000 V / CAT IV 600 V is sufficient.
- Need for Fluke Connect / PI-DAR logging yes/no.
- Temperature measurement requirement (−40…537 °C range on unit).
- Quantity, ship-to country, and any required marks (IEC 61010, FCC) to match site policy.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 42407 |
| Brand | Fluke |
| Model | 1587 FC |
| Product type | other (insulation multimeter) |
| Measuring range | Insulation 0.01 MΩ–2 GΩ at 50/100/250/500/1000 V; DMM to 1000 V AC/DC; mA to 400 mA; ohms to 50 MΩ; capacitance to 9999 μF; temperature −40…537 °C |
| Accuracy | Insulation typically ±(1.5% + 5) to ±(3% + 5) depending on test voltage/range; DMM V DC ±(0.09% + 2) |
| Output / features | Insulation test voltages 50/100/250/500/1000 V; Fluke Connect wireless |
| Supply | Four AA batteries (IEC LR6) |
| IP rating | IP40 (IEC 60529, non-operating) |
| Ambient temperature | Operating −20…+55 °C; storage −40…+60 °C |
| Communication | Fluke Connect (PI/DAR, memory, temperature compensation via app) |
| Approvals | CAT III 1000 V; CAT IV 600 V; IEC 61010-1; IEC 61010-2-033; FCC T68-FBLE |
| Weight | 550 g |
| Notes | Size 5.0×10.0×20.3 cm. Live circuit detection inhibits insulation test if >30 V present. |
Documents
FAQ
Q: Insulation tester or full DMM — what does 1587 FC cover? A: Both in one handheld: insulation 0.01 MΩ–2 GΩ at 50–1000 V test voltages, plus DMM functions to 1000 V AC/DC, mA, ohms, capacitance, and temperature. State which functions you will use daily in the RFQ.
Q: Will it test insulation on a live circuit? A: No — live-circuit detection inhibits the insulation test if >30 V is present. De-energize and verify before megohm testing.
Q: Which safety marks apply? A: Datasheet lists CAT III 1000 V, CAT IV 600 V, IEC 61010-1, IEC 61010-2-033, and FCC T68-FBLE. Match the measurement location to the category before use.
Q: What should I send for a quote? A: Required test voltages, CAT needs, Fluke Connect yes/no, quantity, ship-to. Compatible with systems using Fluke 1587 FC if you need a drop-in check — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Insulation 0.01 MΩ–2 GΩ at 50/100/250/500/1000 V; DMM to 1000 V AC/DC; mA to 400 mA; ohms to 50 MΩ; capacitance to 9999 μF; temperature −40…537 °C |
| Accuracy | Insulation typically ±(1.5% + 5) to ±(3% + 5) depending on test voltage/range; DMM V DC ±(0.09% + 2) |
| Output | Insulation test voltages 50/100/250/500/1000 V; Fluke Connect wireless |
| Supply | Four AA batteries (IEC LR6) |
| Protection | IP40 (IEC 60529, non-operating) |
| Ambient temperature | Operating −20…+55 °C; storage −40…+60 °C |
| Communication | Fluke Connect (PI/DAR, memory, temperature compensation via app) |
| Approvals | CAT III 1000 V; CAT IV 600 V; IEC 61010-1; IEC 61010-2-033; FCC T68-FBLE |
| Notes | Size 5.0×10.0×20.3 cm. Live circuit detection inhibits insulation test if >30 V present. |
| Weight | 550 g |