Keller LevelRat Level Transmitter
Submersible level transmitter 0…5 to 0…100 ftWC, ±0.25 %FS, 4–20 mA/V + optional RS485. IP68. RFQ + selection help.
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Fits submersible liquid-level loops that need a relative range between 0…5 and 0…100 ftWC with 4–20 mA or voltage output, optional RS485, IP68 cable probe construction, and optional UL/cUL intrinsically safe builds.
Key advantages
- Custom relative ranges — infinite between 0…5 and 0…100 ftWC (psi / inWC / ftWC).
- Static ±0.25 %FS — Total Error Band ±0.5 %BR in the compensated range.
- Output mix — 4–20 mA IS; 4–20 mA + RS485; 0–5 / 0–10 VDC + RS485.
- Kynar non-fouling diaphragm option — 316L std / titanium optional; IP68 submersible cable probe.
Typical applications
- Wastewater and lift-station level with non-fouling diaphragm needs.
- Tank and reservoir level where ranges are specified in ftWC.
- IS-approved 4–20 mA level loops in classified sumps.
Selection guide
- Range — Relative infinite between 0…5 and 0…100 ft WC (psi / inWC / ftWC custom). Basic ranges 1 and 3 bar relative (proof 2 and 5 bar).
- Accuracy — Static ±0.25 %FS; Total Error Band ±0.5 %BR (compensated range).
- Output — 4–20 mA IS-approved; 4–20 mA + RS485 (with/without lightning protection); 0–5 / 0–10 VDC + RS485.
- Supply — 11…30 VDC (4–20 mA IS); 11…32 VDC (4–20 mA+RS485 w/ LP); 8…32 VDC (4–20 mA+RS485 w/o LP / 0–5 V); 13…32 VDC (0–10 V).
- Process / electrical — Submersible cable probe; optional 1/2" NPT conduit fitting accessory. Integral cable (PE/EPDM, Hytrel/Viton, or Tefzel options); braided shield to housing.
- Wetted / housing — 316L stainless steel standard; optional titanium; Kynar non-fouling diaphragm; cable seals PE/EPDM or Hytrel/Viton/Tefzel.
- Ingress — IP68.
- Ambient — Operating −10…60 °C; compensated 0…50 °C.
Common mistakes
- Ordering a span outside 0…5 to 0…100 ftWC without confirming custom engineering with the RFQ.
- Mixing IS vs non-IS supply windows (11…30 VDC IS vs wider non-IS windows) and cable barrier requirements.
- Ignoring cable seal chemistry (PE/EPDM vs Hytrel/Viton vs Tefzel) vs process media.
- Assuming a local display — this SKU lists display: none.
- Expecting a published media-temperature row from this page — that field is empty in our JSON; send process temperature in the RFQ.
- Skipping lightning-protection option when the site has surge exposure on long cable runs.
When to RFQ / what to tell us
- Level span (ftWC / psi / inWC) and fluid SG if converting head to pressure.
- Output (4–20 mA IS / 4–20 mA+RS485 / voltage+RS485) and whether lightning protection is required.
- Cable length, seal material, and optional 1/2" NPT conduit fitting / weight / spacer.
- Housing material (316L vs titanium) and diaphragm (standard vs Kynar).
- Area classification (UL/cUL IS yes/no), quantity, ship-to country.
- Process/media temperature (not published as a separate JSON field — state it on the RFQ).
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 33971 |
| Brand | Keller |
| Model | LevelRat |
| Product type | level_transmitter |
| Measuring range | Relative infinite between 0…5 and 0…100 ft WC (custom units) |
| Accuracy | Static ±0.25 %FS; TEB ±0.5 %BR (compensated) |
| Output signal | 4–20 mA IS; 4–20 mA + RS485 (± lightning protection); 0–5 / 0–10 VDC + RS485 |
| Supply voltage | 11…30 VDC (4–20 mA IS); 11…32 / 8…32 / 13…32 VDC by output option |
| Process connection | Submersible cable probe; optional 1/2" NPT conduit fitting |
| Electrical connection | Integral cable (PE/EPDM, Hytrel/Viton, or Tefzel); braided shield |
| Wetted materials | 316L SS std; optional titanium; Kynar non-fouling diaphragm |
| Housing | 316L stainless (optional titanium) |
| IP rating | IP68 |
| Ambient | Operating −10…60 °C; compensated 0…50 °C |
| Process pressure | Relative to 100 ftWC; basic 1 and 3 bar relative (proof 2 and 5 bar) |
| Communication | Optional RS485 KELLER-bus / Modbus RTU (up to 128 nodes) |
| Display | none |
| Hazardous area | UL/cUL IS versions available (4–20 mA IS) |
| Approvals | CE; UL/cUL Class I Div 1 A–D; Class II Div 1 E–G; Class III (4–20 mA IS) |
| Mounting | Submersible; optional protective spacer / stabilizing weight |
| Notes | Specs from Keller LevelRat datasheet Edition 06/2026. Lightning protection lifetime guarantee on 4–20 mA models. |
Documents
- Keller LevelRat datasheet (PDF) — request the current OEM PDF on RFQ (no direct public PDF URL stored for this SKU).
FAQ
Q: What level ranges are available? A: Relative ranges infinitely configurable between 0…5 and 0…100 ftWC (psi / inWC / ftWC custom). State the span in the RFQ.
Q: Which outputs and IS options exist? A: 4–20 mA IS-approved; 4–20 mA + RS485 with/without lightning protection; 0–5 / 0–10 VDC + RS485. UL/cUL IS applies to the 4–20 mA IS builds listed in the datasheet.
Q: Is there a local display? A: No — display is listed as none. Readout is via the loop / RS485 host.
Q: What should I send for a quote? A: Span, output, cable/seal, material, IS need, process temperature, quantity, ship-to. Compatible with systems using Keller LevelRat — we do not claim authorized-dealer status.
Links
| Parameter | Value |
|---|---|
| Measuring range | Relative infinite between 0…5 and 0…100 ft WC (psi / inWC / ftWC custom) |
| Accuracy | Static ±0.25 %FS; Total Error Band ±0.5 %BR (compensated range) |
| Accuracy % FS | 0.25 |
| Output | 4–20 mA IS-approved; 4–20 mA + RS485 (with/without lightning protection); 0–5 / 0–10 VDC + RS485 |
| Supply | 11…30 VDC (4–20 mA IS); 11…32 VDC (4–20 mA+RS485 w/ LP); 8…32 VDC (4–20 mA+RS485 w/o LP / 0–5 V); 13…32 VDC (0–10 V) |
| Process connection | Submersible cable probe; optional 1/2" NPT conduit fitting accessory |
| Electrical connection | Integral cable (PE/EPDM, Hytrel/Viton, or Tefzel options); braided shield to housing |
| Wetted parts | 316L stainless steel standard; optional titanium; Kynar non-fouling diaphragm; cable seals PE/EPDM or Hytrel/Viton/Tefzel |
| Housing | 316L stainless (optional titanium) |
| Protection | IP68 |
| Ambient temperature | Operating −10…60 °C; compensated 0…50 °C |
| Display | none |
| Communication | Optional RS485 KELLER-bus / Modbus RTU (up to 128 nodes) |
| Approvals | CE (EN 61000-6-1…6-4 / EN 61326-1 / EN 61326-2-3); UL/cUL Class I Div 1 Groups A–D; Class II Div 1 Groups E–G; Class III (4–20 mA IS) |
| Hazardous area | UL/cUL intrinsically safe versions available |
| Mounting | Submersible; optional protective spacer / stabilizing weight |
| Notes | Specs from Keller LevelRat datasheet Edition 06/2026. Lightning protection lifetime guarantee on 4–20 mA models. |
| Process Pressure | Relative level ranges to 100 ftWC; basic ranges 1 and 3 bar relative (proof 2 and 5 bar) |