Keller

Keller LevelRat Level Transmitter

SKU · 33971 · LevelRat · Brand: Keller
Available
Quote on request
No online payment · add lines to RFQ BOM

Submersible level transmitter 0…5 to 0…100 ftWC, ±0.25 %FS, 4–20 mA/V + optional RS485. IP68. RFQ + selection help.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Measuring range
Relative infinite between 0…5 and 0…100 ft WC (psi / inWC / ftWC custom)
Accuracy
Static ±0.25 %FS; Total Error Band ±0.5 %BR (compensated range)
Accuracy % FS
0.25
Output
4–20 mA IS-approved; 4–20 mA + RS485 (with/without lightning protection); 0–5 / 0–10 VDC + RS485
Supply
11…30 VDC (4–20 mA IS); 11…32 VDC (4–20 mA+RS485 w/ LP); 8…32 VDC (4–20 mA+RS485 w/o LP / 0–5 V); 13…32 VDC (0–10 V)
Process connection
Submersible cable probe; optional 1/2" NPT conduit fitting accessory
Download datasheet PDF

Fits submersible liquid-level loops that need a relative range between 0…5 and 0…100 ftWC with 4–20 mA or voltage output, optional RS485, IP68 cable probe construction, and optional UL/cUL intrinsically safe builds.

Key advantages

  • Custom relative ranges — infinite between 0…5 and 0…100 ftWC (psi / inWC / ftWC).
  • Static ±0.25 %FS — Total Error Band ±0.5 %BR in the compensated range.
  • Output mix — 4–20 mA IS; 4–20 mA + RS485; 0–5 / 0–10 VDC + RS485.
  • Kynar non-fouling diaphragm option — 316L std / titanium optional; IP68 submersible cable probe.

Typical applications

  • Wastewater and lift-station level with non-fouling diaphragm needs.
  • Tank and reservoir level where ranges are specified in ftWC.
  • IS-approved 4–20 mA level loops in classified sumps.

Selection guide

  • Range — Relative infinite between 0…5 and 0…100 ft WC (psi / inWC / ftWC custom). Basic ranges 1 and 3 bar relative (proof 2 and 5 bar).
  • Accuracy — Static ±0.25 %FS; Total Error Band ±0.5 %BR (compensated range).
  • Output — 4–20 mA IS-approved; 4–20 mA + RS485 (with/without lightning protection); 0–5 / 0–10 VDC + RS485.
  • Supply — 11…30 VDC (4–20 mA IS); 11…32 VDC (4–20 mA+RS485 w/ LP); 8…32 VDC (4–20 mA+RS485 w/o LP / 0–5 V); 13…32 VDC (0–10 V).
  • Process / electrical — Submersible cable probe; optional 1/2" NPT conduit fitting accessory. Integral cable (PE/EPDM, Hytrel/Viton, or Tefzel options); braided shield to housing.
  • Wetted / housing — 316L stainless steel standard; optional titanium; Kynar non-fouling diaphragm; cable seals PE/EPDM or Hytrel/Viton/Tefzel.
  • Ingress — IP68.
  • Ambient — Operating −10…60 °C; compensated 0…50 °C.

Common mistakes

  • Ordering a span outside 0…5 to 0…100 ftWC without confirming custom engineering with the RFQ.
  • Mixing IS vs non-IS supply windows (11…30 VDC IS vs wider non-IS windows) and cable barrier requirements.
  • Ignoring cable seal chemistry (PE/EPDM vs Hytrel/Viton vs Tefzel) vs process media.
  • Assuming a local display — this SKU lists display: none.
  • Expecting a published media-temperature row from this page — that field is empty in our JSON; send process temperature in the RFQ.
  • Skipping lightning-protection option when the site has surge exposure on long cable runs.

When to RFQ / what to tell us

  1. Level span (ftWC / psi / inWC) and fluid SG if converting head to pressure.
  2. Output (4–20 mA IS / 4–20 mA+RS485 / voltage+RS485) and whether lightning protection is required.
  3. Cable length, seal material, and optional 1/2" NPT conduit fitting / weight / spacer.
  4. Housing material (316L vs titanium) and diaphragm (standard vs Kynar).
  5. Area classification (UL/cUL IS yes/no), quantity, ship-to country.
  6. Process/media temperature (not published as a separate JSON field — state it on the RFQ).

Request a Quote · Get selection help

Specs

SpecValue
SKU33971
BrandKeller
ModelLevelRat
Product typelevel_transmitter
Measuring rangeRelative infinite between 0…5 and 0…100 ft WC (custom units)
AccuracyStatic ±0.25 %FS; TEB ±0.5 %BR (compensated)
Output signal4–20 mA IS; 4–20 mA + RS485 (± lightning protection); 0–5 / 0–10 VDC + RS485
Supply voltage11…30 VDC (4–20 mA IS); 11…32 / 8…32 / 13…32 VDC by output option
Process connectionSubmersible cable probe; optional 1/2" NPT conduit fitting
Electrical connectionIntegral cable (PE/EPDM, Hytrel/Viton, or Tefzel); braided shield
Wetted materials316L SS std; optional titanium; Kynar non-fouling diaphragm
Housing316L stainless (optional titanium)
IP ratingIP68
AmbientOperating −10…60 °C; compensated 0…50 °C
Process pressureRelative to 100 ftWC; basic 1 and 3 bar relative (proof 2 and 5 bar)
CommunicationOptional RS485 KELLER-bus / Modbus RTU (up to 128 nodes)
Displaynone
Hazardous areaUL/cUL IS versions available (4–20 mA IS)
ApprovalsCE; UL/cUL Class I Div 1 A–D; Class II Div 1 E–G; Class III (4–20 mA IS)
MountingSubmersible; optional protective spacer / stabilizing weight
NotesSpecs from Keller LevelRat datasheet Edition 06/2026. Lightning protection lifetime guarantee on 4–20 mA models.

Documents

  • Keller LevelRat datasheet (PDF) — request the current OEM PDF on RFQ (no direct public PDF URL stored for this SKU).

FAQ

Q: What level ranges are available? A: Relative ranges infinitely configurable between 0…5 and 0…100 ftWC (psi / inWC / ftWC custom). State the span in the RFQ.

Q: Which outputs and IS options exist? A: 4–20 mA IS-approved; 4–20 mA + RS485 with/without lightning protection; 0–5 / 0–10 VDC + RS485. UL/cUL IS applies to the 4–20 mA IS builds listed in the datasheet.

Q: Is there a local display? A: No — display is listed as none. Readout is via the loop / RS485 host.

Q: What should I send for a quote? A: Span, output, cable/seal, material, IS need, process temperature, quantity, ship-to. Compatible with systems using Keller LevelRat — we do not claim authorized-dealer status.

Links

ParameterValue
Measuring rangeRelative infinite between 0…5 and 0…100 ft WC (psi / inWC / ftWC custom)
AccuracyStatic ±0.25 %FS; Total Error Band ±0.5 %BR (compensated range)
Accuracy % FS0.25
Output4–20 mA IS-approved; 4–20 mA + RS485 (with/without lightning protection); 0–5 / 0–10 VDC + RS485
Supply11…30 VDC (4–20 mA IS); 11…32 VDC (4–20 mA+RS485 w/ LP); 8…32 VDC (4–20 mA+RS485 w/o LP / 0–5 V); 13…32 VDC (0–10 V)
Process connectionSubmersible cable probe; optional 1/2" NPT conduit fitting accessory
Electrical connectionIntegral cable (PE/EPDM, Hytrel/Viton, or Tefzel options); braided shield to housing
Wetted parts316L stainless steel standard; optional titanium; Kynar non-fouling diaphragm; cable seals PE/EPDM or Hytrel/Viton/Tefzel
Housing316L stainless (optional titanium)
ProtectionIP68
Ambient temperatureOperating −10…60 °C; compensated 0…50 °C
Displaynone
CommunicationOptional RS485 KELLER-bus / Modbus RTU (up to 128 nodes)
ApprovalsCE (EN 61000-6-1…6-4 / EN 61326-1 / EN 61326-2-3); UL/cUL Class I Div 1 Groups A–D; Class II Div 1 Groups E–G; Class III (4–20 mA IS)
Hazardous areaUL/cUL intrinsically safe versions available
MountingSubmersible; optional protective spacer / stabilizing weight
NotesSpecs from Keller LevelRat datasheet Edition 06/2026. Lightning protection lifetime guarantee on 4–20 mA models.
Process PressureRelative level ranges to 100 ftWC; basic ranges 1 and 3 bar relative (proof 2 and 5 bar)