FMX21 HART hydrostatic: 100 mbar–20 bar; ±0.2%/±0.1%; IP68 probe. RFQ cable.

Download datasheet PDF

RFQ cart holds BOM lines only. Submit for engineering quote.

Key parameters

Accuracy
Reference ±0.2%; PLATINUM ±0.1%
Approvals
Drinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV
Type
Hydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21)
Oem Note
Pipeline label FMX24 — no public FMX24 page; OEM current Waterpilot hydrostatic probe is FMX21
Pressure Range
100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O
Process Temperature
−10…+70 °C (29 mm saltwater version 0…+50 °C)
Download datasheet PDF

Fits HART-enabled hydrostatic level where you need Endress+Hauser Waterpilot FMX21 with 4–20 mA HART 6.0—ceramic cell to 20 bar and fresh/waste/saltwater probe diameters.

Key advantages

  • Protocol — 4–20 mA HART 6.0
  • Accuracy — ±0.2% reference; ±0.1% Platinum
  • Range — 100 mbar…20 bar (~200 m H₂O)
  • Cell — Oil-free ceramic
  • Media kits — Fresh / waste / saltwater diameters

Typical applications

  • SCADA HART level loops.
  • Municipal water level.
  • Coastal saltwater probing.

Selection guide

  • HART host / DD needs
  • Medium diameter
  • Cable / venting
  • Approvals

Common mistakes

  • Assuming a legacy FMX16x order code without remapping to FMX21.
  • Under-sizing cable for well depth.
  • Mixing drinking-water and wastewater materials.

When to RFQ / what to tell us

  1. Order code intent, cable, HART.
  2. Quantity, ship-to.

Request a Quote · Get selection help

Specs

SpecValue
SKU33979
BrandEndress+Hauser
ModelWaterpilot FMX21
Product typeHydrostatic Level Transmitter
TypeHydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21)
AccuracyReference ±0.2%; PLATINUM ±0.1%
Pressure range100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O
Process temperature−10…+70 °C (29 mm saltwater version 0…+50 °C)
Output4–20 mA with HART 6.0; optional integrated Pt100 temperature
Versions22 mm drinking water; 42 mm wastewater; 29 mm saltwater/marine
Wetted parts316L / ceramic / seals; plastic insulation on saltwater version; PE/PUR/FEP cable
ApprovalsDrinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV

Documents

FAQ

Q: Is this FMX21? A: Yes — OEM model is Waterpilot FMX21.

Q: HART version? A: HART 6.0 on the 4–20 mA output.

Q: What should I send for a quote? A: Cable/version, quantity, ship-to.

Links

ParameterValue
AccuracyReference ±0.2%; PLATINUM ±0.1%
ApprovalsDrinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV
TypeHydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21)
Oem NotePipeline label FMX24 — no public FMX24 page; OEM current Waterpilot hydrostatic probe is FMX21
Pressure Range100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O
Process Temperature−10…+70 °C (29 mm saltwater version 0…+50 °C)
Versions22 mm drinking water; 42 mm wastewater; 29 mm saltwater/marine
Wetted Parts316L / ceramic / seals; plastic insulation on saltwater version; PE/PUR/FEP cable
ApplicationWells/boreholes, tanks, wastewater, ballast water, environmental monitoring
DocumentTI00431PEN Technical Information + BA00380PEN Operating Instructions
DesignPotted electronics; 2-filter pressure compensation; overload-resistant ceramic