Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Waterpilot FMX21 Wastewater Probe
Quote on request
No online payment · add lines to RFQ BOM
FMX21 wastewater hydrostatic: 42 mm class; ceramic cell; 4–20 mA HART. RFQ cable.
Download datasheet PDF
RFQ cart holds BOM lines only. Submit for engineering quote.
Key parameters
Accuracy
Reference ±0.2%; PLATINUM ±0.1%
Approvals
Drinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV
Type
Hydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21)
Oem Note
Pipeline label FMX16 — no public FMX16 product page; OEM current Waterpilot hydrostatic probe is FMX21 (predecessors FMX160/FMX167 discontinued)
Pressure Range
100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O
Process Temperature
−10…+70 °C (29 mm saltwater version 0…+50 °C)
Fits wastewater and sludge-tolerant hydrostatic level where you need Endress+Hauser Waterpilot FMX21—typically 42 mm diameter class ceramic probe with 4–20 mA HART.
Key advantages
- Duty — Wastewater hydrostatic probing
- Diameter class — 42 mm wastewater versions
- Accuracy — ±0.2% / ±0.1% Platinum
- Range — To 20 bar / ~200 m H₂O
- Output — 4–20 mA HART 6.0
Typical applications
- Wet-well level.
- Lift-station sumps.
- Municipal wastewater tanks.
Selection guide
- 42 mm wastewater kit
- Cable armor / strain relief
- Ex if classified
- Span vs well depth
Common mistakes
- Forcing a 22 mm freshwater probe into solids-laden wastewater.
- Unsupported cable abrasion.
- Ignoring coating/build-up on the ceramic face.
When to RFQ / what to tell us
- Wastewater version, cable, Ex.
- Quantity, ship-to.
Request a Quote · Get selection help
Specs
| Spec | Value |
|---|---|
| SKU | 33981 |
| Brand | Endress+Hauser |
| Model | Waterpilot FMX21 |
| Product type | Hydrostatic Level Transmitter |
| Type | Hydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21) |
| Accuracy | Reference ±0.2%; PLATINUM ±0.1% |
| Pressure range | 100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O |
| Process temperature | −10…+70 °C (29 mm saltwater version 0…+50 °C) |
| Output | 4–20 mA with HART 6.0; optional integrated Pt100 temperature |
| Versions | 22 mm drinking water; 42 mm wastewater; 29 mm saltwater/marine |
| Wetted parts | 316L / ceramic / seals; plastic insulation on saltwater version; PE/PUR/FEP cable |
| Approvals | Drinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV |
Documents
FAQ
Q: Wastewater diameter? A: 42 mm class for wastewater FMX21 versions.
Q: Cell type? A: Oil-free ceramic measuring cell.
Q: What should I send for a quote? A: Version/cable/Ex, quantity, ship-to.
Links
| Parameter | Value |
|---|---|
| Accuracy | Reference ±0.2%; PLATINUM ±0.1% |
| Approvals | Drinking water KTW/NSF/ACS; ATEX/FM/CSA; marine GL/ABS/BV/DNV |
| Type | Hydrostatic level probe with oil-free ceramic measuring cell (Waterpilot FMX21) |
| Oem Note | Pipeline label FMX16 — no public FMX16 product page; OEM current Waterpilot hydrostatic probe is FMX21 (predecessors FMX160/FMX167 discontinued) |
| Pressure Range | 100 mbar…20 bar (1.5…300 psi); max distance ~200 m H2O |
| Process Temperature | −10…+70 °C (29 mm saltwater version 0…+50 °C) |
| Versions | 22 mm drinking water; 42 mm wastewater; 29 mm saltwater/marine |
| Wetted Parts | 316L / ceramic / seals; plastic insulation on saltwater version; PE/PUR/FEP cable |
| Application | Wells/boreholes, tanks, wastewater, ballast water, environmental monitoring |
| Document | TI00431PEN Technical Information + BA00380PEN Operating Instructions |
| Design | Potted electronics; 2-filter pressure compensation; overload-resistant ceramic |